In Vitro Comparison of Several Thrombus Removal Tools

被引:2
作者
Pigon, Katarzyna [1 ]
Tomecka, Natalia [2 ]
Korner, Dominika [3 ]
Pekala, Maciej [2 ]
Grzegorczyn, Slawomir [4 ]
Konka, Adam [3 ]
Nowalany-Kozielska, Ewa [1 ]
Tomasik, Andrzej [1 ]
机构
[1] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol Zabrze 2, PL-40055 Katowice, Poland
[2] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, Students Sci Grp, PL-40055 Katowice, Poland
[3] Kardiomed Silesia, PL-41800 Zabrze, Poland
[4] Med Univ Silesia, Fac Med Sci Zabrze, Dept Biophys, PL-40055 Katowice, Poland
关键词
thrombus; aspiration thrombectomy; mechanical thrombectomy; aspiration catheters; stentriever; ELEVATION MYOCARDIAL-INFARCTION; PERCUTANEOUS CORONARY INTERVENTION; LONG-TERM MORTALITY; DISTAL EMBOLIZATION; PRIMARY ANGIOPLASTY; THROMBECTOMY; ASPIRATION; STENT; CATHETER; ASSOCIATION;
D O I
10.3390/jcdd10020069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although the routine use of thrombus aspiration is not recommended, the thrombectomy technique still might be considered for a selected population of patients. Therefore, the assessment of the effectiveness of commercially available thrombectomy devices is still clinically relevant. Aim: Here, we present an in vitro comparison of several different types of catheters that can be used for thrombus aspiration or removal. Methods: Through the removal of 6 h and 24 h human blood clots in an in vitro model, four catheters were compared: the Launcher, Pronto V4, Vasco+ and the stent-retriever Catchview. The aspiration efficacy was expressed as a percentage of the initial thrombus weight. The effectiveness of the patient's aspiration was dependent on the time of thrombus formation and was significantly higher for a thrombus formed over 24 h (58.5 +/- 26.5%) than for one formed over 6 h (48.0 +/- 22.5%; p < 0.001). In the presented in vitro model, Pronto V4 and Launcher showed the highest efficiency. Conclusions: Large-bore aspiration catheters were found to be more effective than narrow-bore catheters or stent-retrievers in an in vitro model of thrombus removal. The thrombus aspiration efficacy increases with longer thrombus formation times.
引用
收藏
页数:9
相关论文
共 38 条
  • [1] Culprit lesion thrombus burden after manual thrombectomy or percutaneous coronary intervention-alone in ST-segment elevation myocardial infarction: the optical coherence tomography sub-study of the TOTAL (ThrOmbecTomy versus PCI ALone) trial
    Bhindi, Ravinay
    Kajander, Olli A.
    Jolly, Sanjit S.
    Kassam, Saleem
    Lavi, Shahar
    Niemela, Kari
    Fung, Anthony
    Cheema, Asim N.
    Meeks, Brandi
    Alexopoulos, Dimitrios
    Kocka, Viktor
    Cantor, Warren J.
    Kaivosoja, Timo P.
    Shestakovska, Olga
    Gao, Peggy
    Stankovic, Goran
    Dzavik, Vladimir
    Sheth, Tej
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 (29) : 1892 - 1900
  • [2] Successful extraction of refractory thrombus from an ectatic coronary artery using stent retriever during primary angioplasty for acute myocardial infarction: a case report
    Bhoopalan, Kesavamoorthy
    Rajendran, Ravindran
    Alagarsamy, Srinivasan
    Kesavamoorthy, Niranjana
    [J]. EUROPEAN HEART JOURNAL-CASE REPORTS, 2019, 3 (01)
  • [3] Understanding and managing in-stent restenosis: a review of clinical data, from pathogenesis to treatment
    Buccheri, Dario
    Piraino, Davide
    Andolina, Giuseppe
    Cortese, Bernardo
    [J]. JOURNAL OF THORACIC DISEASE, 2016, 8 (10) : E1150 - E1162
  • [4] Time-dependent benefit of initial thrombosuction on myocardial reperfusion in primary percutaneous coronary intervention
    Chao, C. -L.
    Hung, C. -S.
    Lin, Y. -H.
    Lin, M. -S.
    Lin, L. -C.
    Ho, Y. -L.
    Liu, C. -P.
    Chiang, C. -H.
    Kao, H. -L.
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2008, 62 (04) : 555 - 561
  • [5] Mechanical thrombectomy: Stent retrievers vs. aspiration catheters
    Fanous, Andrew A.
    Siddiqui, Adnan H.
    [J]. COR ET VASA, 2016, 58 (02) : E193 - E203
  • [6] Thrombus Aspiration during ST-Segment Elevation Myocardial Infarction
    Frobert, Ole
    Lagerqvist, Bo
    Olivecrona, Goran K.
    Omerovic, Elmir
    Gudnason, Thorarinn
    Maeng, Michael
    Aasa, Mikael
    Angeras, Oskar
    Calais, Fredrik
    Danielewicz, Mikael
    Erlinge, David
    Hellsten, Lars
    Jensen, Ulf
    Johansson, Agneta C.
    Karegren, Amra
    Nilsson, Johan
    Robertson, Lotta
    Sandhall, Lennart
    Sjogren, Iwar
    Ostlund, Ollie
    Harnek, Jan
    James, Stefan K.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (17) : 1587 - 1597
  • [7] Mechanisms of disease: Mechanisms of thrombus formation
    Furie, Bruce
    Furie, Barbara C.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (09) : 938 - 949
  • [8] Girish MP, 2012, J INVASIVE CARDIOL, V24, P141
  • [9] Hara Hisao, 2007, EuroIntervention, V2, P487
  • [10] Incidence and clinical significance of distal embolization during primary angioplasty for acute myocardial infarction
    Henriques, JPS
    Zijlstra, F
    Ottervanger, JP
    de Boer, MJ
    van't Hof, AWJ
    Hoorntje, JCA
    Suryapranata, H
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 (14) : 1112 - 1117