Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience

被引:0
作者
Sawaddisan, Rapphon [1 ]
Khwankaew, Noppasin [1 ]
Pruksanusak, Ninlapa [1 ]
Suntharasaj, Thitima [1 ]
Suwanrath, Chikasaem [1 ]
Pranpanus, Savitree [1 ]
Petpichetchian, Chusana [1 ]
Suksai, Manaphat [1 ]
Chainarong, Natthicha [1 ]
机构
[1] Prince Songkla Univ, Fac Med, Dept Obstet & Gynecol, Hat Yai 90110, Songkhla, Thailand
关键词
cervical elastography; pelvic parameters; reliability; term pregnancy; HEAD-SYMPHYSIS DISTANCE; LABOR INDUCTION SUCCESS; UTERINE CERVIX; TRANSPERINEAL ULTRASOUND; DIAGNOSTIC-ACCURACY; BISHOP SCORE; PREDICTION; AGREEMENT; STATION; ANGLE;
D O I
10.1002/ijgo.15363
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
ObjectiveTo assess the reliability of sonographic measurements of six cervical and pelvic parameters by three sonographers with varying levels of experience.MethodsA cross-sectional study was conducted in pregnant women with a gestational age of >= 39 weeks. Each pregnant woman was examined by two sonographers with different levels of experience. Six parameters were measured: cervical length (CL), cervical strain elastography (extrinsic type), posterior cervical angle (PCA), fetal head-to-perineum distance (FHPD), fetal head-to-pubic symphysis distance (FHSD), and angle of progression (AOP). Intra- and interobserver reliabilities were assessed using the intraclass correlation coefficient with a 95% confidence interval. Pearson pairwise correlation coefficients were used to analyze the correlation between the parameter values.ResultsIn all, 66 pregnant women were enrolled in this study. We found excellent intraobserver reliability for measurements of CL, PCA, FHPD, FHSD, and AOP and good-to-excellent intraobserver reliability for cervical strain values in the cross-sectional view of the endocervix in the internal os area and cross-sectional view of the entire cervix in the internal os area. Interobserver reliability was excellent for all pelvic parameters, except for the FHPD. Strain values were moderate to excellent in the area of the internal os. A significant negative correlation between CL and strain values at the internal os was observed.ConclusionsPelvic parameters, except for FHPD, have excellent intra- and interobserver reliabilities. The high reproducibility of CL and cervical strain elastography at the internal os level, with a negative correlation between these two parameters, may play an important role in predicting successful induction of labor.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 35 条
  • [1] Aggarwal K., 2019, INT J REPROD CONTRAC, V8, P628
  • [2] Diagnostic accuracy of posterior cervical angle and cervical length in the prediction of successful induction of labor
    Al-Adwy, Akram M.
    Sobh, Sherin M.
    Belal, Doaa S.
    Omran, Eman F.
    Hassan, Amr
    Saad, Ahmed H.
    Afifi, Mai M.
    Nada, Adel M.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2018, 141 (01) : 102 - 107
  • [3] The validity of ultrasonography in predicting the outcomes of labour induction
    Alvarez-Colomo, Cristina
    Alberto Gobernado-Tejedor, Julio
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2016, 293 (02) : 311 - 316
  • [4] A new method to assess fetal head descent in labor with transperineal ultrasound
    Barbera, A. F.
    Pombar, X.
    Perugino, G.
    Lezotte, D. C.
    Hobbins, J. C.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (03) : 313 - 319
  • [5] BISHOP EH, 1964, OBSTET GYNECOL, V24, P266
  • [6] Celik HG., 2018, INT J REPROD CONTRAC, V7, P2998
  • [7] Pre-Induction Transperineal Ultrasound Assessment for the Prediction of Labor Outcome
    Chan, Winnie W. Y.
    Chaemsaithong, Piya
    Lim, Wen Teng
    Tse, Ada W. T.
    Kwan, Angel H. W.
    Leung, Tak Yeung
    Sahota, Daljit S.
    Poon, Liona C.
    [J]. FETAL DIAGNOSIS AND THERAPY, 2019, 45 (04) : 256 - 267
  • [8] Ultrasound assessment of fetal head-perineum distance before induction of labor
    Eggebo, T. M.
    Heien, C.
    Okland, I.
    Gjessing, L. K.
    Romundstad, P.
    Salvesen, K. A.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (02) : 199 - 204
  • [9] Prediction of labor and delivery by transperineal ultrasound in pregnancies with prelabor rupture of membranes at term
    Eggebo, TM
    Gjessing, LK
    Heien, C
    Smedvig, E
    Okland, I
    Romundstad, P
    Salvesen, KA
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (04) : 387 - 391
  • [10] Can ultrasound measurements replace digitally assessed elements of the Bishop score?
    Eggebo, Torbjorn M.
    Okland, Inger
    Heien, Claudia
    Gjessing, Leif K.
    Romundstad, Pal
    Salvesen, Kjell A.
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2009, 88 (03) : 325 - 331