Effect Mechanism of Ambient Air Parameters on the Thermal Performance for Cooling Towers

被引:3
|
作者
Zhang, Lei [1 ]
Zhou, Jun [1 ]
Zuo, Simeng [1 ]
An, Guangyao [1 ]
Lang, Jinhua [1 ]
Yuan, Wei [1 ]
机构
[1] North China Elect Power Univ, Dept Power Engn, Baoding 071003, Hebei, Peoples R China
关键词
natural draft wet cooling tower; ambient air parameters; thermal performance; numerical simulation; evaporation; heat and mass transfer; ROTATING STALL; VENTILATION;
D O I
10.1115/1.4063875
中图分类号
O414.1 [热力学];
学科分类号
摘要
As the volume of natural draft wet cooling towers (NDWCTs) continues to increase, the influence of ambient air on the thermal performance of the NDWCT is not clear. Therefore, the main parameters such as gas-water ratio, circulating water temperature difference, and heat transfer in each zone were calculated, and the temperature field and humidity field were also investigated. The results showed that the ambient temperature had the greatest influence on the cooling capacity of the NDWCT and the increase of ambient temperature led the circulating water temperature difference decreases the most, which was 7.63 degree celsius (74.15%). The increase of relative humidity and atmospheric pressure led to an increase in convective heat transfer and the decrease in evaporative mass transfer, while both the convective heat transfer and evaporative mass transfer reduced with the decreasing temperature. This study establishes a theoretical foundation for optimizing of the thermal performance and energy-saving design of NDWCTs.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Influence of three different pitches fillings on the cooling performance of wet cooling towers under crosswind
    Yang, Jichong
    Jia, Zhenguo
    Guan, Hongjun
    He, Suoying
    Gao, Ming
    APPLIED THERMAL ENGINEERING, 2023, 220
  • [32] Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup
    Alavi, Seyed Rashid
    Rahmati, Mehdi
    ENERGY CONVERSION AND MANAGEMENT, 2016, 122 : 504 - 514
  • [33] Influence mechanism of the louver on the thermal performance of the mechanical draft wet cooling tower
    Deng, Weipeng
    Sun, Fengzhong
    Wang, Runchen
    He, Keting
    APPLIED THERMAL ENGINEERING, 2023, 230
  • [34] Proposing a new technique to enhance thermal performance and reduce structural design wind loads for natural drought cooling towers
    Goudarzi, Mohammad Ali
    ENERGY, 2013, 62 : 164 - 172
  • [35] Experimental investigation on the performance of wet cooling towers with defects in power plants
    Ning, Tao
    Chong, Daotong
    Jia, Mingxiao
    Wang, Jinshi
    Yan, Junjie
    APPLIED THERMAL ENGINEERING, 2015, 78 : 228 - 235
  • [36] Machine learning-based optimization and performance analysis of cooling towers
    Salins, Sampath Suranjan
    Kumar, Shiva
    Ganesha, A.
    Reddy, S. V. Kota
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [37] Economic and technical assessment of the desiccant wheel effect on the thermal performance of cross flow cooling towers in variable wet bulb temperature
    Salem Banooni
    Ali Chitsazan
    Heat and Mass Transfer, 2014, 50 : 1587 - 1596
  • [38] Development of a hybrid model for reliably predicting the thermal performance of direct contact countercurrent cooling towers
    Jayaweera, Chamanthi
    Groot, Niels
    Meul, Steven
    Verliefde, Arne
    Nopens, Ingmar
    Hitsov, Ivaylo
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 197
  • [39] Windbreak walls reverse the negative effect of crosswind in short natural draft dry cooling towers into a performance enhancement
    Lu, Y.
    Guan, Z.
    Gurgenci, H.
    Zou, Z.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 63 : 162 - 170
  • [40] Passive cooling and thermal comfort performance of Passive Downdraught Evaporative Cooling (PDEC) towers in a Saudi library: An on-site study
    Alshenaifi, Mohammad A.
    Mesloub, Abdelhakim
    Alfraidi, Sultan
    Noaime, Emad
    Ahriz, Atef
    Sharples, Steve
    BUILDING AND ENVIRONMENT, 2024, 258