Locking compression plate fixation in humeral shaft fractures: A comparative study to literature conservative treatment

被引:7
作者
Capitani, P. [1 ,2 ]
Chiodini, F. [3 ]
Di Mento, L. [2 ]
Cavanna, M. [2 ]
Bove, F. [1 ]
Capitani, D. [1 ]
Berlusconi, M. [2 ]
机构
[1] ASST GOM Niguarda, Dept Orthoped Surg & Traumatol, Milan, Italy
[2] Humanitas Clin & Res Ctr, Trauma Unit, Milan, Italy
[3] Osped Legnano, ASST Ovest Milanese, Dept Orthoped & Traumatol, Legnano, Italy
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2023年 / 54卷
关键词
Humeral shaft fracture; Plate; LCP; Conservative; Function; Radial nerve palsy; Non union; Review; RADIAL NERVE PALSY; DIAPHYSEAL FRACTURES; FUNCTIONAL TREATMENT; INTRAMEDULLARY NAIL; OPERATIVE TREATMENT; MANAGEMENT; OUTCOMES;
D O I
10.1016/j.injury.2021.03.027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Humeral shaft fractures represent about 3% of all fractures. While there are several treatment options for this type of fractures, there is no evidence in literature showing which is the best one. This study aims at analysing the outcomes for patients with humeral shaft fractures treated with Locking Compression Plate (LCP) fixation in our hospital and comparing them with the outcome for patients conservatively treated (according to data from Pubmed), in order to determine the best treatment option. Materials and Methods: We treated surgically 220 humeral shaft fractures in our department from February 2005 to March 2012. Seventy-three of them met all the inclusion criteria for this study. All fractures were then classified according to the AO classification. The follow-up considered the radiographic healing of the fracture. All patients were treated with plate fixation (LCP - DePuySynthes Co). At the end of the four-year follow-up, the function was evaluated by means of the DASH score. A systematic review of the literature of the last 20 years was performed on MEDLINE (PubMed). Results: We had 2 infections and 8 patients had postoperative nerve palsy which recovered in average time of 6.7 months. In addition, 4 fractures (5.48%) didn't heal within 6 months and they were considered as nonunions and healed after a second surgery. One of these 4 nonunions was infected. The mean DASH score was 18.24 +/- 19.18. No malunions were found. We identified 13 studies that were eligible for our systematic review. The mean non-union rate found was 17% in 2517 fractures with a follow-up that ranging from 67% to 100% of patients and a primary radial nerve palsy ranging from 0 to 115 patients. Malalignment rate ranged from 12.7 to 42%. Conclusions: After taking into account both the conservative and the surgical treatment, for humeral shaft fractures we suggest the operative treatment, because the patient's function of the upper limb recovers quickly in the immediate postoperative period and the incidence of malunions may be avoided. (c) 2021 Published by Elsevier Ltd.
引用
收藏
页码:S2 / S8
页数:7
相关论文
共 47 条
[1]   Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique [J].
An, Zhiquan ;
Zeng, Bingfang ;
He, Xiaojian ;
Chen, Qi ;
Hu, Shundong .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) :131-135
[2]   Compression plating versus intramedullary nailing of humeral shaft fractures - a meta-analysis [J].
Bhandari, Mohit ;
Devereaux, P. J. ;
McKee, Michael D. ;
Schemitsch, Emil H. .
ACTA ORTHOPAEDICA, 2006, 77 (02) :279-284
[3]   Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS) [J].
Brunner, Alexander ;
Thormann, Sebastian ;
Babst, Reto .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (08) :1056-1063
[4]  
Buckley R., 2018, AO principles of fracture treatment. 3ed
[5]   Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study [J].
Changulani, M. ;
Jain, U. K. ;
Keswani, Tulsi .
INTERNATIONAL ORTHOPAEDICS, 2007, 31 (03) :391-395
[6]   Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates [J].
Chapman, JR ;
Henley, MB ;
Agel, J ;
Benca, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (03) :162-166
[7]   A lifelong story: Case report of a humeral shaft nonunion successfully treated after 30 years [J].
De Carolis, O. ;
Mori, C. M. ;
Vicenti, G. ;
Carrozzo, M. ;
Abate, A. ;
Caiaffa, V. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 :S43-S47
[8]  
Denard Antony Jr, 2010, Orthopedics, V33, DOI 10.3928/01477447-20100625-16
[9]  
Dielwart Cassandra, 2017, J Orthop Trauma, V31, P220, DOI 10.1097/BOT.0000000000000768
[10]   Fractures of the shaft of the humerus -: An epidemiological study of 401 fractures [J].
Ekholm, R. ;
Adami, J. ;
Tidermark, J. ;
Hansson, K. ;
Tornkvist, H. ;
Ponzer, S. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (11) :1469-1473