Effectiveness of Optimal Shared Multiple Tuned Mass Damper Inerters for Pounding Mitigation of Adjacent Buildings

被引:12
|
作者
Djerouni, Salah [1 ,2 ]
Elias, Said [3 ]
Abdeddaim, Mahdi [1 ]
De Domenico, Dario [4 ]
机构
[1] Mohamed Khider Univ, Fac Sci & Technol, Dept Civil Engineeringand Hydraul, LARGHYDE Lab, BP 145 RP, Biskra 07000, Algeria
[2] Univ Iceland, Fac Civil & Environm Engn, Earthquake Engn Res Ctr, Sch Engn & Nat Sci, Austurvegur 2a, IS-800 Selfoss, Iceland
[3] Univ Twente UTWENTE, Fac Engn Technol ET, Dept Construct Management & Engn CME, NL-7500 Twente, Netherlands
[4] Univ Messina, Dept Engn, Contrada Di Dio,Villaggio S Agata, I-98166 Messina, Italy
关键词
Adjacent buildings; Pounding risk; Inerter; Tuned mass damper inerter (TMDI); Particle swarm optimization; Tuned inerter damper (TID); Seismic response control; VIBRATION CONTROL; DESIGN; OPTIMIZATION; SYSTEMS;
D O I
10.1061/(ASCE)SC.1943-5576.0000732
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Pounding between adjacent buildings subjected to ground motion excitation is one of the most dangerous phenomena for building safety. In this paper, three novel configurations are proposed (two of them are uncoupled, and one of them is coupled), and two different passive devices are used, namely, tuned mass damper inerter (TMDI) and tuned inerter damper (TID). In addition, the proposed configurations are investigated for pounding mitigation. To determine the devices' optimum parameters (mass, inertance, stiffness, and damping), a particle swarm optimization algorithm is used. The objective function is set to minimize the peak of the frequency response functions of interstory drift. The proposed configurations are compared with the best existing configuration in the literature. A large set of ground motion records is used to illustrate the efficiency of the proposed configurations. Based on the results, it is found that the proposed uncoupled configurations by using TMDIs or TIDs perform better than the existing configuration in the literature.
引用
收藏
页数:20
相关论文
共 50 条
  • [11] Study on a multiple pounding tuned rotary mass damper and its damping performance
    Li S.-J.
    Fan P.-R.
    Kong F.
    Zhang Y.-J.
    Wang L.-C.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2023, 36 (03): : 796 - 803
  • [12] Proposed robust tuned mass damper for response mitigation in buildings exposed to multidirectional wind
    Aly, Aly Mousaad
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2014, 23 (09) : 664 - 691
  • [13] Experimental studies on the effectiveness and robustness of a pounding tuned mass damper for vibration suppression of a submerged cylindrical pipe
    Jiang, Jinwei
    Zhang, Peng
    Patil, Devendra
    Li, Hong-nan
    Song, Gangbing
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (12)
  • [14] Seismic Vibration Mitigation of a Cable-Stayed Bridge with Asymmetric Pounding Tuned Mass Damper
    Zhang, Peng
    Tan, Jie
    Liu, Haitao
    Yang, Gang
    Cui, Chunyi
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [15] Pounding tuned mass damper with constrained layer damping
    Duan, Yaoyao
    Huo, Linsheng
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (11) : 2110 - 2122
  • [16] Numerical modeling and experimental study on a novel pounding tuned mass damper
    Wang, Wenxi
    Hua, Xugang
    Wang, Xiuyong
    Chen, Zhengqing
    Song, Gangbing
    JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (17) : 4023 - 4036
  • [17] Optimum tuned mass damper design for preventing brittle fracture of RC buildings
    Nigdeli, Sinan Melih
    Bekdas, Gebrail
    SMART STRUCTURES AND SYSTEMS, 2013, 12 (02) : 137 - 155
  • [18] Vibration Control of a Pipeline Structure Using Pounding Tuned Mass Damper
    Song, G. B.
    Zhang, P.
    Li, L. Y.
    Singla, M.
    Patil, D.
    Li, H. N.
    Mo, Y. L.
    JOURNAL OF ENGINEERING MECHANICS, 2016, 142 (06)
  • [19] Inerter-Connected Double Tuned Mass Damper for Passive Control of Buildings under Seismic Excitation
    Jalali, Himan Hojat
    Farzam, Maziar Fahimi
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (02): : 421 - 432
  • [20] Closed-form optimal design of the tuned inerter damper (TID) connecting adjacent flexible buildings
    Zhang, Zili
    Li, Xiang
    Chen, Bei
    Hua, Xugang
    ENGINEERING STRUCTURES, 2024, 302