CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer

被引:1
|
作者
Luu, Huan Minh [1 ]
Yoo, Gyu Sang [2 ]
Park, Won [3 ,5 ]
Park, Sung-Hong [1 ,4 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon, South Korea
[2] Chungbuk Natl Univ Hosp, Dept Radiat Oncol, Cheongju, South Korea
[3] Samsung Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] Korea Adv Inst Sci & Technol KAIST, Dept Bio & Brain Engn, Rm 1002,CMS E16 Bldg,291 Daehak Ro, Daejeon 34141, South Korea
[5] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Dept Radiat Oncol, Seoul 06351, South Korea
基金
新加坡国家研究基金会;
关键词
CycleSeg; deep learning; prostate; radiotherapy treatment planning; synthetic CT; unsupervised domain adaptation; AUTO-SEGMENTATION; IMAGE; VOLUMES; DELINEATION; ORGANS; TUMOR; RISK;
D O I
10.1002/mp.16976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMR-only radiotherapy treatment planning is an attractive alternative to conventional workflow, reducing scan time and ionizing radiation. It is crucial to derive the electron density map or synthetic CT (sCT) from MR data to perform dose calculations to enable MR-only treatment planning. Automatic segmentation of relevant organs in MR images can accelerate the process by preventing the time-consuming manual contouring step. However, the segmentation label is available only for CT data in many cases.PurposeWe propose CycleSeg, a unified framework that generates sCT and corresponding segmentation from MR images without access to MR segmentation labelsMethodsCycleSeg utilizes the CycleGAN formulation to perform unpaired synthesis of sCT and image alignment. To enable MR (sCT) segmentation, CycleSeg incorporates unsupervised domain adaptation by using a pseudo-labeling approach with feature alignment in semantic segmentation space. In contrast to previous approaches that perform segmentation on MR data, CycleSeg could perform segmentation on both MR and sCT. Experiments were performed with data from prostate cancer patients, with 78/7/10 subjects in the training/validation/test sets, respectively.ResultsCycleSeg showed the best sCT generation results, with the lowest mean absolute error of 102.2 and the lowest Frechet inception distance of 13.0. CycleSeg also performed best on MR segmentation, with the highest average dice score of 81.0 and 81.1 for MR and sCT segmentation, respectively. Ablation experiments confirmed the contribution of the proposed components of CycleSeg.ConclusionCycleSeg effectively synthesized CT and performed segmentation on MR images of prostate cancer patients. Thus, CycleSeg has the potential to expedite MR-only radiotherapy treatment planning, reducing the prescribed scans and manual segmentation effort, and increasing throughput.
引用
收藏
页码:4365 / 4379
页数:15
相关论文
共 50 条
  • [21] Dosimetric evaluation of an atlas-based synthetic CT generation approach for MR-only radiotherapy of pelvis anatomy
    Farjam, Reza
    Tyag, Neelam
    Deasy, Joseph O.
    Hun, Margie A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 101 - 109
  • [22] Dosimetric evaluation of synthetic CT image generated using a neural network for MR-only brain radiotherapy
    Tang, Bin
    Wu, Fan
    Fu, Yuchuan
    Wang, Xianliang
    Wang, Pei
    Orlandini, Lucia Clara
    Li, Jie
    Hou, Qing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 55 - 62
  • [23] Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy
    Olberg, Sven
    Zhang, Hao
    Kennedy, William R.
    Chun, Jaehee
    Rodriguez, Vivian
    Zoberi, Imran
    Thomas, Maria A.
    Kim, Jin Sung
    Mutic, Sasa
    Green, Olga L.
    Park, Justin C.
    MEDICAL PHYSICS, 2019, 46 (09) : 4135 - 4147
  • [24] Generation of abdominal synthetic CTs from 0.35T MR images using generative adversarial networks for MR-only liver radiotherapy
    Fu, Jie
    Singhrao, Kamal
    Cao, Minsong
    Yu, Victoria
    Santhanam, Anand P.
    Yang, Yingli
    Guo, Minghao
    Raldow, Ann C.
    Ruan, Dan
    Lewis, John H.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (01):
  • [25] SARU: A self-attention ResUNet to generate synthetic CT images for MR-only BNCT treatment planning
    Zhao, Sheng
    Geng, Changran
    Guo, Chang
    Tian, Feng
    Tang, Xiaobin
    MEDICAL PHYSICS, 2023, 50 (01) : 117 - 127
  • [26] Clinical validation of MR imaging time reduction for substitute/synthetic CT generation for prostate MRI-only treatment planning
    Tony Young
    Jason Dowling
    Robba Rai
    Gary Liney
    Peter Greer
    David Thwaites
    Lois Holloway
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1015 - 1021
  • [27] Clinical validation of MR imaging time reduction for substitute/synthetic CT generation for prostate MRI-only treatment planning
    Young, Tony
    Dowling, Jason
    Rai, Robba
    Liney, Gary
    Greer, Peter
    Thwaites, David
    Holloway, Lois
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (03) : 1015 - 1021
  • [28] Clinical evaluation of autonomous, unsupervised planning integrated in MR-guided radiotherapy for prostate cancer
    Kuenzel, Luise A.
    Nachbar, Marcel
    Hagmueller, Markus
    Gani, Cihan
    Boeke, Simon
    Wegener, Daniel
    Paulsen, Frank
    Zips, Daniel
    Thorwarth, Daniela
    RADIOTHERAPY AND ONCOLOGY, 2022, 168 : 229 - 233
  • [29] Abdominal synthetic CT generation for MR-only radiotherapy using structure-conserving loss and transformer-based cycle-GAN
    Lee, Chanwoong
    Yoon, Young Hun
    Sung, Jiwon
    Kim, Jun Won
    Cho, Yeona
    Kim, Jihun
    Chun, Jaehee
    Kim, Jin Sung
    FRONTIERS IN ONCOLOGY, 2025, 14
  • [30] Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer
    Hsu, Shu-Hui
    Han, Zhaohui
    Leeman, Jonathan E.
    Hu, Yue-Houng
    Mak, Raymond H.
    Sudhyadhom, Atchar
    FRONTIERS IN ONCOLOGY, 2022, 12