Use of two point-of-care analyzers provides reference intervals of prothrombin time and activated partial prothrombin time in nonanesthetized healthy ferrets (Mustela putorius furo)

被引:0
|
作者
Bernhard, Cecile [1 ]
Linsart, Adeline [2 ]
Larrat, Sylvain [3 ]
Mentre, Veronique [1 ]
机构
[1] Vet Clin Arche NAC, Pontoise, France
[2] Ctr Hosp Vet St Martin, Allonzier La Caille, France
[3] Vet Clin Benjamin Franklin, Brech, France
来源
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION | 2023年 / 261卷 / 05期
关键词
COAGULATION; ANESTHESIA;
D O I
10.2460/javma.22.12.0595
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE Coagulation tests are an essential tool in the diagnosis and management of coagulopathies in mammals. The aim of the current study was to establish reference intervals for prothrombin time (PT) and activated partial PT (aPTT) in healthy ferrets using 2 different point-of-care analyzers (Idexx Coag DX and MS QuickVet Coag Combo).ANIMALS 86 clinically healthy ferrets under 3 years of age (47 females and 39 males) from 4 breeders and 2 private practices.PROCEDURES Blood samples were collected from the cranial vena cava in all ferrets without anesthesia and placed in trisodium 3.2% citrated plastic tubes. Sixty-six blood samples from the 4 ferret breeding farms and 1 private practice were analyzed using the Idexx Coag DX and 21 from the other private practice using the MS QuickVet Coag Combo.RESULTS Reference intervals for the Idexx Coag DX were as follows: aPTT (n = 65), 69.84 to 105.99 seconds; PT (65), 14.44 to 21.98 seconds. Reference intervals for the MS QuickVet Coag Combo were as follows: aPTT (n = 21), 74.90 to 115.50 seconds; PT (21), 18.31 to 23.05 seconds. With both types of analyzers, there was no significant age effect on aPTT and PT.CLINICAL RELEVANCE This study provided coagulation times for 2 point-of-care analyzers in healthy ferrets as a tool for the diagnosis of coagulopathies.
引用
收藏
页码:713 / 717
页数:5
相关论文
共 22 条
  • [1] Agreement of point-of-care prothrombin and activated partial thromboplastin time in dogs with a reference laboratory
    Yang, W.
    Hosgood, G.
    Luobikis, K.
    Paul, A.
    AUSTRALIAN VETERINARY JOURNAL, 2018, 96 (10) : 379 - 384
  • [2] Impact of telavancin on prothrombin time and activated partial thromboplastin time as determined using point-of-care coagulometers
    Michael P. Ero
    Nathaniel R. Harvey
    Jack L. Harbert
    James W. Janc
    Kay H. Chin
    Steven L. Barriere
    Journal of Thrombosis and Thrombolysis, 2014, 38 : 235 - 240
  • [3] Impact of telavancin on prothrombin time and activated partial thromboplastin time as determined using point-of-care coagulometers
    Ero, Michael P.
    Harvey, Nathaniel R.
    Harbert, Jack L.
    Janc, James W.
    Chin, Kay H.
    Barriere, Steven L.
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2014, 38 (02) : 235 - 240
  • [4] Evaluation of a point-of-care coagulation analyzer for measurement of prothrombin time, activated partial thromboplastin time, and activated clotting time in dogs
    Tseng, LW
    Hughes, D
    Giger, U
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (09) : 1455 - 1460
  • [5] Verification and Establishment of Reference Intervals for Prothrombin Time and Activated Partial Thromboplastin Time for Children in a Clinical Laboratory
    Lee, Min Young
    Lee, Woo In
    Kang, So Young
    Kim, Myeong Hee
    CLINICAL LABORATORY, 2022, 68 (02) : 367 - 373
  • [6] Point-of-care prothrombin time testing in paediatric intensive care: an observational study of the ease of use of two devices
    Urwyler, Natalie
    Staub, Eveline
    Staub, Lukas P.
    Daetwyler, Karin
    Fluri, Simon
    Sollberger, Tanja
    Theiler, Lorenz
    Greif, Robert
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (02) : 75 - 81
  • [7] Prothrombin time and activated partial thromboplastin time using a point-of-care analyser (Abaxis VSpro®) in Bennett's wallabies (Macropus rufogriseus)
    Nevitt, B. N.
    Chinnadurai, S. K.
    Watson, M. K.
    Langan, J. N.
    Adkesson, M. J.
    AUSTRALIAN VETERINARY JOURNAL, 2016, 94 (10) : 384 - 386
  • [8] Comparison of prothrombin time values of standard laboratory test and two point-of-care devices
    Urwyler, N.
    Staub, E.
    Staub, L.
    Daetwyler, K.
    Fluri, S.
    Sollberger, T.
    Deplaces, M.
    Theiler, L.
    Greif, R.
    SWISS MEDICAL WEEKLY, 2008, 138 (41-42) : 5S - 5S
  • [9] Prothrombin time and activated partial thromboplastin time reference intervals in dogs, by gender and age group using the Start®4 (Stago)
    Barbosa, Marta
    Pires, Maria Joao
    Queiroga, Felisbina
    Pires, Carlos Andre
    Dinis, Tania
    Silvestre-Ferreira, Ana C.
    CIENCIA RURAL, 2022, 52 (10):
  • [10] Standardization of Coagulation Factor V Reference Intervals, Prothrombin Time, and Activated Partial Thromboplastin Time in Mice for Use in Factor V Deficiency Pathological Models
    De Pablo-Moreno, Juan A.
    Liras, Antonio
    Revuelta, Luis
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9