Clinical outcomes of single full-coverage lithium disilicate restorations: A systematic review

被引:2
作者
Al-Dulaijan, Yousif A. [1 ]
Aljubran, Hussain M. [2 ]
Alrayes, Nabras M. [2 ]
Aldulaijan, Hajer A. [3 ]
AlSharief, Mishali [4 ]
Aljofi, Faisal E. [4 ]
Ibrahim, Maria S. [4 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Substitut Dent Sci, POB 1982, Dammam 31441, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Dent, POB 1982, Dammam 31441, Saudi Arabia
[3] King Saud Univ, Coll Dent, Dept Periodont & Community Dent, Riyadh, Saudi Arabia
[4] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Prevent Dent Sci, POB 1982, Dammam 31441, Saudi Arabia
基金
英国科研创新办公室;
关键词
All-ceramic; Full-coverage crowns; Periodontal change; Post-operative sensitivity; Pulpal involvement; Recurrent caries; ALL-CERAMIC CROWNS; FIXED DENTAL PROSTHESES; MARGINAL FIT; CAD/CAM; SURVIVAL; ZIRCONIA; CHAIRSIDE; COMPLICATIONS; SENSITIVITY; PERFORMANCE;
D O I
10.1016/j.sdentj.2023.05.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Lithium disilicate glass-ceramic (LDC) restorations exhibit microorgan-ism infiltration, recurrent caries, pulpal lesions, periodontal inflammation, and cement exposure to the oral environment over time. All these factors lead to restoration failure. This systematic review aimed to investigate the clinical outcomes of LDC full-coverage crowns (FCC) in permanent teeth compared with those of other full-coverage restoration materials. Materials & Methods: Search strategies were developed for four databases: Web of Science, OVID, PubMed, and Scopus. Data extraction and quality appraisals were performed by two inde-pendent reviewers. Data on the presence of caries, post-operative sensitivity, and periodontal changes were extracted from the included clinical studies. In addition to the outcome measures, data on the sample size, study groups, method of restoration fabrication, type of impression, and type of abutment were recorded. Results: We retrieved 3989 records for the title and abstract screening. Of these, 19 clinical stud-ies met the inclusion criteria. The overall quality of the included studies indicates a low risk of bias. Most studies reported no pulpal involvement, recurrent caries, or post-operative sensitivity and presented a favorable periodontal response after the cementation of LDC-FCC during different follow-up periods. Conclusion: Based on the endodontic and periodontic clinical responses of natural tooth abutments and their supporting periodontium, LDC-FCC can be considered a clinically successful restorative option. & COPY; 2023 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:403 / 422
页数:20
相关论文
共 71 条
[1]  
Ahmed K. E., 2018, PRIM DENT J, V7, P30, DOI DOI 10.1177/205016841800700205
[2]   Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD-CAM systems [J].
Ahn, Jong-Ju ;
Bae, Eun-Bin ;
Lee, Jin-Ju ;
Choi, Jae-Won ;
Jeon, Young-Chan ;
Jeong, Chang-Mo ;
Yun, Mi-Jung ;
Lee, So-Hyoun ;
Lee, Kyu-Bok ;
Huh, Jung-Bo .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02) :239-247
[3]   Acid Effects on the Physical Properties of Different CAD/CAM Ceramic Materials: An in Vitro Analysis [J].
Al-Thobity, Ahmad M. ;
Gad, Mohammed M. ;
Farooq, Imran ;
Alshahrani, Abdullah S. ;
Al-Dulaijan, Yousif A. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (02) :135-141
[4]   3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions [J].
Anadioti, Evanthia ;
Aquilino, Steven A. ;
Gratton, David G. ;
Holloway, Julie A. ;
Denry, Isabelle ;
Thomas, Geb W. ;
Qian, Fang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08) :610-617
[5]   Use of molecular indicators of inflammation to assess the biocompatibility of all-ceramic restorations [J].
Ariaans, Kirsten ;
Heussen, Nicole ;
Schiffer, Hanna ;
Wienert, Anna-Lena ;
Pluemaekers, Birgit ;
Rink, Lothar ;
Wolfart, Stefan .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2016, 43 (02) :173-179
[6]   Clinical performance of chairside monolithic lithium disilicate glass-ceramic CAD-CAM crowns [J].
Aziz, Ahmed ;
El-Mowafy, Omar ;
Tenenbaum, Howard C. ;
Lawrence, Herenia P. ;
Shokati, Babak .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (06) :613-619
[7]   CLINICAL OUTCOMES OF THREE DIFFERENT CROWN SYSTEMS WITH CAD/CAM TECHNOLOGY [J].
Batson, Emily R. ;
Cooper, Lyndon F. ;
Duqum, Ibrahim ;
Mendonca, Gustavo .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (04) :770-777
[8]   Postoperative tooth sensitivity with a new self-adhesive resin cement-a randomized clinical trial [J].
Blatz, Markus B. ;
Mante, Francis K. ;
Saleh, Najeed ;
Atlas, Alan M. ;
Mannan, Sahurabh ;
Ozer, Fusun .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (03) :793-798
[9]   The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems [J].
Brawek, Petya K. ;
Wolfart, Stefan ;
Endres, Lutz ;
Kirsten, Armin ;
Reich, Sven .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) :2119-2125
[10]   PLAQUE RETENTION ON TEETH RESTORED WITH FULL-CERAMIC CROWNS - A COMPARATIVE-STUDY [J].
CHAN, C ;
WEBER, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (06) :666-671