Application of green-synthesized carbon dots for imaging of cancerous cell lines and detection of anthraquinone drugs using silica-coated CdTe quantum dots-based ratiometric fluorescence sensor

被引:12
|
作者
Mohammadinejad, Arash [1 ,2 ,3 ]
Abnous, Khalil [2 ]
Nameghi, Morteza Alinezhad [2 ]
Yahyazadeh, Roghayeh [3 ]
Hamrah, Sara [3 ]
Senobari, Fereshteh [3 ]
Mohajeri, Seyed Ahmad [2 ,3 ,4 ]
机构
[1] Mashhad Univ Med Sci, Sch Med, Dept Med Biotechnol & Nanotechnol, Mashhad, Iran
[2] Mashhad Univ Med Sci, Pharmaceut Technol Inst, Pharmaceut Res Ctr, Mashhad, Iran
[3] Mashhad Univ Med Sci, Sch Pharm, Dept Pharmacodynam & Toxicol, Mashhad, Iran
[4] Mashhad Univ Med Sci, Sch Pharm, Mashhad, Iran
关键词
Carbon dots; CdTe quantum dots; Daunorubicin; Doxorubicin; Ratiometric method; Imaging; SELECTIVE DETECTION; ANTICANCER DRUGS; ONE-STEP; DOXORUBICIN; DAUNORUBICIN; PROBES; NANOPARTICLES; MITOXANTRONE; DEGRADATION; ELECTRODE;
D O I
10.1016/j.saa.2022.122200
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Chemotherapy drugs of daunorubicin and doxorubicin treat cancers with many side effects. So, detection of them in the biological system for regulation and controlling of usage is essential. In this study, a ratiometric fluorescent method was introduced for detection of daunorubicin and doxorubicin using bell pepper-based carbon dots, as the variable signal, and silica-coated CdTe quantum dots, as the constant signal. The detection was done based on variations of carbon dots intensity in the presence of drugs in comparison with the constant intensity of silica-coated CdTe quantum dots. The proposed ratiometric fluorescent method was successfully used for detection of daunorubicin and doxorubicin range of 54.37-13594.34 nmolL-1 and 86.2-17242 nmolL-1, with a detection limit of 18.53 nmolL-1 and 29 nmolL-1, respectively. Also, this method was used for detection of drugs in serum samples with recovery ranges of 86.14-99.62 (RSD 3-1.47%) and 86.32-97.53 (3.38-1.48%), respectively. Finally, after evaluation of carbon dots toxicity by MTT test, carbon dots was applied for imaging of prostate cancer cell lines (PC3) and breast cancer cell lines (MCF7). The results demonstrated that despite improvement of the repeatability and interferences reduction by ratiometric method, also carbon dots were successfully applied for imaging of cell lines.
引用
收藏
页数:10
相关论文
共 3 条
  • [1] Research Progress on Detection Mechanism and Application of Carbon Dots-based Ratiometric Fluorescence Sensor
    Li Q.-Z.
    Zhou Y.-H.
    Chen Y.
    Lu F.
    Qian J.
    Cao S.
    Faguang Xuebao/Chinese Journal of Luminescence, 2020, 41 (05): : 579 - 591
  • [2] Ratiometric fluorescence nanosensor for selective and visual detection of cadmium ions using quencher displacement-induced fluorescence recovery of CdTe quantum dots-based hybrid probe
    Qian, Jing
    Wang, Kan
    Wang, Chengquan
    Ren, Chanchan
    Liu, Qian
    Hao, Nan
    Wang, Kun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 1153 - 1160
  • [3] Turn-off fluorescence sensor for the detection of ferric ion in water using green synthesized N-doped carbon dots and its bio-imaging
    Edison, Thomas Nesakumar Jebakumar Immanuel
    Atchudan, Raji
    Shim, Jae-Jin
    Kalimuthu, Senthilkumar
    Ahn, Byeong-Cheol
    Lee, Yong Rok
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2016, 158 : 235 - 242