摘要
Introduction The aim of this study is to describe and evaluate double Preserflo MicroShunt implantation as a modified micro-invasive glaucoma surgery technique and to retrospectively compare the outcomes in a cohort of glaucoma patients with single or double implantation.Materials and Methods A retrospective data analysis of 57 glaucoma patients who consecutively underwent Preserflo implantation was performed. Medical records were examined for patients' demographics, glaucoma type, intraocular pressure (IOP), medication, complications and re-interventions. Two groups with single (n=29) or double (n=28) implantation were formed and the outcomes were compared. In cases of two-stage double implantation (n=17), the course of the initial and the second implantation were compared.ResultsMean preoperative IOP was significantly higher in the double compared to the single implantation group (29.4 +/- 10.0mmHg; 21.7 +/- 8.2mmHg; P=0.003). Postoperatively, IOP was significantly lower in the double implantation group at various time-points (day 1, week 1, months 3 and 6; all P<0.021). In the subgroup with two-stage procedures, mean preoperative IOP was 24.5 +/- 8.5mmHg and 29.8 +/- 10.1mmHg, respectively; P=0.128). While immediately postoperatively, mean IOP-lowering was clinically significant and similar following both procedures, thelonger sustainable effect was observed after the second procedure (month 12: 25.5 +/- 7.5mmHg; 12.4 +/- 4.8mmHg; P=0.001). No serious complications were observedDiscussion/Conclusion Double Preserflo implantation appears safe and efficient for lowering IOP in glaucoma patients. Our preliminary findings suggest that double is superior to single implantation in terms of IOP-lowering and the need for additional topical medication. Patients with insufficient IOP-lowering following single implantation may benefit from a second implantation. Further research is warranted to evaluate double implantation as a first-line, one-stage procedure.
引用
收藏
页码:1362 / 1375
页数:14
相关论文
共 50 条
[21]   Preserflo MicroShunt Implantation for Glaucoma Secondary to Viral and Juvenile Idiopathic Arthritis-Related Anterior Uveitis [J].
Nasyrov, Emil ;
Seppelfricke, Clara ;
Doycheva, Deshka ;
Gassel, Caroline J. ;
Merle, David A. ;
Voykov, Bogomil .
OCULAR IMMUNOLOGY AND INFLAMMATION, 2024,
[22]   Systematic Preserflo MicroShunt Intraluminal Stenting for Hypotony Prevention in Highly Myopic Patients: A Comparative Study [J].
Lupardi, Enrico ;
Laffi, Gian Luca ;
Moramarco, Antonio ;
Barboni, Piero ;
Fontana, Luigi .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (04)
[23]   Efficacy and Safety of PreserFlo® MicroShunt After a Failed Trabeculectomy in Eyes with Primary Open-Angle Glaucoma: A Retrospective Study [J].
Luciano Quaranta ;
Eleonora Micheletti ;
Roberto Carassa ;
Carlo Bruttini ;
Riccardo Fausto ;
Andreas Katsanos ;
Ivano Riva .
Advances in Therapy, 2021, 38 :4403-4412
[24]   Surgical success 2 years after preserflo microshunt implantation: real world data from a single eye care centre [J].
Hinterberger, Sarah ;
Schneider, Sophie ;
Kallab, Martin ;
Murauer, Olivia ;
Reisinger, Anna-Sophie ;
Bolz, Matthias ;
Strohmaier, Clemens A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
[25]   MicroShunt versus Trabeculectomy for Surgical Management of Glaucoma: A Retrospective Analysis [J].
Fu, Michael X. ;
Normando, Eduardo M. ;
Luk, Sheila M. H. ;
Deshmukh, Mira ;
Ahmed, Faisal ;
Crawley, Laura ;
Ameen, Sally ;
Vig, Niten ;
Cordeiro, Maria Francesca ;
Bloom, Philip A. .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (18)
[26]   PreserFlo™ MicroShunt Versus Trabeculectomy in Patients With Moderate to Advanced Open-Angele Glaucoma: 12-Month Follow-up of a Single-Center Prospective Study [J].
Fili, Sofia ;
Kontopoulou, Kalliopi ;
Vastardis, Iraklis ;
Perdikakis, Georgios ;
Kohlhaas, Markus .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
[27]   Long-term Results of the PRESERFLO MicroShunt in Patients With Primary Open-angle Glaucoma From a Single-center Nonrandomized Study [J].
Batlle, Juan F. ;
Corona, Adalgisa ;
Albuquerque, Rachel .
JOURNAL OF GLAUCOMA, 2021, 30 (03) :281-286
[28]   Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma [J].
Ahmed, Iqbal Ike K. ;
Sadruddin, Omar ;
Panarelli, Joseph F. .
EYE AND VISION, 2023, 10 (01)
[29]   Risk Factors for Failure in Glaucoma Patients Undergoing Microshunt Implantation [J].
Rabiolo, Alessandro ;
Toscani, Rebecca ;
Sacchi, Matteo ;
Destefanis, Pietro ;
Bettin, Paolo ;
Ciampi, Carlo ;
Clemente, Antonella ;
Cutolo, Carlo alberto ;
Mercieca, Karl ;
Iester, Michele ;
Traverso, Carlo enrico ;
Di Maita, Marco ;
Li Calzi, Gaia ;
Nucci, Paolo ;
Bandello, Francesco ;
Triolo, Giacinto ;
De Cilla, Stefano .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 259 :117-130
[30]   Subconjunctival filtration in evolution: current evidence on MicroShunt implantation for treating patients with glaucoma [J].
Iqbal Ike K. Ahmed ;
Omar Sadruddin ;
Joseph F. Panarelli .
Eye and Vision, 10