Effects of Section Compactness and SCWB Condition on Moment Redistribution and Plastic Hinging in SMF Built-Up Box Columns

被引:6
|
作者
Chou, Chung-Che [1 ,2 ]
Xiong, Hou-Chun [1 ]
Kumar, Agam [1 ]
Lai, Yun-Chuan [1 ]
Uang, Chia-Ming [3 ]
机构
[1] Natl Taiwan Univ, Dept Civil Engn, Taipei 106319, Taiwan
[2] Natl Ctr Res Earthquake Engn, Taipei, Taiwan
[3] Univ Calif La Jolla, Dept Struct Engn, La Jolla, CA 92093 USA
关键词
Built-up box column; Two-story subassemblage; Boundary condition; Width-thickness ratio; Strong column-weak beam (SCWB) ratio; SHAPE-MEMORY ALLOYS; SEISMIC PERFORMANCE; RESISTING FRAMES; BRACED FRAMES; STEEL FRAME; BEHAVIOR; CONNECTIONS; CONCRETE; SYSTEMS; DESIGN;
D O I
10.1061/JSENDH.STENG-12273
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel special moment frames (SMFs) with built-up box columns and I-shaped beams commonly are used for seismic design, especially in Asian countries. Modern seismic design codes assume that plastic hinging will occur near the base of columns and in the reduced beam section (RBS) region; a strong column-weak beam (SCWB) check is required to reduce the likelihood that column hinging will occur above the first story. This study investigated the effects of column section compactness (i.e., width-thickness ratio), axial force level, and SCWB ratio on the moment redistribution and plastic hinging in the bottom two stories of the columns. Two half-scale, two-and-one-half-story subassemblages with a column and RBS beams were cyclically tested; steel beams were included to simulate a realistic boundary condition to the column, especially after the beams started to form plastic hinges. The experimental observations of two subassemblages with varying column width-thickness ratios and SCWB ratios showed that meeting the SCWB requirement does not necessarily preclude plastic hinging in the second-story column. A finite-element parametric study with nine subassemblage models was conducted. A design criterion with an expression containing both the width-thickness and SCWB ratios is proposed to achieve plastic hinging near the column base, but not elsewhere along the columns.
引用
收藏
页数:16
相关论文
共 5 条
  • [1] Mechanics of cold-formed steel built-up box section columns in local buckling modes
    Li, Yanchun
    Li, Ruibo
    Zhou, Tianhua
    Han, Aihong
    Li, Weihua
    STRUCTURES, 2025, 71
  • [2] Seismic performance of pre-northridge welded steel moment connections to built-up box columns
    Kim, Taejin
    Stojadinovic, Bozidar
    Whittaker, Andrew S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (02) : 289 - 299
  • [3] Compressive behavior of built-up closed box section columns consisting of two cold-formed steel channels
    Nie, Shao-Feng
    Zhou, Tian-Hua
    Zhang, Yang
    Liu, Bo
    THIN-WALLED STRUCTURES, 2020, 151
  • [4] Experimental investigation of lightweight aggregate concrete-filled cold-formed built-up box section (CFBBS) stub columns under axial compression
    Bin Teoh, Keat
    Chua, Yie Sue
    Pang, Sze Dai
    Kong, Sih Ying
    ENGINEERING STRUCTURES, 2023, 279
  • [5] Ultimate load-carrying capacity of cold-formed thin-walled columns with built-up box and I section under axial compression
    Li, Yuanqi
    Li, Yinglei
    Wang, Shukun
    Shen, Zuyan
    THIN-WALLED STRUCTURES, 2014, 79 : 202 - 217