Cyclic Behavior of Beam-Column Pocket Connections in GFRP-Reinforced Precast Concrete Assemblages

被引:10
作者
Ghanbari-Ghazijahani, Tohid [1 ]
Hassanli, Reza [2 ]
Manalo, Allan [3 ]
Smith, Scott T. [4 ]
Vincent, Tom [5 ]
Gravina, Rebecca [6 ]
Zhuge, Yan [7 ]
机构
[1] Macquarie Univ, Sydney, Australia
[2] Univ South Australia, UniSA STEM, Mawson Lakes, SA 5095, Australia
[3] Univ Southern Queensland, Fac Hlth Engn & Sci, Ctr Future Mat, Darling Hts, Qld 4350, Australia
[4] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
[5] Flinders Univ S Australia, Coll Sci & Engn, Bedford Pk, SA 5042, Australia
[6] Univ Queensland, Sch Civil Engn, St Lucia, Qld 4072, Australia
[7] Univ South Australia, UniSA STEM, Mawson Lakes, SA 5095, Australia
关键词
Beam-column connection; Precast concrete; GFRP reinforcement; Cyclic loading; Pocket connection; SEISMIC BEHAVIOR;
D O I
10.1061/JCCOF2.CCENG-3863
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents details of an experimental program evaluating the behavior of six half-scale glass fiber-reinforced polymer (GFRP) reinforced concrete beam-column precast members connected together through pocket connections, which are subjected to cyclic loading. The novel beam-column connection was constructed by incorporating either epoxy resin or tensioned or untensioned GFRP rock bolts in conjunction with different-sized pocket connections. The effects of an additional connection bar between the column and beam components in the connection, as well as the confinement of the concrete around the pocket region, were also investigated. An innovative test setup was designed so that the beam-column joint could rotate without restraint provided by the supports. All specimens were tested under an incrementally increasing cyclic load. The load-carrying capacity, deformational behavior, failure modes, energy dissipation, and hysteretic damping were all recorded and evaluated. All specimens failed as a result of column failure within the pocket connection region. This was attributed to the relative rotational flexibility of the column with respect to the beam, owing to the low elasticity of the epoxy resin used in the pocket region, and hence the stress concentration at the column ends within the pocket area. According to the results, a pocket connection containing GFRP reinforcement providing confinement around the embedded area yielded the highest capacity, ductility, and energy dissipation under cyclic loading. The connection containing a GFRP bolt, regardless of whether or not the bolt was prestressed, did not significantly improve the performance of the connection. The findings presented here can be used for the design of precast elements reinforced with GFRP bars. Of particular relevance is application to jetties and other offshore concrete infrastructure where steel reinforcement (because of corrosion issues) needs to be replaced with GFRP reinforcement.
引用
收藏
页数:17
相关论文
共 30 条
[1]  
ACI (American Concrete Institute), 2002, 352 ACI ACIASCE
[2]  
ACI (American Concrete Institute), 2001, ACC CRIT MOM FRAM BA
[3]  
[Anonymous], 1999, STANDARD TEST METHOD, DOI DOI 10.1520/D1586-11
[4]  
[Anonymous], 1996, Seismic evaluation and retrofit of concrete buildings
[5]   Effects of Diameter on the Durability of Glass Fiber-Reinforced Polymer Bars Conditioned in Alkaline Solution [J].
Benmokrane, Brahim ;
Manalo, Allan ;
Bouhet, Jean-Charles ;
Mohamed, Khaled ;
Robert, Mathieu .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (05)
[6]  
Canbolat BB, 2008, ACI STRUCT J, V105, P154
[7]   Development and testing of precast concrete beam-to-column connections [J].
Choi, H. -K. ;
Choi, Y. -C. ;
Choi, C. -S. .
ENGINEERING STRUCTURES, 2013, 56 :1820-1835
[8]   Effect of Shear Studs and High Moments on Punching Behavior of GFRP-RC Slab-Column Edge Connections [J].
El-Gendy, M. G. ;
El-Salakawy, Ehab .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (04)
[9]  
El-Gendy M. G., 2018, SPEC PUBL J L B SMIT, V322, p5.1
[10]   GFRP Shear Reinforcement for Slab-Column Edge Connections Subjected to Reversed Cyclic Lateral Load [J].
El-Gendy, Mohammed G. ;
El-Salakawy, Ehab F. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2020, 24 (02)