Improvement of imaging and image correction methods for the soft X-ray projection microscopy

被引:0
作者
Jigmeddorj, Vanchinkhuu [1 ]
Jamsranjav, Erdenetogtokh [2 ]
Baatar, Duurenbuyan [1 ,2 ]
Kinjo, Yasuhito [3 ]
Ito, Atsushi [4 ]
Shiina, Tatsuo [5 ]
机构
[1] Natl Univ Mongolia, Sch Arts & Sci, Dept Phys, Ikh Surguuliin Gudamj 1, Ulaanbaatar 14201, Mongolia
[2] Mongolian Acad Sci, Inst Phys & Technol, Lab Radiat Biophys, Ulaanbaatar, Mongolia
[3] High Energy Accelerator Res Org, Inst Mat Struct Sci, Ibaraki, Japan
[4] Tokai Univ, Sch Engn, Kawasaki, Kanagawa, Japan
[5] Chiba Univ, Grad Sch Engn, Chiba, Japan
关键词
Soft X-ray projection microscopy; imaging; Pt-blue; image correction; iteration procedure; contrast enhancement; chromosome; grayscale value; PHASE RETRIEVAL; RECONSTRUCTION; CONTRAST; CELLS;
D O I
10.3233/XST-230056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: The soft X-ray projection microscope has been developed for high resolution imaging of hydrated biospecimens. Image blurring due to X-ray diffraction can be corrected by an iteration procedure. The correction is not efficient enough for all images, especially for low contrast chromosome images. OBJECTIVE: The purpose of this study is to improve X-ray imaging techniques using a finer pinhole and reducing capture time, as well as to improve image correction methods. A method of specimen staining prior to the imaging was tested in order to capture images with high contrasts. The efficiency of the iteration procedure and its combined version with an image enhancement method was also assessed. METHODS: In image correction, we used the iteration procedure and its combined version with an image enhancement technique. To capture higher contrast images, we stained chromosome specimens with the Platinum blue (Pt-blue) prior to the imaging. RESULTS: The iteration procedure combined with image enhancement corrected the chromosome images with 329 or lower magnification effectively. Using the Pt-blue staining for the chromosome, images with high contrast have been captured and successfully corrected. CONCLUSIONS: The image enhancement technique combining contrast enhancement and noise removal together was effective to obtain higher contrast images. As a result, the chromosome images with 329 or lower times magnification were corrected effectively. With Pt-blue staining, chromosome images with contrasts of 2.5 times higher than unstained case could be captured and corrected by the iteration procedure.
引用
收藏
页码:951 / 964
页数:14
相关论文
共 34 条
  • [11] Jamsranjav Erdenetogtokh, 2017, Radioisotopes, V66, P137, DOI 10.3769/radioisotopes.66.137
  • [12] Evaluation of noise limits to improve image processing in soft X-ray projection microscopy
    Jamsranjav, Erdenetogtokh
    Kuge, Kenichi
    Ito, Atsushi
    Kinjo, Yasuhito
    Shiina, Tatsuo
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (04) : 653 - 665
  • [13] Effect of Contrast Enhancement Prior to Iteration Procedure on Image Correction for Soft X-ray Projection Microscopy
    Jamsranjav, Erdenetogtokh
    Shiina, Tatsuo
    Kuge, Kenichi
    Kinjo, Yasuhito
    Nakamura, Yuichi
    Shinohara, Kunio
    Ito, Atsushi
    [J]. XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696
  • [14] SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS
    KIRZ, J
    JACOBSEN, C
    HOWELLS, M
    [J]. QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) : 33 - 130
  • [16] X-ray microscopy
    Lider, V. V.
    [J]. PHYSICS-USPEKHI, 2017, 60 (02) : 187 - 203
  • [17] Liehr Thomas, 2002, P73
  • [18] Majima T, 2004, TRAC-TREND ANAL CHEM, V23, P520, DOI [10.1016/S0165-9936(04)00735-6, 10.1016/s0165-9936(04)00735-6]
  • [19] X-ray image reconstruction from a diffraction pattern alone
    Marchesini, S
    He, H
    Chapman, HN
    Hau-Riege, SP
    Noy, A
    Howells, MR
    Weierstall, U
    Spence, JCH
    [J]. PHYSICAL REVIEW B, 2003, 68 (14):
  • [20] Quantitative X-ray projection microscopy: phase-contrast and multi-spectral imaging
    Mayo, SC
    Miller, PR
    Wilkins, SW
    Davis, TJ
    Gao, D
    Gureyev, TE
    Paganin, D
    Parry, DJ
    Pogany, A
    Stevenson, AW
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 2002, 207 : 79 - 96