A prospective comparison of invasive and non-invasive blood pressure in children undergoing cardiac catheterization

被引:3
作者
Beringer, Richard [1 ,4 ]
Keith, Alastair [1 ]
Jones, Elin [2 ]
Murphy, Tim [1 ]
White, Paul [3 ]
机构
[1] Bristol Royal Hosp Children, Bristol, England
[2] Birmingham Childrens Hosp, Birmingham, England
[3] Univ West England, Bristol, England
[4] Bristol Royal Hosp Children, Upper Maudlin St, Bristol BS2 8BJ, England
关键词
blood pressure; blood pressure determination; cardiac catheterization; child; hypotension; HEART-DISEASE; ACCURACY; INFANTS;
D O I
10.1111/pan.14723
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Blood pressure measurement is a standard of monitoring during general anesthesia. Invasive measurement is considered the gold standard but is less commonly used than non-invasive. Automated oscillometric blood pressure devices measure the mean arterial pressure (MAP) and use an algorithm to determine the systolic and diastolic pressures. Few devices have been validated in children, particularly during anesthesia. Few studies have assessed the agreement between invasive and non-invasive blood pressure measurements in children. Methods: This was a multi-center prospective observational study of children under 16 years undergoing cardiac catheterization with general anesthesia. Paired invasive and non-invasive blood pressure measurements were recorded for each patient during stable periods of the procedure. Correlation within and between sites was assessed with Pearson's correlation coefficient, and agreement was examined using Bland-Altman methodology to determine bias. Agreement during episodes of hypotension and for age and weight was also determined. Bias greater than 5 mmHg and standard deviation greater than 8 mmHg was considered clinically significant. The primary end point was agreement of MAP measurements. Results: A total of 683 paired blood pressure values were collected from 254 children in three pediatric hospitals. Median [IQR] age and weight were 3 [1-7] years and 13.9 [8-23] Kg. The overall bias (SD) for mean arterial pressure values was 7.2 (11.4) mmHg. During hypotension (190 readings), the bias (SD) was 15 (11.0) mmHg. The non-invasive MAP was frequently higher than invasive MAP during infancy, and lower in older children. Conclusion: Automated oscillometric blood pressure measurement is unreliable in anesthetized children during cardiac catheterization. Invasive pressure measurement should be considered for high-risk cases.
引用
收藏
页码:816 / 822
页数:7
相关论文
共 18 条
[1]   Blood Pressure Monitoring for the Anesthesiologist: A Practical Review [J].
Bartels, Karsten ;
Esper, Stephen A. ;
Thiele, Robert H. .
ANESTHESIA AND ANALGESIA, 2016, 122 (06) :1866-1879
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Correlation between invasive and noninvasive blood pressure measurements in severely burned children [J].
Cambiaso-Daniel, Janos ;
Rontoyanni, Victoria G. ;
Foncerrada, Guillermo ;
Nguyen, Anthony ;
Capek, Karel D. ;
Wurzer, Paul ;
Lee, Jong O. ;
Hundeshagen, Gabriel ;
Voigt, Charles D. ;
Branski, Ludwik K. ;
Finnerty, Celeste C. ;
Herndon, David N. .
BURNS, 2018, 44 (07) :1787-1791
[4]   Pulse Wave Analysis What Do the Numbers Mean? [J].
Chowienczyk, Phil .
HYPERTENSION, 2011, 57 (06) :1051-1052
[5]   Reference Values for Noninvasive Blood Pressure in Children during Anesthesia A Multicentered Retrospective Observational Cohort Study [J].
de Graaff, Jurgen C. ;
Pasma, Wietze ;
Buuren, Stef van ;
Duijghuisen, Jesse J. ;
Nafiu, Olubukola O. ;
Kheterpal, Sachin ;
van Klei, Wilton A. .
ANESTHESIOLOGY, 2016, 125 (05) :904-913
[6]   Method of Blood Pressure Measurement in Neonates and Infants: A Systematic Review and Analysis [J].
Dionne, Janis M. ;
Bremner, Stephen A. ;
Baygani, Simin K. ;
Batton, Beau ;
Ergenekon, Ebru ;
Bhatt-Mehta, Varsha ;
Dempsey, Eugene ;
Kluckow, Martin ;
Koplowitz, Luana Pesco ;
Apele-Freimane, Dina ;
Iwami, Hiroko ;
Klein, Agnes ;
Turner, Mark ;
Rabe, Heike .
JOURNAL OF PEDIATRICS, 2020, 221 :23-+
[7]   Comparing oscillometric noninvasive and invasive intra-arterial blood pressure monitoring in term neonates under general anesthesia: A retrospective study [J].
Fujii, Tasuku ;
Nishiwaki, Kimitoshi .
PEDIATRIC ANESTHESIA, 2020, 30 (12) :1396-1401
[8]  
ISO 81060-2:2018(en), 8106022018EN ISO
[9]   Blood pressure and flow in pediatric anesthesia: An educational review [J].
Karlsson, Jacob ;
Lonnqvist, Per-Arne .
PEDIATRIC ANESTHESIA, 2022, 32 (01) :10-16
[10]   Perioperative Noninvasive Blood Pressure Monitoring [J].
Kuck, Kai ;
Baker, Philip D. .
ANESTHESIA AND ANALGESIA, 2018, 127 (02) :408-411