EFFICACY AND SAFETY OF NONFLUOROSCOPIC APPROACH DURING CATHETER ABLATION OF VENTRICULAR TACHYCARDIAS

被引:1
作者
Huseynli, E. G. [1 ]
Sapelnikov, O. V. [1 ]
Amanatova, V. A. [1 ]
Ardus, D. F. [1 ]
Khachirov, M. R. [1 ]
Grishin, I. R. [1 ]
Cherkashin, D. I. [1 ]
Saidova, M. A. [1 ]
Stukalova, O. V. [1 ]
Shlevkov, N. B. [1 ]
Uskach, T. M. [1 ]
Akchurin, R. S. [1 ]
机构
[1] Chazov Natl Med Res Ctr Cardiol, Moscow, Russia
关键词
Ventricular tachycardia; radiofrequency catheter ablation; nonfluoroscopic approach; intracardiac echocardiography; RADIATION-EXPOSURE; MEDICAL STAFF;
D O I
10.18087/cardio.2023.3.n2243
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To evaluate a possibility of using radiofrequency catheter ablation guided by intracardiac echo-cardiography (ICE), its efficacy and safety for treatment of ventricular tachycardia (VT) of various etiology.Material and Methods Catheter intervention was performed for 20 enrolled patients with symptomatic VT. Ablation procedures were guided by a 3D electroanatomical mapping system and ICE.Results Mean duration of the procedure was 201.2 +/- 62.5 min. The procedure was successful (non-inducibility of VT) in 100% of cases. None of the patients had postoperative complications.Conclusion Ablation of VT arrhythmogenic substrate guided by 3D electroanatomical navigational mapping and ICE without X-ray is feasible and safe.
引用
收藏
页码:36 / 45
页数:83
相关论文
共 19 条
[1]   The occupational effects of interventional cardiology: results from the WIN for Safety survey [J].
Buchanan, Gill Louise ;
Chieffo, Alaide ;
Mehilli, Julinda ;
Mikhail, Ghada W. ;
Mauri, Fina ;
Presbitero, Patrizia ;
Grinfeld, Liliana ;
Petronio, Anna Sonia ;
Skelding, Kimberly A. ;
Hoye, Angela ;
Mehran, Roxana ;
Morice, Marie-Claude .
EUROINTERVENTION, 2012, 8 (06) :658-663
[2]   Catheter Ablation of Atrial Fibrillation Using Zero-Fluoroscopy Technique: A Randomized Trial [J].
Bulava, Alan ;
Hanis, Jiri ;
Eisenberger, Martin .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (07) :797-806
[3]  
Cronin EM, 2019, EUROPACE, V21, P1143, DOI 10.1093/europace/euz132
[4]   Exclusion of Fluoroscopy Use in Catheter Ablation Procedures: Six Years of Experience at a Single Center [J].
Fernandez-Gomez, Juan M. ;
Morina-Vazquez, Pablo ;
Del Rio Morales, Elena ;
Venegas-Gamero, Jose ;
Barba-Pichardo, Rafael ;
Herrera Carranza, Manuel .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (06) :638-644
[5]   Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study [J].
Haeusler, Uwe ;
Czarwinski, Renate ;
Brix, Gunnar .
EUROPEAN RADIOLOGY, 2009, 19 (08) :2000-2008
[6]   ALARA AND AN INTEGRATED APPROACH TO RADIATION PROTECTION [J].
HENDEE, WR ;
EDWARDS, FM .
SEMINARS IN NUCLEAR MEDICINE, 1986, 16 (02) :142-150
[7]   Zero fluoroscopy approach versus fluoroscopy approach for cardiac arrhythmia ablations: A systematic review and meta-analysis [J].
Kanitsoraphan, Chanavuth ;
Techorueangwiwat, Chol ;
Rattanawong, Pattara ;
Kewcharoen, Jakrin ;
Ayinapudi, Karnika ;
Bunch, T. Jared ;
Groh, Christopher ;
Navaravong, Leenhapong .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (10) :2761-2776
[8]   Operator learning curve and clinical outcomes of zero fluoroscopy catheter ablation of atrial fibrillation, supraventricular tachycardia, and ventricular arrhythmias [J].
Kochar, Arshneel ;
Ahmed, Taha ;
Donnellan, Eoin ;
Wazni, Oussama ;
Tchou, Patrick ;
Chung, Roy .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 61 (01) :165-170
[9]  
[Костин В.С. Kostin V.S.], 2021, [Кардиологический вестник, Russian Cardiology Bulletin, Kardiologicheskii vestnik], V16, P49, DOI 10.17116/Cardiobulletin20211604149
[10]   RADIATION EXPOSURE FOR MEDICAL STAFF PERFORMING QUANTITATIVE CORONARY PERFUSION PET WITH 13N-AMMONIA [J].
Kristoffersen, Ulrik Sloth ;
Gutte, Henrik ;
Skovgaard, Dorthe ;
Andersen, Peter Andreas ;
Kjaer, Andreas .