Reproducibility of cerebral perfusion measurements using BOLD delay

被引:2
|
作者
Khalil, Ahmed A. [1 ,2 ,3 ,4 ,8 ]
Tanritanir, Ayse C. [1 ]
Grittner, Ulrike [4 ,5 ]
Kirilina, Evgeniya [6 ,7 ]
Villringer, Arno [2 ,3 ]
Fiebach, Jochen B. [1 ]
Mekle, Ralf [1 ]
机构
[1] Charite Univ Med Berlin, Ctr Stroke Res Berlin, Berlin, Germany
[2] Humboldt Univ, Berlin Sch Mind & Brain, Berlin, Germany
[3] Max Planck Inst Human Cognit & Brain Sci, Dept Neurol, Leipzig, Germany
[4] Berlin Inst Hlth BIH, Berlin, Germany
[5] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, Berlin, Germany
[6] Max Planck Inst Human Cognit & Brain Sci, Dept Neurophys, Leipzig, Germany
[7] Free Univ, Ctr Cognit Neurosci Berlin, Berlin, Germany
[8] Charite Campus Benjamin Franklin, Ctr Stroke Res Berlin, Hindenburgdamm 30, D-12200 Berlin, Germany
关键词
blood flow; BOLD delay; perfusion; reproducibility; resting-state functional MRI; TEST-RETEST RELIABILITY; FUNCTIONAL CONNECTIVITY MRI; HEAD MOTION; CIRCULATION TIME; FMRI SIGNAL; STROKE; LONG;
D O I
10.1002/hbm.26244
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
BOLD delay is an emerging, noninvasive method for assessing cerebral perfusion that does not require the use of intravenous contrast agents and is thus particularly suited for longitudinal monitoring. In this study, we assess the reproducibility of BOLD delay using data from 136 subjects with normal cerebral perfusion scanned on two separate occasions with scanners, sequence parameters, and intervals between scans varying between subjects. The effects of various factors on the reproducibility of BOLD delay, defined here as the differences in BOLD delay values between the scanning sessions, were investigated using a linear mixed model. Reproducibility was additionally assessed using the intraclass correlation coefficient of BOLD delay between sessions. Reproducibility was highest in the posterior cerebral artery territory. The mean BOLD delay test-retest difference after accounting for the aforementioned factors was 1.2 s (95% CI = 1.0 to 1.4 s). Overall, BOLD delay shows good reproducibility, but care should be taken when interpreting longitudinal BOLD delay changes that are either very small or are located in certain brain regions.
引用
收藏
页码:2778 / 2789
页数:12
相关论文
共 50 条
  • [31] Quantitative assessment of the reproducibility of functional activation measured with BOLD and MR perfusion imaging: Implications for clinical trial design
    Tjandra, T
    Brooks, JCW
    Figueiredo, P
    Wise, R
    Matthews, PM
    Tracey, I
    NEUROIMAGE, 2005, 27 (02) : 393 - 401
  • [32] Perfusion measurements of the brain:: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke
    Klotz, E
    König, M
    EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) : 170 - 184
  • [33] Cerebral perfusion measurements using continuous arterial spin labeling: accuracy and limits of a quantitative approach
    Kimura, H
    Kabasawa, H
    Yonekura, Y
    Itoh, H
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 238 - 247
  • [34] Measurements of cerebral perfusion and arterial hemodynamics during visual stimulation using Turbo-TILT
    Hendrikse, J
    Lu, HZ
    van der Grond, J
    van Zijl, PCM
    Golay, X
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) : 429 - 433
  • [35] REPRODUCIBILITY OF CEREBRAL GLUCOSE METABOLIC MEASUREMENTS IN RESTING HUMAN-SUBJECTS
    BARTLETT, EJ
    BRODIE, JD
    WOLF, AP
    CHRISTMAN, DR
    LASKA, E
    MEISSNER, M
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04): : 502 - 512
  • [36] Prehospital <bold>delay </bold>and mortality in stroke patients
    Garcia Ruiz, R.
    Silva Fernandez, J.
    Garcia Ruiz, R. M.
    Recio Bermejo, M.
    Santos Pinto, A.
    Lomas Meneses, A.
    Millan Pascual, J.
    Turpin Fenoll, L.
    Vadillo Bermejo, A.
    Enrique, B. P.
    CEREBROVASCULAR DISEASES, 2018, 45 : 369 - 369
  • [37] Reproducibility of glucose measurements using the glucose sensor
    Metzger, M
    Leibowitz, G
    Wainstein, J
    Glaser, B
    Raz, I
    DIABETES CARE, 2002, 25 (07) : 1185 - 1191
  • [38] Reproducibility of glucose measurements using the glucose sensor
    Armstrong, D
    King, A
    DIABETES, 2003, 52 : A89 - A89
  • [39] Reproducibility of wavefront measurements using the LADARWave aberrometer
    Lewis, Craig D.
    Krueger, Ronald R.
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : S973 - S979
  • [40] Effects of Acquisition Parameter Modifications and Field Strength on the Reproducibility of Brain Perfusion Measurements Using Arterial Spin-Labeling
    Baas, K. P. A.
    Petr, J.
    Kuijer, J. P. A.
    Nederveen, A. J.
    Mutsaerts, H. J. M. M.
    van de Ven, K. C. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (01) : 109 - 115