Reproducibility of cerebral perfusion measurements using BOLD delay

被引:2
|
作者
Khalil, Ahmed A. [1 ,2 ,3 ,4 ,8 ]
Tanritanir, Ayse C. [1 ]
Grittner, Ulrike [4 ,5 ]
Kirilina, Evgeniya [6 ,7 ]
Villringer, Arno [2 ,3 ]
Fiebach, Jochen B. [1 ]
Mekle, Ralf [1 ]
机构
[1] Charite Univ Med Berlin, Ctr Stroke Res Berlin, Berlin, Germany
[2] Humboldt Univ, Berlin Sch Mind & Brain, Berlin, Germany
[3] Max Planck Inst Human Cognit & Brain Sci, Dept Neurol, Leipzig, Germany
[4] Berlin Inst Hlth BIH, Berlin, Germany
[5] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, Berlin, Germany
[6] Max Planck Inst Human Cognit & Brain Sci, Dept Neurophys, Leipzig, Germany
[7] Free Univ, Ctr Cognit Neurosci Berlin, Berlin, Germany
[8] Charite Campus Benjamin Franklin, Ctr Stroke Res Berlin, Hindenburgdamm 30, D-12200 Berlin, Germany
关键词
blood flow; BOLD delay; perfusion; reproducibility; resting-state functional MRI; TEST-RETEST RELIABILITY; FUNCTIONAL CONNECTIVITY MRI; HEAD MOTION; CIRCULATION TIME; FMRI SIGNAL; STROKE; LONG;
D O I
10.1002/hbm.26244
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
BOLD delay is an emerging, noninvasive method for assessing cerebral perfusion that does not require the use of intravenous contrast agents and is thus particularly suited for longitudinal monitoring. In this study, we assess the reproducibility of BOLD delay using data from 136 subjects with normal cerebral perfusion scanned on two separate occasions with scanners, sequence parameters, and intervals between scans varying between subjects. The effects of various factors on the reproducibility of BOLD delay, defined here as the differences in BOLD delay values between the scanning sessions, were investigated using a linear mixed model. Reproducibility was additionally assessed using the intraclass correlation coefficient of BOLD delay between sessions. Reproducibility was highest in the posterior cerebral artery territory. The mean BOLD delay test-retest difference after accounting for the aforementioned factors was 1.2 s (95% CI = 1.0 to 1.4 s). Overall, BOLD delay shows good reproducibility, but care should be taken when interpreting longitudinal BOLD delay changes that are either very small or are located in certain brain regions.
引用
收藏
页码:2778 / 2789
页数:12
相关论文
共 50 条
  • [21] Test-retest reproducibility of quantitative CBF measurements using FAIR perfusion MRI and acetazolamide challenge
    Yen, YF
    Field, AS
    Martin, EM
    Ari, N
    Burdette, JH
    Moody, DM
    Takahashi, AM
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 921 - 928
  • [22] Reproducibility of semi-automated hepatic perfusion measurements using 15O-water PET
    Lubberink, M.
    Runesson, P.
    Lindstrom, E.
    Roslin, S.
    Vessby, J.
    Antoni, G.
    Rorsman, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S297 - S297
  • [23] Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
    Spilt, A
    Box, FMA
    van der Geest, RJ
    Reiber, JHC
    Kunz, P
    Kamper, AM
    Blauw, GJ
    van Buchem, MA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (01) : 1 - 5
  • [24] Cerebral CT Perfusion Using an Interventional C-Arm Imaging System: Cerebral Blood Flow Measurements
    Ganguly, A.
    Fieselmann, A.
    Marks, M.
    Rosenberg, J.
    Boese, J.
    Deuerling-Zheng, Y.
    Straka, M.
    Zaharchuk, G.
    Bammer, R.
    Fahrig, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (08) : 1525 - 1531
  • [25] ORR Measurements Reproducibility Using a RRDE
    Garsany, Yannick
    Ge, Junjie
    St-Pierre, Jean
    Rocheleau, Richard
    Swider-Lyons, Karen E.
    POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 1233 - 1241
  • [26] Reproducibility of the brain perfusion index for measuring cerebral blood flow using technetium-99m compounds
    Murase, K
    Fujioka, H
    Inoue, T
    Ishimaru, Y
    Akamune, A
    Yamamoto, Y
    Mochizuki, T
    Ikezoe, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (11) : 1640 - 1646
  • [27] Mapping cerebral perfusion in mice under various anesthesia levels using highly sensitive BOLD MRI with transient hypoxia
    Le, Thuy Thi
    Im, Geun Ho
    Lee, Chan Hee
    Choi, Sang Han
    Kim, Seong-Gi
    SCIENCE ADVANCES, 2024, 10 (09)
  • [28] The reproducibility of the calibrated BOLD in health and disease
    Ances, B.
    Vaida, F.
    Buxton, R.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S572 - S572
  • [29] Non-invasive monitoring of longitudinal changes in cerebral hemodynamics in acute ischemic stroke using BOLD signal delay
    Khalil, Ahmed A.
    Villringer, Kersten
    Filleboeck, Vivien
    Hu, Jiun-Yiing
    Rocco, Andrea
    Fiebach, Jochen B.
    Villringer, Arno
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2020, 40 (01): : 23 - 34
  • [30] Reproducibility of absolute myocardial perfusion measurements with rubidium-82 PET imaging
    Beauchesne, LM
    Ruddy, TD
    deKemp, RA
    Aung, MT
    Levesque, N
    Alvarez-Diaz, T
    Vickers, TK
    Aubrey, BA
    Beanlands, RSB
    CIRCULATION, 1998, 98 (17) : 222 - 222