Reproducibility of cerebral perfusion measurements using BOLD delay

被引:2
|
作者
Khalil, Ahmed A. [1 ,2 ,3 ,4 ,8 ]
Tanritanir, Ayse C. [1 ]
Grittner, Ulrike [4 ,5 ]
Kirilina, Evgeniya [6 ,7 ]
Villringer, Arno [2 ,3 ]
Fiebach, Jochen B. [1 ]
Mekle, Ralf [1 ]
机构
[1] Charite Univ Med Berlin, Ctr Stroke Res Berlin, Berlin, Germany
[2] Humboldt Univ, Berlin Sch Mind & Brain, Berlin, Germany
[3] Max Planck Inst Human Cognit & Brain Sci, Dept Neurol, Leipzig, Germany
[4] Berlin Inst Hlth BIH, Berlin, Germany
[5] Charite Univ Med Berlin, Inst Biometry & Clin Epidemiol, Berlin, Germany
[6] Max Planck Inst Human Cognit & Brain Sci, Dept Neurophys, Leipzig, Germany
[7] Free Univ, Ctr Cognit Neurosci Berlin, Berlin, Germany
[8] Charite Campus Benjamin Franklin, Ctr Stroke Res Berlin, Hindenburgdamm 30, D-12200 Berlin, Germany
关键词
blood flow; BOLD delay; perfusion; reproducibility; resting-state functional MRI; TEST-RETEST RELIABILITY; FUNCTIONAL CONNECTIVITY MRI; HEAD MOTION; CIRCULATION TIME; FMRI SIGNAL; STROKE; LONG;
D O I
10.1002/hbm.26244
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
BOLD delay is an emerging, noninvasive method for assessing cerebral perfusion that does not require the use of intravenous contrast agents and is thus particularly suited for longitudinal monitoring. In this study, we assess the reproducibility of BOLD delay using data from 136 subjects with normal cerebral perfusion scanned on two separate occasions with scanners, sequence parameters, and intervals between scans varying between subjects. The effects of various factors on the reproducibility of BOLD delay, defined here as the differences in BOLD delay values between the scanning sessions, were investigated using a linear mixed model. Reproducibility was additionally assessed using the intraclass correlation coefficient of BOLD delay between sessions. Reproducibility was highest in the posterior cerebral artery territory. The mean BOLD delay test-retest difference after accounting for the aforementioned factors was 1.2 s (95% CI = 1.0 to 1.4 s). Overall, BOLD delay shows good reproducibility, but care should be taken when interpreting longitudinal BOLD delay changes that are either very small or are located in certain brain regions.
引用
收藏
页码:2778 / 2789
页数:12
相关论文
共 50 条
  • [1] Reproducibility of BOLD, perfusion, and CMRO2 measurements with calibrated-BOLD fMRI
    Leontiev, Oleg
    Buxton, Richard B.
    NEUROIMAGE, 2007, 35 (01) : 175 - 184
  • [2] Reproducibility of cerebral vasoreactivity measurements using FAIR perfusion MR and acetazolamide challenge
    Field, AS
    Yen, Y
    Martin, EM
    Burdette, JH
    Takahashi, AM
    Hernandez, L
    RADIOLOGY, 2000, 217 : 555 - 555
  • [3] Normal cerebral perfusion measurements using arterial spin labeling: Reproducibility, stability, and age and gender effects
    Parkes, LM
    Rashid, W
    Chard, DT
    Tofts, PS
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 736 - 743
  • [4] Resolution and reproducibility of BOLD and perfusion functional MRI at 3.0 tesla
    van Gelderen, P
    Wu, CWH
    de Zwart, JA
    Cohen, L
    Hallett, M
    Duyn, JH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 569 - 576
  • [5] Reproducibility of measurements of cerebral infarct volume
    van der Worp, HB
    Claus, SS
    Baer, PRD
    Ramos, LMP
    Algra, A
    van Gijn, J
    Kappelle, LJ
    STROKE, 2000, 31 (01) : 335 - 335
  • [6] Reproducibility of hypocapnic cerebrovascular reactivity measurements using BOLD fMRI in combination with a paced deep breathing task
    Sousa, I.
    Vilela, P.
    Figueiredo, P.
    NEUROIMAGE, 2014, 98 : 31 - 41
  • [7] REPRODUCIBILITY OF CEREBRAL-ARTERY DOPPLER MEASUREMENTS
    MOORTHY, B
    COLDITZ, PR
    IVES, KN
    REES, DG
    VANTHOFF, WG
    HOPE, PL
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1990, 65 (07): : 700 - 701
  • [8] Reproducibility of Tumor Perfusion Measurements Using 15O-Labeled Water and PET
    de Langen, Adrianus J.
    Lubberink, Mark
    Boellaard, Ronald
    Spreeuwenberg, Marieke D.
    Smit, Egbert F.
    Hoekstra, Otto S.
    Lammertsma, Adriaan A.
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) : 1763 - 1768
  • [9] Cerebral Perfusion Measurements in Elderly with Hypertension Using Arterial Spin Labeling
    Mutsaerts, H. J. M. M.
    van Dalen, J. W.
    Heijtel, D. F. R.
    Groot, P. F. C.
    Majoie, C. B. L. M.
    Petersen, E. T.
    Richard, E.
    Nederveen, A. J.
    PLOS ONE, 2015, 10 (08):
  • [10] Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiography
    Chen, Chieh-Li
    Bojikian, Karine D.
    Xin, Chen
    Wen, Joanne C.
    Gupta, Divakar
    Zhang, Qinqin
    Mudumbai, Raghu C.
    Johnstone, Murray A.
    Chen, Philip P.
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)