Validation of microwave-assisted digestion and Inductive coupled plasma -mass spectrometer for the determination of trace metals in the soil around Darvill sludgeland and their environmental complications

被引:4
作者
Dlamini, Hlengiwe [1 ]
Mahlambi, Precious [1 ]
Mngadi, Sihle [2 ]
机构
[1] Univ KwaZulu, Dept Chem & Phys, Pietermaritzburg Campus,King Edward Ave, Pietermaritzburg, South Africa
[2] Chem Sci Umgeni Water, Sci Serv Labs, Pietermaritzburg, South Africa
来源
SOIL & SEDIMENT CONTAMINATION | 2023年 / 32卷 / 06期
关键词
Trace metals; environmental implication; method validation; geo-accumulation index; HEAVY-METALS; RISK-ASSESSMENT; LEAD; CHROMIUM; MOBILITY; CADMIUM; ACID; CONTAMINATION; ACCUMULATION; REMEDIATION;
D O I
10.1080/15320383.2022.2123446
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents the optimization, validation, and application of microwave-assisted digestion and inductively coupled plasma mass spectrometry (ICP-MS) for the simultaneous determination of trace metals (B, Cd, Co, Cr, Cu, Mo, Ni, Pb, Se, V, Zn, and As) in soils from sludgeland. This analytical method was validated according to the requirements of ISO standards for new methods, which include parameters such as linearity, sensitivity and range, accuracy, precision, selectivity, the limit of detection (LOD), the limit of quantification (LOQ), and recoveries. The method demonstrated good linearity with a correlation coefficient greater than 0.999 for all 12 metals of interest. The limit of detection (LOD) was found to be between 0.001 and 0.006 mu g/L and the Limit of Quantification (LOQ) was between 5 and 200 mu g/L. The method was then applied to soil samples from 28 sites where sludge is disposed to assess the presence of trace metals and their concentrations were compared with background concentrations of metals in South Africa. The Cr with the value ranging from 83.5 mg/kg to 480 mg/kg exceeded the limits in all sites while Zn, Co, Ni, As exceeded in some sites. Geo accumulation was then used to categorize the contamination level of soil by trace metals and observed to be strongly contaminated by Zn with values between 1.2 and 3.5 while moderately contaminated by Pb, Ni, Cu, and As with values between 1.3 and 2.7 which poses their environmental risk.
引用
收藏
页码:637 / 651
页数:15
相关论文
共 27 条
  • [21] Determination of trace elements of Melicope patulinervia from different part by microwave digestion-inductively coupled plasma-mass spectrometry (ICP-MS)
    Guo, Ying
    Liu, Hua-liang
    Yuan, Ke
    JOURNAL OF MEDICINAL PLANTS RESEARCH, 2011, 5 (19): : 4925 - 4930
  • [22] Validation of the Analytical Procedure for Quantitative Determination of Four Trace Metals (As, Cd, Pb, and Hg) in Fish Lipids Using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)
    Jayakody, Kasun S.
    Edirisinghe, Ranjith K. B.
    Senevirathne, Suchithra A.
    Senarathna, Lalith
    MASS SPECTROMETRY LETTERS, 2024, 15 (03) : 149 - 157
  • [23] A method for rapid determination of arsenic species in vegetables using microwave-assisted extraction followed by detection with HPLC hyphenated to inductively coupled plasma-mass spectrometry
    Jia, Xintong
    Yang, Xiaoyue
    Zhao, Wei
    Hu, Yuanan
    Cheng, Hefa
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (18) : 2957 - 2967
  • [24] Inductively Coupled Plasma Collision Cell Quadrupole Mass Spectrometric Determination of Extractible Arsenic, Cadmium, Chromium, Lead, Mercury, and Other Elements in Food Using Microwave-Assisted Digestion: Results from an FDA Interlaboratory Study
    Gray, Patrick J.
    Cunningham, William
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (02) : 590 - 604
  • [25] Determination of seven arsenic species in seafood by ion exchange chromatography coupled to inductively coupled plasma-mass spectrometry following microwave assisted extraction: Method validation and occurrence data
    Leufroy, Axelle
    Noel, Laurent
    Dufailly, Vincent
    Beauchemin, Diane
    Guerin, Thierry
    TALANTA, 2011, 83 (03) : 770 - 779
  • [26] Graphene oxide-silica composite coating hollow fiber solid phase microextraction online coupled with inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental water samples
    Su, Shaowei
    Chen, Beibei
    He, Man
    Hu, Bin
    TALANTA, 2014, 123 : 1 - 9