Numerical modelling of a single-compression multi-temperature ejector-supported R744 refrigeration unit for last mile delivery

被引:3
作者
Fabris, Francesco [1 ]
Bodys, Jakub [2 ]
Marinetti, Sergio [1 ]
Minetto, Silvia [1 ]
Lka, Jacek Smo [2 ]
Rossetti, Antonio [1 ]
机构
[1] CNR, Construct Technol Inst CNR ITC, I-35127 Padua, Italy
[2] Silesian Univ Tech, Inst Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
关键词
Refrigeration; Carbon Dioxide; Refrigerated transport; Multi-temperature transport; Ejector; CARBON-DIOXIDE; HEAT-TRANSFER; PERFORMANCE;
D O I
10.1016/j.ijrefrig.2024.01.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel R744 vapor -compression refrigeration system has been developed to meet the cooling needs of a medium -size refrigerated truck at two temperature levels: 4-5 kW for medium -temperature (MT) refrigeration at 0 degrees C and 1-2 kW for low -temperature (LT) refrigeration at -20 degrees C. This system is designed for transporting chilled and frozen goods efficiently during last -mile deliveries in urban areas. The key innovation of this system lies in its single compression stage with two different evaporation levels. Firstly, the unit incorporates an MT ejector to enhance energy efficiency by reducing the compressor pressure ratio. Furthermore, an LT ejector is employed to allow providing LT cooling with a single -stage compressor by pre -compressing vapor before it enters the compressor, avoiding excessive compression ratios. This extends the LT operational range with a single stage of compression from 34 degrees C to 40 degrees C ambient temperature. When the ambient temperature is not sufficient to sustain the ejector cycle, the system can switch to a back -pressure cycle. A numerical model of this refrigeration system has been developed to evaluate its steady-state and dynamic performance in both back -pressure and ejector configurations. For a specific cooling effect production (3.8 kW in MT, 1.1 kW in LT operation), the ejector cycle increases the COP by 25.8% for MT and 42.0% for LT operation compared to the back -pressure cycle. However, the back -pressure cycle offers greater flexibility in cooling power production, ranging from -32.8% to +8.2% for MT and -8.9% to +82.5% for LT, making it useful for pulldown and part -load operations.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 35 条
[1]  
Ansible, 2023, ABOUT US
[2]   Modelling the performance of a new cooling unit for refrigerated transport using carbon dioxide as the refrigerant [J].
Artuso, Paolo ;
Marinetti, Sergio ;
Minetto, Silvia ;
Del Col, Davide ;
Rossetti, Antonio .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 :158-171
[3]   Integrated CO2 systems for supermarkets: Field measurements and assessment for alternative solutions in hot climate [J].
Azzolin, Marco ;
Cattelan, Gianluca ;
Dugaria, Simone ;
Minetto, Silvia ;
Calabrese, Livio ;
Del Col, Davide .
APPLIED THERMAL ENGINEERING, 2021, 187
[4]   Performance evolution on a dual-temperature CO2 transcritical refrigeration cycle with two cascade ejectors [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
APPLIED THERMAL ENGINEERING, 2017, 120 :26-35
[5]  
Banasiak K, 2019, CONGRES INT FROID, P3327, DOI 10.18462/iir.icr.2019.0307
[6]   Full-scale multi-ejector module: for a carbon dioxide supermarket refrigeration system: Numerical study of performance evaluation [J].
Bodys, Jakub ;
Palacz, Michal ;
Haida, Michal ;
Smolka, Jacek ;
Nowak, Andrzej J. ;
Banasiak, Krzysztof ;
Hafner, Armin .
ENERGY CONVERSION AND MANAGEMENT, 2017, 138 :312-326
[7]   STUDY OF EUROPEAN F-GAS REGULATION IMPACT ON REFRIGERATED TRANSPORT EQUIPMENT [J].
Cavalier, Gerald ;
Valet, Olivier ;
Hardy, Matthieu ;
Bourez, Delphine ;
Fertel, Camille .
26TH IIR INTERNATIONAL CONGRESS OF REFRIGERATION, VOL 3, 2023, :784-791
[8]  
CHURCHILL SW, 1977, CHEM ENG-NEW YORK, V84, P91
[9]  
Dorin, 2022, CD Series. Semi-hermetic motor compressors. Transcritical CO2 application - 50/60 Hz
[10]   Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation [J].
Elbel, Stefan ;
Hrnjak, Pega .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03) :411-422