A New Potentiometric Sensor Based on Carbon Paste Electrode Modified with Methacrylic Acid Based-Ion Imprinted Polymer for Nickel Ion Determination

被引:1
作者
Alizadeh, Taher [1 ]
Rashedi, Maryam [1 ]
Ghadiri, Amir Mohammad [1 ]
机构
[1] Univ Tehran, Univ Coll Sci, Fac Chem, Dept Analyt Chem, POB 14155-6455, Tehran, Iran
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2023年 / 15卷 / 10期
关键词
Carbon paste; Ion imprinted polymer; Potentiometry; Nickel ion; Methacrylic acid; ADSORPTIVE STRIPPING VOLTAMMETRY; ELECTROCHEMICAL SENSING PLATFORM; PVC MEMBRANE-ELECTRODE; SELECTIVE DETERMINATION; SAMPLES; PRECONCENTRATION; PERFORMANCE; CARRIER; MWCNTS; LEAD;
D O I
10.22034/abec.2023.708675
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel ion-imprinted polymer (IIP)-based potentiometric sensor is introduced for precise determination of Ni2+ ions. The imprinted polymer was prepared using methacrylic acid and ethylene glycol dimethacrylate as functional monomer and cross-linker. This potentiometric sensor is a carbon paste electrode, composed of IIP particles (4%), graphite (64%), n-eicosane (25%), and sodium tetra phenyl borate (5%) in its optimum condition. The sensor exhibited a Nernstian slope of 29.1 +/- 0.4 mVdecade-1 in the concentration range of 1.0x10-6 to 1.0x10-1 mol L-1 with a detection limit of 5x10-7mol L-1. The sensor demonstrated a stable potential response in the pH range of 4-7 and fast response times below 1 minute. Thanks to the high selectivity of the IIP-based probe, common interfering species had almost no effect on its response toward Ni2+ ions. The proposed sensor was prosperously applied to analyze the Ni2+ content of real sea, lake, and industrial water samples.
引用
收藏
页码:860 / 873
页数:14
相关论文
共 51 条
[1]   Simultaneous determination of iron and nickel as contaminants in multimineral and multivitamin supplements by solid sampling HR-CS GF AAS [J].
Adolfo, Franciele Rovasi ;
do Nascimento, Paulo Cicero ;
Leal, Gabriela Camera ;
Bohrer, Denise ;
Viana, Carine ;
de Carvalho, Leandro Machado ;
Colim, Alexsandro Nunes .
TALANTA, 2019, 195 :745-751
[2]   Highly selective and sensitive iodide sensor based on carbon paste electrode modified with nanosized sulfate-doped α-Fe2O3 [J].
Alizadeh, Taher ;
Zargr, Fatemeh .
MATERIALS CHEMISTRY AND PHYSICS, 2020, 240
[3]   All-solid-state Cr(III)-selective potentiometric sensor based on Cr(III)-imprinted polymer nanomaterial/MWCNTs/carbon nanocomposite electrode [J].
Alizadeh, Taher ;
Mirzaee, Sahar ;
Rafiei, Faride .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (13) :1283-1297
[4]   Determination of subnanomolar levels of mercury (II) by using a graphite paste electrode modified with MWCNTs and Hg(II) -imprinted polymer nanoparticles [J].
Alizadeh, Taher ;
Hamidi, Negin ;
Ganjali, Mohamad Reza ;
Rafiei, Faride .
MICROCHIMICA ACTA, 2018, 185 (01)
[5]   A new electrochemical sensing platform for Cr(III) determination based on nano-structured Cr(III)-imprinted polymer-modified carbon composite electrode [J].
Alizadeh, Taher ;
Rafiei, Faride ;
Hamidi, Negin ;
Ganjali, Mohamad Reza .
ELECTROCHIMICA ACTA, 2017, 247 :812-819
[6]   Improvement of durability and analytical characteristics of arsenic-imprinted polymer-based PVC membrane electrode via surface modification of nano-sized imprinted polymer particles: part 2 [J].
Alizadeh, Taher ;
Rashedi, Mariyam ;
Hanifehpour, Younes ;
Joo, Sang Woo .
ELECTROCHIMICA ACTA, 2015, 178 :877-885
[7]   A carbon paste electrode impregnated with Cd2+ imprinted polymer as a new and high selective electrochemical sensor for determination of ultra-trace Cd2+ in water samples [J].
Alizadeh, Taher ;
Ganjali, Mohamad Reza ;
Nourozi, Parviz ;
Zare, Mashaalah ;
Hoseini, Mahmoud .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 657 (1-2) :98-106
[8]   Preparation of nano-sized Pb2+ imprinted polymer and its application as the chemical interface of an electrochemical sensor for toxic lead determination in different real samples [J].
Alizadeh, Taher ;
Amjadi, Somaye .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 190 (1-3) :451-459
[9]  
Allowances R.D., 1989, Recommended dietary allowances
[10]   A tetra-co ordinate nickel(II) complex as neutral carrier for nitrate-selective PVC membrane electrode [J].
Asghari, AR ;
Amini, MK ;
Mansour, HR ;
Salavati-Niasari, M .
TALANTA, 2003, 61 (04) :557-563