Comparison of Three Video Laryngoscopes and Direct Laryngoscopy for Emergency Endotracheal Intubation While Wearing PPE-AGP: A Randomized, Crossover, Simulation Trial

被引:5
作者
Kluj, Przemyslaw [1 ]
Fedorczak, Anna [2 ,3 ]
Fedorczak, Michal [1 ]
Gaszynski, Tomasz [1 ]
Kulak, Cezary [4 ]
Wasilewski, Mikolaj [5 ]
Znyk, Mateusz [4 ]
Bartczak, Maria [4 ]
Ratajczyk, Pawel [1 ]
机构
[1] Med Univ Lodz, Dept Anesthesiol & Intens Care, PL-90549 Lodz, Poland
[2] Med Univ Lodz, Dept Pediat Nephrol & Immunol, PL-93338 Lodz, Poland
[3] Polish Mothers Mem Hosp, Res Inst, Dept Endocrinol & Metab Dis, PL-93338 Lodz, Poland
[4] Med Univ Lodz, Med Simulat Ctr, PL-92213 Lodz, Poland
[5] Med Univ Lodz, Clin Anesthesiol & Intens Therapy, PL-92213 Lodz, Poland
关键词
endotracheal intubation; paramedic; direct laryngoscopy; video laryngoscopy; personal protective equipment; HOSPITAL CARDIAC-ARREST; PERSONAL PROTECTIVE EQUIPMENT; AIRWAY MANAGEMENT; TRACHEAL INTUBATION; PHYSICIANS; MACINTOSH; RADIATION; INSERTION; DEVICES;
D O I
10.3390/healthcare11060884
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: The COVID-19 pandemic has necessitated changes in the safety protocols of endotracheal intubation at every level of care. This study aimed to compare the first-pass success rates (FPS) and intubation times (IT) of three video laryngoscopes (VL) and direct laryngoscopy (DL) for simulated COVID-19 patient emergency intubation (EI). Methods: The study was a prospective, randomized, crossover trial. Fifty-three active paramedics performed endotracheal intubation with the I-view(TM) VL, UESCOPE(R) VL, ProVu(R) VL and Macintosh direct laryngoscope (MAC) wearing personal protective equipment for aerosol-generating procedures (PPE-AGP) on a manikin with normal airway conditions. Results: The longest IT was noted when the UESCOPE(R) (29.4 s) and ProVu(R) (27.7 s) VL were used. The median IT for I-view was 17.4 s and for MAC DL 17.9 s. The FPS rates were 88.6%, 81.1%, 83.0% and 84.9%, respectively, for I-view, ProVu(R), UESCOPE(R) and MAC DL. The difficulty of EI attempts showed a statistically significant difference between UESCOPE(R) and ProVu(R). Conclusions: The intubation times performed by paramedics in PPE-AGP using UESCOPE(R) and ProVu(R) were significantly longer than those with the I-view and Macintosh laryngoscopes. The use of VL by prehospital providers in PPE did not result in more effective EI than the use of a Macintosh laryngoscope.
引用
收藏
页数:11
相关论文
共 27 条
[1]   Airway management research: a systematic review [J].
Ahmad, I. ;
Onwochei, D. N. ;
Muldoon, S. ;
Keane, O. ;
El-Boghdadly, K. .
ANAESTHESIA, 2019, 74 (02) :225-236
[2]   Effect of airway management strategies during resuscitation from out -of -hospital cardiac arrest on clinical outcome: A registry -based analysis [J].
Behrens, Niels-Henning ;
Fischer, Matthias ;
Krieger, Tobias ;
Monaco, Kathleen ;
Wnent, Jan ;
Seewald, Stephan ;
Grasner, Jan-Thorsten ;
Bernhard, Michael .
RESUSCITATION, 2020, 152 :157-164
[3]   Endotracheal intubation versus supraglottic airway placement in out-of-hospital cardiac arrest: A meta-analysis [J].
Benoit, Justin L. ;
Gerecht, Ryan B. ;
Steuerwald, Michael T. ;
McMullan, Jason T. .
RESUSCITATION, 2015, 93 :20-26
[4]   Insertion of six different supraglottic airway devices whilst wearing chemical, biological, radiation, nuclear-personal protective equipment: a manikin study [J].
Castle, N. ;
Pillay, Y. ;
Spencer, N. .
ANAESTHESIA, 2011, 66 (11) :983-988
[5]   Risks to healthcare workers following tracheal intubation of patients with COVID-19: a prospective international multicentre cohort study [J].
El-Boghdadly, K. ;
Wong, D. J. N. ;
Owen, R. ;
Neuman, M. D. ;
Pocock, S. ;
Carlisle, J. B. ;
Johnstone, C. ;
Andruszkiewicz, P. ;
Baker, P. A. ;
Biccard, B. M. ;
Bryson, G. L. ;
Chan, M. T. V. ;
Cheng, M. H. ;
Chin, K. J. ;
Coburn, M. ;
Fagerlund, M. Jonsson ;
Myatra, S. N. ;
Myles, P. S. ;
O'Sullivan, E. ;
Pasin, L. ;
Shamim, F. ;
van Klei, W. A. ;
Ahmad, I. .
ANAESTHESIA, 2020, 75 (11) :1437-1447
[6]   Can experienced paramedics perform tracheal intubation at cardiac arrests? Five years experience of a regional air ambulance service in the UK [J].
Fullerton, James N. ;
Roberts, Keith J. ;
Wyse, Matthew .
RESUSCITATION, 2009, 80 (12) :1342-1345
[7]   Direct vs. Video-Laryngoscopy for Intubation by Paramedics of Simulated COVID-19 Patients under Cardiopulmonary Resuscitation: A Randomized Crossover Trial [J].
Gadek, Leszek ;
Szarpak, Lukasz ;
Konge, Lars ;
Dabrowski, Marek ;
Telecka-Gadek, Dominika ;
Maslanka, Maciej ;
Drela, Wiktoria Laura ;
Jachowicz, Marta ;
Iskrzycki, Lukasz ;
Bialka, Szymon ;
Peacock, Frank William ;
Smereka, Jacek .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
[8]   Time to intubation with McGrath ™ videolaryngoscope versus direct laryngoscope in powered air-purifying respirator: a randomised controlled trial [J].
Goh, Qing ;
Lie, Sui ;
Tan, Zihui ;
Tan, Pei ;
Ng, Shin ;
Abdullah, Hairil .
SINGAPORE MEDICAL JOURNAL, 2024, 65 (01) :2-8
[9]   Endotracheal Intubation Using C-MAC Video Laryngoscope vs. Direct Laryngoscope While Wearing Personal Protective Equipment [J].
Kim, Da Saem ;
Jeong, Daun ;
Park, Jong Eun ;
Lee, Gun Tak ;
Shin, Tae Gun ;
Chang, Hansol ;
Kim, Taerim ;
Lee, Se Uk ;
Yoon, Hee ;
Cha, Won Chul ;
Sim, Yong Jin ;
Park, Song Yi ;
Hwang, Sung Yeon .
JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (10)
[10]  
Ludwin K., 2020, DISASTER EMERG MED J, V5, P85, DOI [10.5603/DEMJ.a2020.0023, DOI 10.5603/DEMJ.A2020.0023]