Set-up errors of the neck are underestimated using the overall registration frame of head and neck in IMRT for NPC

被引:2
作者
Xua, Junjie [1 ]
Wang, Tong [1 ]
Luo, Yu [1 ]
Shang, Lintao [1 ]
Mai, Xiuying [1 ]
Ruan, Junjie [1 ]
Pan, Xiaofen [2 ]
Chi, Feng [1 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Oncol South China, Canc Ctr, 651 East Dongfeng Rd, Guangzhou 510060, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 7, Dept Oncol, 628 Zhenyuan Rd, Shenzhen 518100, Peoples R China
关键词
Nasopharyngeal carcinoma; set-up error; registration frame; IMRT; CBCT; IMAGE-GUIDED RADIOTHERAPY; TARGET VOLUMES CTV; UNCERTAINTIES; DELINEATION; CARCINOMA; CANCERS; TUMOR;
D O I
10.3233/XST-230024
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: There is no standardized registration frame of cone beam CT (CBCT) in intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). The overall registration frame that covers the whole head and neck is the most commonly used CBCT registration frame for NPC patients in IMRT. OBJECTIVE: To compare the set-up errors using different registration frames of CBCT for NPC to assess the set-up errors for different region of the commonly used clinical overall registration frame. METHODS: 294 CBCT images of 59 NPC patients were collected. Four registration frames were used for matching. The set-up errors were obtained using an automatic matching algorithm and then compared. The expansion margin from the clinical target volume (CTV) to the planned target volume (PTV) in the four groups was also calculated. RESULTS: The average range of the isocenter translation and rotation errors of four registration frames are 0.89 similar to 2.41mm and 0.49 similar to 1.53 degrees, respectively, which results in a significant difference in the set-up errors (p < 0.05). The set-up errors obtained from the overall frame are smaller than those obtained from the head, upper neck, and lower neck frames. The margin ranges of the overall, head, upper neck, and lower neck frames in three translation directions are 1.49 similar to 2.39 mm, 1.92 similar to 2.45 mm, 1.86 similar to 3.54mm and 3.02 similar to 4.78 mm, respectively. The expansion margins calculated from the overall frame are not enough, especially for the lower neck. CONCLUSION: Set-up errors of the neck are underestimated by the overall registration frame. Thus, it is important to improve the position immobilization of the neck, especially the lower neck. The margin of the target volume of the head and neck region should be expanded separately if circumstances permit.
引用
收藏
页码:1067 / 1077
页数:11
相关论文
共 34 条
  • [1] IMRT versus 2D/3D conformal RT in oropharyngeal cancer: A review of the literature and meta-analysis
    Alterio, Daniela
    Gugliandolo, Simone Giovanni
    Augugliaro, Matteo
    Marvaso, Giulia
    Gandini, Sara
    Bellerba, Federica
    Russell-Edu, Samuel William
    De Simone, Irene
    Cinquini, Michela
    Starzynska, Anna
    Zaffaroni, Mattia
    Bacigalupo, Almalina
    Fanetti, Giuseppe
    Durante, Stefano
    Dicuonzo, Samantha
    Orecchia, Roberto
    Jereczek-Fossa, Barbara Alicja
    [J]. ORAL DISEASES, 2021, 27 (07) : 1644 - 1653
  • [2] Planning target volumes for radiotherapy: How much margin is needed?
    Antolak, JA
    Rosen, II
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05): : 1165 - 1170
  • [3] Adequate margins for random setup uncertainties in head-and-neck IMRT
    Astreinidou, E
    Bel, A
    Raaijmakers, CPJ
    Terhaard, CHJ
    Lagendijk, JJW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 938 - 944
  • [4] Image-guided radiotherapy for head and neck carcinoma
    Beddok, A.
    Blanchard, P.
    [J]. CANCER RADIOTHERAPIE, 2018, 22 (6-7): : 617 - 621
  • [5] Failure Patterns of Recurrence and Metastasis After Intensity-Modulated Radiotherapy in Patients With Nasopharyngeal Carcinoma: Results of a Multicentric Clinical Study
    Chen, Sixia
    Yang, Dong
    Liao, Xueyin
    Lu, Ying
    Yu, Bin
    Xu, Meng
    Bin, Ying
    Zhou, Pingting
    Yang, Zhendong
    Liu, Kang
    Wang, Rensheng
    Zhao, Tingting
    Kang, Min
    [J]. FRONTIERS IN ONCOLOGY, 2022, 11
  • [6] Nasopharyngeal carcinoma
    Chen, Yu-Pei
    Chan, Anthony T. C.
    Quynh-Thu Le
    Blanchard, Pierre
    Sun, Ying
    Ma, Jun
    [J]. LANCET, 2019, 394 (10192) : 64 - 80
  • [7] Chi F.H.Z., 2013, Chinese Journal of Cancer Prevention and Treatment, V20, P2
  • [8] Set-up errors in head and neck cancer patients treated with intensity modulated radiation therapy: Quantitative comparison between three-dimensional cone-beam CT and two-dimensional kilovoltage images
    Ciardo, Delia
    Alterio, Daniela
    Jereczek-Fossa, Barbara Alicja
    Riboldi, Marco
    Zerini, Dario
    Santoro, Luigi
    Preve, Eleonora
    Rondi, Elena
    Comi, Stefania
    Serafini, Flavia
    Laudati, Antonio
    Ansarin, Mohssen
    Preda, Lorenzo
    Baroni, Guido
    Orecchia, Roberto
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1015 - 1021
  • [9] Set-up errors in head and neck cancer treated with IMRT technique assessed by cone-beam computed tomography: a feasible protocol
    Delishaj, Durim
    Ursino, Stefano
    Pasqualetti, Francesco
    Matteucci, Fabrizio
    Cristaudo, Agostino
    Soatti, Carlo Pietro
    Barcellini, Amelia
    Paiar, Fabiola
    [J]. RADIATION ONCOLOGY JOURNAL, 2018, 36 (01): : 54 - 62
  • [10] DAILY IMAGE GUIDANCE WITH CONE-BEAM COMPUTED TOMOGRAPHY FOR HEAD-AND-NECK CANCER INTENSITY-MODULATED RADIOTHERAPY: A PROSPECTIVE STUDY
    Den, Robert B.
    Doemer, Anthony
    Kubicek, Greg
    Bednarz, Greg
    Galvin, James M.
    Keane, William M.
    Xiao, Ying
    Machtay, Mitchell
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1353 - 1359