A Microbiological Assessment of Stethoscopes Used by Clinicians in a Tertiary Hospital in Benin City, Nigeria

被引:0
作者
Ehondor, Ogie Tada [1 ]
Ibadin, Ephraim Ehidiamen [2 ]
机构
[1] Univ Benin Teaching Hosp, Dept Med, Benin, Edo State, Nigeria
[2] Univ Benin Teaching Hosp, Med Lab Serv, Med Microbiol Div, Benin, Nigeria
来源
MALAYSIAN JOURNAL OF MEDICAL SCIENCES | 2023年 / 30卷 / 04期
关键词
stethoscope; clinical infection; contamination; pathogen; BACTERIAL-CONTAMINATION; WORKERS;
D O I
10.21315/mjms2023.30.4.9
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The hospital environment serves as a niche for pathogenic microorganisms, so efforts are constantly being made to identify the potential mode of microbial pathogen transmission causing clinical infections. Objective: The aim of this study was to microbiologically examine the stethoscopes used by clinicians at the University of Benin Teaching Hospital (UBTH) in Benin, Nigeria. Methods: A total of 106 clinicians' stethoscopes were cleaned using cotton-tipped swabs dampened with normal saline. This included both earpieces along with the diaphragm (three samples per stethoscope). The samples were then sent to the Medical Microbiology Laboratory of UBTH and processed immediately as per the standard guidelines. The emergent colonies were subsequently identified, and antimicrobial susceptibility tests were performed. Results: A total of 114 (35.8%) bacterial isolates were recovered, including Staphylococcus aureus (S. aureus) (33.3%), coagulase-negative staphylococci (CoNS) (33.3%), Bacillus spp. (22.8%), Acinetobacter spp. (5.3%), Escherichia coli (E. coli) (1.8%) and Klebsiella spp. (3.5%). Diaphragms had the highest yield of methicillin-resistant S. aureus (MRSA) (46.2%) and CoNS (17.9%). Age (P = 0.0387) and cadre of clinician (P = 0.0043) were risk factors for contamination, whereas clinicians who never cleaned their stethoscopes (P = 0.0044) or cleaned only the earpieces (P = 0.0001) had more contaminated stethoscopes. Conclusion: The contamination rate of stethoscopes used by clinicians in Benin City was 56.6%. There is a need to establish proper stethoscope cleaning practices for all cadres of personnel in clinical practice to minimise health risks to patients and healthcare workers (HCW).
引用
收藏
页码:94 / 101
页数:8
相关论文
共 19 条
  • [1] Association between fluoroquinolone resistance and MRSA genotype in Alexandria, Egypt
    Alseqely, Mustafa
    Newton-Foot, Mae
    Khalil, Amal
    El-Nakeeb, Mostafa
    Whitelaw, Andrew
    Abouelfetouh, Alaa
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] [BARROW G.I.F. COWAN STEEL. COWAN STEEL.], 2003, COWAN STEELS MANUAL, V3rd
  • [3] Association of Macrolide Resistance Genotypes and Synergistic Antibiotic Combinations for Combating Macrolide-Resistant MRSA Recovered from Hospitalized Patients
    Bishr, Amr S.
    Abdelaziz, Salma M.
    Yahia, Ibrahim S.
    Yassien, Mahmoud A.
    Hassouna, Nadia A.
    Aboshanab, Khaled M.
    [J]. BIOLOGY-BASEL, 2021, 10 (07):
  • [4] Bacterial flora of stethoscopes' earpieces and otitis externa
    Brook, I
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1997, 106 (09) : 751 - 752
  • [5] Clinical and Laboratory Standards Institute, 2021, Performance standards for antimicrobial susceptibility testing
  • [6] Stethoscope, "the friendly foe" - A study to evaluate bacterial contamination of stethoscopes and disinfection practices
    Datta, Priya
    Kaur, Mandeep
    Rawat, Sangeeta
    Gupta, Varsha
    Chander, Jagdish
    [J]. JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2018, 12 (10): : 887 - 893
  • [7] de Oliveira AC, 2010, REV ESC ENFERM USP, V44, P1112
  • [8] Gurjeet S., 2013, INT J PHARM BIOL SCI, V3, P186
  • [9] Prevalence of mecA gene among staphylococci from clinical samples of a tertiary hospital in Benin City, Nigeria
    Ibadin, Ephraim Ehidiamen
    Enabulele, Idahosa Onaiwu
    Muinah, Fowora
    [J]. AFRICAN HEALTH SCIENCES, 2017, 17 (04) : 1000 - 1010
  • [10] Kalra S, 2021, INFECT CONT HOSP EP, V42, P740, DOI [10.1017/ice.2021.115, 10.20529/IJME.2021.012]