A Non-Newtonian liquid metal enabled enhanced electrography

被引:9
作者
Timosina, Veronika [1 ]
Cole, Tim [1 ]
Lu, Hongda [2 ]
Shu, Jian [3 ]
Zhou, Xiangbo [3 ]
Zhang, Chengchen [4 ]
Guo, Jinhong [5 ]
Kavehei, Omid [6 ,7 ]
Tang, Shi-Yang [1 ]
机构
[1] Univ Birmingham, Dept Elect Elect & Syst Engn, Birmingham B15 2TT, England
[2] Univ Wollongong, Sch Mech Mat Mechatron & Biomed Engn, Wollongong, Australia
[3] Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, CAS Key Lab Mech Behav & Design Mat, Hefei, Peoples R China
[4] Univ New South Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
[5] Chongqing Med Univ, Coll Lab Med, MOE Key Lab Lab Med Diagnost, 1 Yixueyuan Rd, Chongqing 400016, Peoples R China
[6] Univ Sydney, Fac Engn, Sch Biomed Engn, Sydney, NSW 2006, Australia
[7] Univ Sydney, Nano Inst, Sydney, NSW 2006, Australia
基金
英国工程与自然科学研究理事会; 澳大利亚研究理事会;
关键词
GEL-FREE ELECTRODES; DRY EEG ELECTRODES; IMPEDANCE;
D O I
10.1016/j.bios.2023.115414
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Biopotential signals, like electrocardiography (ECG), electromyography (EMG), and electroencephalography (EEG), can help diagnose cardiological, musculoskeletal and neurological disorders. Dry silver/silver chloride (Ag/AgCl) electrodes are commonly used to obtain these signals. While a conductive hydrogel can be added to Ag/AgCl electrodes to improve the contact and adhesion between the electrode and the skin, dry electrodes are prone to movement. Considering that the conductive hydrogel dries over time, the use of these electrodes often creates an imbalanced skin-electrode impedance and a number of sensing issues in the front-end analogue circuit. This issue can be extended to several other electrode types that are commonly in use, in particular, for applications with a need for long-term wearable monitoring such as ambulatory epilepsy monitoring. Liquid metal alloys, such as eutectic gallium indium (EGaIn), can address key critical requirements around consistency and reliability but present challenges on low viscosity and the risk of leakage. To solve these problems, here, we demonstrate the use of a non-eutectic Ga-In alloy as a shear-thinning non-Newtonian fluid to offer superior performance to commercial hydrogel electrodes, dry electrodes, and conventional liquid metals for electrography measurements. This material has high viscosity when still and can flow like a liquid metal when sheared, preventing leakage while allowing the effective fabrication of electrodes. Moreover, the Ga-In alloy not only has good biocompatibility but also offers an outstanding skin-electrode interface, allowing for the long-term acquisition of high-quality biosignals. The presented Ga-In alloy is a superior alternative to conventional electrode materials for real-world elec-trography or bioimpedance measurement.
引用
收藏
页数:9
相关论文
共 44 条
  • [1] Evaluation of surface EMG-based recognition algorithms for decoding hand movements
    Abbaspour, Sara
    Linden, Maria
    Gholamhosseini, Hamid
    Naber, Autumn
    Ortiz-Catalan, Max
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (01) : 83 - 100
  • [2] Fully Untethered Battery-free Biomonitoring Electronic Tattoo with Wireless Energy Harvesting
    Alberto, Jose
    Leal, Cristina
    Fernandes, Claudio
    Lopes, Pedro A.
    Paisana, Hugo
    de Almeida, Anibal T.
    Tavakoli, Mahmoud
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Albulbul Anas, 2016, Bioengineering-Basel, V3, DOI 10.3390/bioengineering3030020
  • [4] Anderson T.J., 1991, J. Phase Equilib, V12, P64
  • [5] [Anonymous], 2012, Pathophysiology of Heart Disease: A Collaborative Project of Medical Students and Faculty
  • [6] Recoverable Liquid Metal Paste with Reversible Rheological Characteristic for Electronics Printing
    Chang, Hao
    Zhang, Pan
    Guo, Rui
    Cui, Yuntao
    Hou, Yi
    Sun, Ziqiao
    Rao, Wei
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (12) : 14125 - 14135
  • [7] Light-driven liquid metal nanotransformers for biomedical theranostics
    Chechetka, Svetlana A.
    Yu, Yue
    Zhen, Xu
    Pramanik, Manojit
    Pu, Kanyi
    Miyako, Eijiro
    [J]. NATURE COMMUNICATIONS, 2017, 8
  • [8] Electronic Textiles for Wearable Point-of-Care Systems
    Chen, Guorui
    Xiao, Xiao
    Zhao, Xun
    Tat, Trinny
    Bick, Michael
    Chen, Jun
    [J]. CHEMICAL REVIEWS, 2022, 122 (03) : 3259 - 3291
  • [9] Chi Yu Mike, 2010, IEEE Rev Biomed Eng, V3, P106, DOI 10.1109/RBME.2010.2084078
  • [10] Liquid Metal Enabled Biodevices
    Cole, Tim
    Khoshmanesh, Khashayar
    Tang, Shi-Yang
    [J]. ADVANCED INTELLIGENT SYSTEMS, 2021, 3 (07)