Real-time underway measurement of ammonium in coastal and estuarine waters using an automated flow analyzer with hollow fiber membrane contactor

被引:7
|
作者
Li, Peng [1 ]
Li, Songtao [1 ]
Yuan, Dongxing [1 ]
Lin, Kunde [1 ,2 ]
机构
[1] Xiamen Univ, Coll Environm & Ecol, Fujian Prov Key Lab Coast Ecol & Environm Studies, Xiamen 361102, Peoples R China
[2] Xiamen Univ, Coll Environm & Ecol, Xiamen 361102, Peoples R China
关键词
Ammonium; Flow injection analysis; Hollow fiber membrane contactor; Indophenol blue; Shipboard underway measurement; INJECTION-ANALYSIS; INDOPHENOL REACTION; NATURAL-WATERS; TRACE AMMONIUM; JIULONG RIVER; NITROGEN; SEAWATER; ION; MARINE; EUTROPHICATION;
D O I
10.1016/j.scitotenv.2023.163281
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonium (NH4+) is an important parameter for aquatic ecosystems. To date, continuous and underway acquisition of NH4+ in coastal and estuarine waters has been challenged by the strongly varying salinity and complex matrices in these waters. To address these issues, a hollow fiber membrane contactor (HFMC) was constructed and incorporated in flow injection analysis (FIA) to achieve online separation/preconcentration of NH4+ in water. In the FIA-HFMC system, NH4+ in the water sample was converted into NH3 under alkaline conditions in the donor channel. The generated NH3 diffused across the membrane and was absorbed in an acid solution in the acceptor channel. The resultant NH4+ in the acceptor was then quantified based on a modified indophenol blue (IPB) method. Parameters affecting the perfor-mance of the FIA-HFMC-IPB system were evaluated and optimized. Under the optimized conditions, the proposed sys-tem exhibited a limit of detection of 0.11 mu mol L-1, with relative standard deviations of 1.0-1.9 % (n = 7), and a good linear response (R2 = 0.9989) for the calibration in the field with NH4+ standards in the range of 0.40-80 mu mol L-1. The proposed system was applied to a shipboard underway measurement of NH4+ in a two-day cruise in the Jiulong River Estuary-Xiamen Bay, China. A good agreement was observed between measurements from the proposed system and those from manual sampling and laboratory analysis. Both laboratory and field results demonstrated that the sys-tem was free of salinity effect and interference from organic nitrogen compounds. The system also showed excellent stability and reliability during a 16-day observation. This work suggests that the proposed FIA-HFMC-IPB system is ap-plicable for the underway measurement of NH4+ in water, especially for estuarine and coastal waters with varying sa-linity and complex matrices.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Measurement and Real-Time Recognition of Driver Trust in Conditionally Automated Vehicles: Using Multimodal Feature Fusions Network
    Yi, Binlin
    Cao, Haotian
    Song, Xiaolin
    Wang, Jianqiang
    Guo, Wenfeng
    Huang, Zhi
    TRANSPORTATION RESEARCH RECORD, 2023, 2677 (08) : 311 - 330
  • [42] Protocol for real-time measurement of mitochondrial respiration in the mouse ocular posterior pole using a Seahorse XFe24 analyzer
    Parmar, Tanu
    Parmar, Vipul M.
    Malek, Goldis
    STAR PROTOCOLS, 2024, 5 (03):
  • [43] Measuring impact of a quality improvement initiative on glaucoma clinic flow using an automated real-time locating system
    Musser, John A.
    Cho, Juno
    Cohn, Amy
    Niziol, Leslie M.
    Ballouz, Dena
    Burke, David T.
    Newman-Casey, Paula Anne
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [44] REAL-TIME ENUMERATION OF ADHERING MICROORGANISMS IN A PARALLEL PLATE FLOW CELL USING AUTOMATED IMAGE-ANALYSIS
    SJOLLEMA, J
    BUSSCHER, HJ
    WEERKAMP, AH
    JOURNAL OF MICROBIOLOGICAL METHODS, 1989, 9 (02) : 73 - 78
  • [45] Measuring impact of a quality improvement initiative on glaucoma clinic flow using an automated real-time locating system
    John A. Musser
    Juno Cho
    Amy Cohn
    Leslie M. Niziol
    Dena Ballouz
    David T. Burke
    Paula Anne Newman-Casey
    BMC Ophthalmology, 22
  • [46] Real-time measurement of flow rate in microfluidic devices using a cantilever-based optofluidic sensor
    Cheri, Mohammad Sadegh
    Latifi, Hamid
    Sadeghi, Jalal
    Moghaddam, Mohammadreza Salehi
    Shahraki, Hamidreza
    Hajghassem, Hasan
    ANALYST, 2014, 139 (02) : 431 - 438
  • [47] Real-time measurement of constituents in solid materials using particle flow spark induced breakdown spectroscopy
    Yao, Shunchun
    Xu, Jialong
    Zhang, Xiang
    Zhang, Lifeng
    Lu, Zhimin
    Lu, Jidong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 986 - 991
  • [48] Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound
    Kalantarinia, Kambiz
    Belcik, J. Todd
    Patrie, James T.
    Wei, Kevin
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2009, 297 (04) : F1129 - F1134
  • [49] Real-time distortion measurement in a slab structure using hetero-core fiber optic embedded sensors
    Nishiyama, M
    Sasaki, H
    Watanabe, K
    17th International Conference on Optical Fibre Sensors, Pts 1 and 2, 2005, 5855 : 791 - 794
  • [50] Real-time transverse force sensing using fiber Bragg grating through direct Stokes parameters measurement
    Su, Yang
    Zhu, Yong
    Zhang, Baofu
    Zhou, Hua
    OPTICS EXPRESS, 2015, 23 (25): : 32300 - 32310