Accuracy of automated analyzers for the estimation of CSF cell counts: A systematic review and meta-analysis

被引:1
|
作者
Waldrop, Greer E. [1 ]
Cocuzzo, Kaitlyn [1 ]
Schneider, Colleen L. [2 ]
Kim, Carla Y. [1 ]
Goetz, Teddy G. [1 ]
Chomba, Mashina S. [1 ,3 ,4 ]
Delaurentis, Clare E. [5 ]
Smithgall, Marie C. [6 ]
Francis, Richard O. [7 ]
Thakur, Kiran T. [1 ]
机构
[1] Columbia Univ, Irving Med Ctr, New York Presbyterian Hosp, Dept Neurol, 710 West 168th St, New York, NY 10032 USA
[2] Univ Rochester, Sch Med & Dent, Med Scientist Training Program, Rochester, NY USA
[3] Univ Teaching Hosp, Sch Med, Lusaka, Zambia
[4] Univ Zambia, Lusaka, Zambia
[5] Columbia Univ, Dept Infect Dis, Irving Med Ctr, New York, NY USA
[6] Weill Cornell Med, Dept Pathol, New York, NY USA
[7] Columbia Univ, Vagelos Coll Phys & Surg, Dept Pathol & Cell Biol, New York, NY USA
关键词
automated analyzers; cerebrospinal fluid; lumbar puncture; manual microscopy; pleocytosis; BODY-FLUID MODE; FLOW-CYTOMETRIC ANALYSIS; CEREBROSPINAL-FLUID; HEMATOLOGY ANALYZER; BLOOD-CELLS; PERFORMANCE EVALUATION; SYSMEX XE-5000; MODULE; WHITE; XN-1000;
D O I
10.1111/ijlh.14236
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This systematic review evaluates the evidence for accuracy of automated analyzers that estimate cerebrospinal fluid (CSF) white blood cell counts (WBC) compared to manual microscopy. Inclusion criteria of original research articles included human subjects, English language, and manual microscopy comparator. PUBMED, EMBASE and Cochrane Review databases were searched through 2019 and QUADAS-2 Tool was used for assessment of bias. Data were pooled and analyzed by comparison method, using random effects estimation. Among 652 titles, 554 abstracts screened, 104 full-text review, 111 comparisons from 41 studies were included. Pooled estimates of sensitivity and specificity (n = 7) were 95% (95%-CI 93%-97%) and 84% (95%-CI: 64%-96%), respectively. Pooled R-2 estimates (n = 29) were 0.95 (95%-CI: 0.95-0.96); Pooled spearman rho correlation (n = 27) estimates were 0.95 (95% CI 0.95-0.96). Among those comparisons using Bland-Altman analysis (n = 11) pooled mean difference was estimated at 0.98 (95% CI-0.54-2.5). Among comparisons using Passing-Bablok regressions (n = 14) the pooled slope was estimated to be 1.05 (95% CI 1.03-1.07). Q tests of homogeneity were all significant with the exception of the Bland-Altman comparisons (I-2 10%, p value 0.35). There is good overall accuracy for CSF WBC by automated hematologic analyzers. These findings are limited by the small sample sizes and inconsistent validation methodology in the reviewed studies.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 50 条
  • [31] Effect of Exercise on Acute Senescent Lymphocyte Counts: A Systematic Review and Meta-Analysis
    Sardeli, Amanda Veiga
    Mori, Marcelo A.
    Lord, Janet M.
    GERONTOLOGY, 2022,
  • [32] Accuracy level of Haavikko's dental age estimation method in children: A systematic review and meta-analysis
    Singh, Monika
    Sehrawat, J. S.
    Sharma, Vishal
    ROMANIAN JOURNAL OF LEGAL MEDICINE, 2018, 26 (04): : 397 - 402
  • [33] Probiotics reduce mutans streptococci counts in humans: a systematic review and meta-analysis
    Laleman, Isabelle
    Detailleur, Valentine
    Slot, Dagmar Else
    Slomka, Vera
    Quirynen, Marc
    Teughels, Wim
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1539 - 1552
  • [34] Probiotics reduce mutans streptococci counts in humans: a systematic review and meta-analysis
    Isabelle Laleman
    Valentine Detailleur
    Dagmar Else Slot
    Vera Slomka
    Marc Quirynen
    Wim Teughels
    Clinical Oral Investigations, 2014, 18 : 1539 - 1552
  • [35] Diagnostic Accuracy of MRI for Detection of Papillary Renal Cell Carcinoma: A Systematic Review and Meta-Analysis
    Chiarello, Matthew A.
    Mali, Rahul D.
    Kang, Stella K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 812 - 821
  • [36] Accuracy of automated 3D cephalometric landmarks by deep learning algorithms: systematic review and meta-analysis
    Serafin, Marco
    Baldini, Benedetta
    Cabitza, Federico
    Carrafiello, Gianpaolo
    Baselli, Giuseppe
    Del Fabbro, Massimo
    Sforza, Chiarella
    Caprioglio, Alberto
    Tartaglia, Gianluca M.
    RADIOLOGIA MEDICA, 2023, 128 (05): : 544 - 555
  • [37] Accuracy of automated 3D cephalometric landmarks by deep learning algorithms: systematic review and meta-analysis
    Marco Serafin
    Benedetta Baldini
    Federico Cabitza
    Gianpaolo Carrafiello
    Giuseppe Baselli
    Massimo Del Fabbro
    Chiarella Sforza
    Alberto Caprioglio
    Gianluca M. Tartaglia
    La radiologia medica, 2023, 128 : 544 - 555
  • [38] Estimation of the worldwide seroprevalence of cytomegalovirus: A systematic review and meta-analysis
    Zuhair, Mohamed
    Smit, G. Suzanne A.
    Wallis, Gabriel
    Jabbar, Faiz
    Smith, Colette
    Devleesschauwer, Brecht
    Griffiths, Paul
    REVIEWS IN MEDICAL VIROLOGY, 2019, 29 (03)
  • [39] Body size estimation in obesity: a systematic review and meta-analysis
    Tagini, Sofia
    Scarpina, Federica
    Zampini, Massimiliano
    EXPERIMENTAL BRAIN RESEARCH, 2021, 239 (12) : 3417 - 3429
  • [40] Body size estimation in obesity: a systematic review and meta-analysis
    Sofia Tagini
    Federica Scarpina
    Massimiliano Zampini
    Experimental Brain Research, 2021, 239 : 3417 - 3429