Simultaneous time-of-flight MR angiography and quantitative susceptibility mapping with key time-of-flight features

被引:0
作者
De, Ashmita [1 ]
Grenier, Justin [1 ]
Wilman, Alan H. [1 ,2 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
基金
加拿大健康研究院;
关键词
quantitative susceptibility mapping; susceptibility-weighted imaging; time-of-flight MR angiography; MAGNETIC-RESONANCE ANGIOGRAPHY; BRAIN; ACQUISITION; VENOGRAPHY; SEQUENCE; ARTERIES; VOLUME; VEINS; IRON; SWI;
D O I
10.1002/nbm.5079
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A technique for combined time-of-flight (TOF) MR angiography (MRA) and quantitative susceptibility mapping (QSM) was developed with key features of standard three-dimensional (3D) TOF acquisitions, including multiple overlapping thin slab acquisition (MOTSA), ramped RF excitation, and venous saturation. The developed triple-echo 3D TOF-QSM sequence enabled TOF-MRA, susceptibility-weighted imaging (SWI), QSM, and R2* mapping. The effects of ramped RF, resolution, flip angle, venous saturation, and MOTSA were studied on QSM. Six volunteers were scanned at 3 T with the developed sequence, conventional TOF-MRA, and conventional SWI. Quantitative comparison of susceptibility values on QSM and normalized arterial and venous vessel-to-background contrasts on TOF and SWI were performed. The ramped RF excitation created an inherent phase variation in the raw phase. A generic correction factor was computed to remove the phase variation to obtain QSM without artifacts from the TOF-QSM sequence. No statistically significant difference was observed between the developed and standard QSM sequence for susceptibility values. However, maintaining standard TOF features led to compromises in signal-to-noise ratio for QSM and SWI, arising from the use of MOTSA rather than one large 3D slab, higher TOF spatial resolution, increased TOF background suppression due to larger flip angles, and reduced venous signal from venous saturation. In terms of vessel contrast, veins showed higher normalized contrast on SWI derived from TOF-QSM than the standard SWI sequence. While fast flowing arteries had reduced contrast compared with standard TOF-MRA, no statistical difference was observed for slow flowing arteries. Arterial contrast differences largely arise from the longer TR used in TOF-QSM over standard TOF-MRA to accommodate additional later echoes for SWI. In conclusion, although the sequence has a longer TR and slightly lower arterial contrast, provided an adequate correction is made for ramped RF excitation effects on phase, QSM may be performed from a multiecho sequence that includes all key TOF features, thus enabling simultaneous TOF-MRA, SWI, QSM, and R2* map computation. A triple-echo 3D sequence was developed with key time-of-flight (TOF) MR angiography (MRA) features, including ramped RF excitation, venous saturation, and multiple overlapping thin slab acquisition (MOTSA), enabling TOF-MRA, susceptibility-weighted imaging (SWI), quantitative susceptibility mapping (QSM), and transverse relaxation rate (R2*) mapping. The effects of TOF features on QSM were studied.image
引用
收藏
页数:13
相关论文
共 47 条
[1]   Dual-Echo Arteriovenography Imaging with 7T MRI [J].
Bae, Kyongtae Ty ;
Park, Sung-Hong ;
Moon, Chan-Hong ;
Kim, Jung-Hwan ;
Kaya, Diana ;
Zhao, Tiejun .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) :255-261
[2]   Susceptibility-Weighted Imaging: Clinical Angiographic Applications [J].
Barnes, Samuel R. S. ;
Haacke, E. Mark .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2009, 17 (01) :47-+
[3]   Simultaneous imaging of radiation-induced cerebral microbleeds, arteries and veins, using a multiple gradient echo sequence at 7 Tesla [J].
Bian, Wei ;
Banerjee, Suchandrima ;
Kelly, Douglas A. C. ;
Hess, Christopher P. ;
Larson, Peder E. Z. ;
Chang, Susan M. ;
Nelson, Sarah J. ;
Lupo, Janine M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) :269-279
[4]   CEREBRAL MR-ANGIOGRAPHY WITH MULTIPLE OVERLAPPING THIN SLAB ACQUISITION .1. QUANTITATIVE-ANALYSIS OF VESSEL VISIBILITY [J].
BLATTER, DD ;
PARKER, DL ;
ROBISON, RO .
RADIOLOGY, 1991, 179 (03) :805-811
[5]   Susceptibility-weighted angiography (SWAN) of cerebral veins and arteries compared to TOF-MRA [J].
Boeckh-Behrens, T. ;
Lutz, J. ;
Lummel, N. ;
Burke, M. ;
Wesemann, T. ;
Schoepf, V. ;
Brueckmann, H. ;
Linn, J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (06) :1238-1245
[6]   Quantitative Susceptibility Mapping of Intracerebral Hemorrhages at Various Stages [J].
Chang, Shixin ;
Zhang, Jingwei ;
Liu, Tian ;
Tsiouris, Apostolos John ;
Shou, Jian ;
Thanh Nguyen ;
Leifer, Dana ;
Wang, Yi ;
Kovanlikaya, Ilhami .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (02) :420-425
[7]   Enhanced susceptibility-weighted angiography (ESWAN) of cerebral arteries and veins at 1.5 Tesla [J].
Chen, L. ;
Zhang, J. ;
Wang, Q-X ;
Peng, L. ;
Luo, X. ;
Zhu, W-Z ;
Roshan, A. K. ;
Qi, J-P ;
Wang, H. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1039)
[8]   The use of Fourier-domain analyses for unwrapping phase images of low SNR [J].
Chen, Nan-kuei ;
Wu, Pei-Hsin .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) :356-366
[9]   An interleaved sequence for simultaneous magnetic resonance angiography (MRA), susceptibility weighted imaging (SWI) and quantitative susceptibility mapping (QSM) [J].
Chen, Yongsheng ;
Liu, Saifeng ;
Buch, Sagar ;
Hu, Jiani ;
Kang, Yan ;
Haacke, E. Mark .
MAGNETIC RESONANCE IMAGING, 2018, 47 :1-6
[10]   Imaging the Nigrosome 1 in the substantia nigra using susceptibility weighted imaging and quantitative susceptibility mapping: An application to Parkinson's disease [J].
Cheng, Zenghui ;
He, Naying ;
Huang, Pei ;
Li, Yan ;
Tang, Rongbiao ;
Sethi, Sean K. ;
Ghassaban, Kiarash ;
Yerramsetty, Kiran Kumar ;
Palutla, Vinay Kumar ;
Chen, Shengdi ;
Yan, Fuhua ;
Haacke, E. Mark .
NEUROIMAGE-CLINICAL, 2020, 25