Rapid electrical impedance detection of sickle cell vaso-occlusion in microfluidic device

被引:2
作者
Qiang, Yuhao [1 ]
Dieujuste, Darryl [1 ]
Liu, Jia [1 ]
Alvarez, Ofelia [2 ]
Du, E. [1 ]
机构
[1] Florida Atlantic Univ, Dept Ocean & Mech Engn, Boca Raton, FL 33431 USA
[2] Univ Miami, Div Pediat Hematol & Oncol, Miami, FL 33136 USA
关键词
Sickle cell disease; Hypoxia; Electrical impedance; Vaso-occlusion; Microfluidics; FLOW-CYTOMETRY; DISEASE; HEMOGLOBIN;
D O I
10.1007/s10544-023-00663-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Sickle cell disease is characterized by painful vaso-occlusive crises, in which poorly deformable sickle cells play an important role in the complex vascular obstruction process. Existing techniques are mainly based on optical microscopy and video processing of sickle blood flow under normoxic condition, for measuring vaso-occlusion by a small fraction of dense sickle cells of intrinsic rigidity but not the vaso-occlusion by the rigid, sickled cells due to deoxygenation. Thus, these techniques are not suitable for rapid, point-of-care testing. Here, we integrate electrical impedance sensing and Polydimethylsiloxane-microvascular mimics with controlled oxygen level into a single microfluidic chip, for quantification of vaso-occlusion by rigid, sickled cells within 1 min. Electrical impedance measurements provided a label-free, real-time detection of different sickle cell flow behaviors, including steady flow, vaso-occlusion, and flow recovery in response to the deoxygenation-reoxygenation process that are validated by microscopic videos. Sensitivity of the real part and imaginary part of the impedance signals to the blood flow conditions in both natural sickle cell blood and simulants at four electrical frequencies (10, 50, 100, and 500 kHz) are compared. The results show that the sensitivity of the sensor in detection of vaso-occlusion decreases as electrical frequency increases, while the higher frequencies are preferable in measurement of steady flow behavior. Additional testing using sickle cell simulants, chemically crosslinked normal red blood cells, shows same high sensitivity in detection of vaso-occlusion as sickle cell vaso-occlusion under deoxygenation. This work enables point-of-care testing potentials in rapid, accurate detection of steady flow and sickle cell vaso-occlusion from microliter volume blood specimens. Quantification of sickle cell rheology in response to hypoxia, may provide useful indications for not only the kinetics of cell sickling, but also the altered hemodynamics as obseved at the microcirculatory level.
引用
收藏
页数:12
相关论文
共 50 条
[41]   MEASUREMENT OF ELECTRICAL PROPERTIES OF SICKLE CELLS FROM ELECTRICAL IMPEDANCE OF CELL SUSPENSION [J].
Liu, Jia ;
Qiang, Yuhao ;
Du, E. .
PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
[42]   A portable microfluidic in vitro diagnostic device for rapid detection of procalcitonin [J].
Yang, Yujing ;
Dou, Xinyao ;
Zhang, Taiyi ;
Xu, Zhipeng ;
Wang, Yanting ;
Cai, Gaozhe ;
Huang, Xiaowen ;
Liu, Bo .
NANOTECHNOLOGY AND PRECISION ENGINEERING, 2025, 8 (04)
[43]   Electrical Impedance Determination of Cancer Cell Viability in a 3-Dimensional Cell Culture Microfluidic Chip [J].
Lei, Kin Fong ;
Wu, Min-Hsien ;
Hsu, Che-Wei ;
Chen, Yi-Dao .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (12) :12817-12828
[44]   Exploring the role of viscosity-vaso-occlusion and haemolysis-endothelial dysfunction in pain sensitization among Jamaicans with sickle cell disease [J].
Ramsay, Zachary ;
Ali, Amza ;
Grant, Justin ;
Asnani, Monika .
BRITISH JOURNAL OF HAEMATOLOGY, 2024, 205 (04) :1570-1580
[45]   A microfluidic-informatics assay for quantitative physical occlusion measurement in sickle cell disease [J].
Zhang, Xingjian ;
Chan, Trevor ;
Carbonella, Judith ;
Gong, Xiangyu ;
Ahmed, Noureen ;
Liu, Chang ;
Demandel, Israel ;
Zhang, Junqi ;
Pashankar, Farzana ;
Mak, Michael .
LAB ON A CHIP, 2022, 22 (06) :1126-1136
[46]   Development of microfluidic device for electrical/physical characterization of single cell [J].
Cho, YH ;
Yamamoto, T ;
Sakai, Y ;
Fujii, T ;
Kim, B .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (02) :287-295
[47]   Application of Microfluidic Impedance Cytometer in Single-Cell Detection [J].
Feng, Di ;
Wang, Guanghua ;
Tang, Wenlai ;
Yang, Jiquan .
PROGRESS IN CHEMISTRY, 2021, 33 (04) :555-567
[48]   A compact and low cost microfluidic cell impedance detection system [J].
Mei, Zhe ;
Liu, Zhiwen ;
Zhou, Zhiguo .
AIMS BIOPHYSICS, 2016, 3 (04) :596-608
[49]   Label-free microfluidic cell sorting and detection for rapid blood analysis [J].
Lu, Nan ;
Tay, Hui Min ;
Petchakup, Chayakorn ;
He, Linwei ;
Gong, Lingyan ;
Maw, Kay Khine ;
Leong, Sheng Yuan ;
Lok, Wan Wei ;
Ong, Hong Boon ;
Guo, Ruya ;
Li, King Ho Holden ;
Hou, Han Wei .
LAB ON A CHIP, 2023, 23 (05) :1226-1257
[50]   Dynamic monitoring of single cell lysis in an impedance-based microfluidic device [J].
Zhou, Ying ;
Basu, Srinjan ;
Laue, Ernest D. ;
Seshia, Ashwin A. .
BIOMEDICAL MICRODEVICES, 2016, 18 (04)