Research on the Influence of Modulation Depth of Phase Sensitive Detection on Stimulated Raman Signal Intensity and Signal-to-Noise Ratio

被引:0
作者
Pan Ke-yu [1 ,2 ]
Zhu Ming-yao [1 ,2 ]
Wang Yi-meng [1 ,2 ]
Xu, Yang [1 ]
Chi Ming-bo [1 ,2 ]
Wu Yi-hui [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Precis Machinery & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Phase sensitive detection; Stimulated Raman scattering; Modulation depth; Signal Intensity; Signal-to-Noise ratio; Optimum optical power ratio;
D O I
10.3964/j.issn.1000-0593(2023)04-1068-07
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
timulated Raman scattering is one of coherent Raman scattering. The signal generated by stimulated Raman scattering is significantly enhanced under the third-order nonlinear effect, and there is no interference from non-resonant background. Its spectrum is almost consistent with the spontaneous Raman spectrum. Therefore, the micro-imaging technology based on stimulated Raman scattering has the advantages of no labeling, high specificity and being non-invasive. It has been successfully used in biological cell imaging and has made many great achievements. Stimulated Raman signal has the same wavelength as excitation luminescence and is easily disturbed by excitation luminescence background noise. In order to solve this problem, the combination of optical modulation and phase-sensitive detection is often used to detect it. In the detection process, modulation depth influences the intensity and signal-to-noise ratio of the stimulated Raman signal. Because of this, this paper deeply analyzes the influence of modulation depth on stimulated Raman signal intensity and signal-to-noise ratio based on relevant theories. At the same time, considering the limitation of cell photodamage threshold on the sum of two excitation optical powers in applications such as bio-spectral imaging, the excitation optical power configuration method to obtain the maximum signal intensity and the best signal-to-noise ratio at different modulation depths is analyzed. By establishing a stimulated Raman experimental system, dimethyl sulfoxide is taken as the research object for experimental verification. The results show that when the stimulated Raman loss is detected under the limitation of photodamage threshold, at the same modulation depth, the signal intensity reaches the strongest when the optical power ratio of pump light to the one of stokes light is 1:1,and the signal-to-noise ratio reaches the best when the ratio is 1:2. When the optical power ratio of pump light to the one of stokes light is the same, the intensity and signal-to-noise ratio of stimulated Raman signal decrease with the decrease of modulation depth, and the correlation is approximately linear. The stimulated Raman spectrum of dimethyl sulfoxide obtained from the experiment also verified that the higher the modulation depth, the stronger the spectral signal and the better the signal-to-noise ratio and the better the spectral quality of the whole sample. The research results are the improvement of stimulated Raman microscopy in signal modulation and detection and can provide reference guidance for stimulated Raman spectroscopy detection and cell imaging experiments.
引用
收藏
页码:1068 / 1074
页数:7
相关论文
共 15 条
[1]   Noise in stimulated Raman scattering measurement: From basics to practice [J].
Audier, X. ;
Heuke, S. ;
Volz, P. ;
Rimke, I. ;
Rigneault, H. .
APL PHOTONICS, 2020, 5 (01)
[2]   The Seventh Sino-US Chemistry Professors Conference: Bridging International Research Communities in Chemistry Preface [J].
Chen Xi ;
Suo Zucai ;
Huang Zhen ;
Pu Lin .
SCIENCE CHINA-CHEMISTRY, 2012, 55 (01) :1-2
[3]  
Cheng Jixin, 2013, COHERENT RAMAN SCATT, V7, P219
[4]  
FEI Ye-tai, 2015, THEORY ERROR DATA PR, V7th
[5]   Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy [J].
Freudiger, Christian W. ;
Min, Wei ;
Saar, Brian G. ;
Lu, Sijia ;
Holtom, Gary R. ;
He, Chengwei ;
Tsai, Jason C. ;
Kang, Jing X. ;
Xie, X. Sunney .
SCIENCE, 2008, 322 (5909) :1857-1861
[6]   Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy [J].
Fu, Y ;
Wang, HF ;
Shi, RY ;
Cheng, JX .
OPTICS EXPRESS, 2006, 14 (09) :3942-3951
[7]  
GAO Jin-zhan, 2019, DETECTION WEAK SIGNA, V47, P190
[8]  
Guo X Y, 2021, Journal of Fuzhou University (Natural Science Edition), V49, P135
[9]  
Li ZL, 2020, CHIN J LASERS, V47, DOI [10.3788/CJL202017.0207005, 10.3788/CJL202047.0207005]
[10]  
MIN Wei, 2020, OPTICS OPTOELECTRONI, P1