Vault Height Is a Key Predictive Factor for Anterior Segment Measurement Error by IOLMaster 700 in Eyes With Phakic Intraocular Lens

被引:1
|
作者
Zhang, Jiaqing [1 ,2 ]
Chen, Fei [1 ,2 ]
Han, Xiaotong [1 ,2 ]
Qiu, Xiaozhang [1 ,2 ]
Liu, Zhenzhen [1 ,2 ]
Chen, Xiaoyun [1 ,2 ]
Jin, Guangming [1 ,2 ]
Qu, Bo [3 ]
Yao, Huan [1 ,2 ]
Ye, Yiming [1 ,2 ]
Yu, Keming [1 ,2 ]
Tan, Xuhua [1 ,2 ]
Luo, Lixia [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Peoples R China
[3] Peking Univ Third Hosp, Beijing, Peoples R China
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2023年 / 12卷 / 09期
基金
中国国家自然科学基金;
关键词
phakic intraocular lens; biometry; anterior chamber depth; vault height; IMPLANTABLE COLLAMER LENS; LOW-TO-MODERATE; CHAMBER DEPTH; BIOMETRY;
D O I
10.1167/tvst.12.9.16
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify risk factors of ocular anterior segment measurement error by the IOLMaster 700 in eyes implanted with an implantable Collamer lens (ICL). Methods: In total, 152 patients with clear lens (152 eyes, group 1) and another 32 cataract patients (57 eyes, group 2) who underwent ICL implantation were included, and the presence of measurement error by the IOLMaster 700 was determined based on B-scan images. The risk factors for measurement error were evaluated by logistic regression, and the optimal threshold was determined using receiver operating characteristic analysis. Results: The ICL was misidentified as the anterior surface of the crystalline lens in 51.97% of eyes (79/152) in group 1 and 80.70% of eyes (46/57) in group 2. For every 100-mu m decrease in the vault height, a 3.57- and 5.78-fold increase in the risk of measurement error was observed in group 1 and group 2, respectively. We identified an optimal threshold of the vault height at 389.47 mu m for predicting biometric measurement error in eyes implanted with ICL, which showed an area under the curve of 0.93 (95% confidence interval, 0.90-0.97), a sensitivity of 0.87, and a specificity of 0.86. Conclusions: Patients with ICL implantation, particularly those with a vault height less than 389.47 mu m, are at a greater risk of anterior segment biometric measurement error by the IOLMaster 700. Translational Relevance: The threshold of vault height can help to identify high-risk patients and further optimize biometric measurement.
引用
收藏
页数:8
相关论文
empty
未找到相关数据