Development of two highly sensitive and selective sensor-assisted fluorescence immunoassays for trace determination of copper residues in food samples

被引:4
作者
Darwish, Ibrahim A. [1 ]
Wang, Zongzhi [2 ]
Darling, Ryhan J. [3 ]
Alzoman, Nourah Z. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, POB 2457, Riyadh 11451, Saudi Arabia
[2] Chinese Acad Sci, Inst Hydrobiol, State Key Lab Freshwater Ecol & Biotechnol, Wuhan, Peoples R China
[3] Med Coll Wisconsin, Dept Biochem, Milwaukee, WI 53226 USA
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; TOXIC ELEMENTS; ASSAYS; IONS;
D O I
10.1039/d3ra04415g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study describes the development of two highly sensitive and selective sensor-assisted fluorescence immunoassays for the trace determination of copper ions, Cu(ii) residues, in food samples. These assays were the microwell-based fluoroimmuoassay (FIA) and the kinetic exclusion assay (KinExA). FIA and KinExA were assisted by a microplate reader and a KinExA (TM) 3200 immunosensor, respectively. Both FIA and KinExA were developed utilizing the same antibody, capturing reagent, and fluorescence signal-generating reagent. The antibody was a mouse monoclonal antibody, designated as 8D66, that specifically recognized the Cu(ii)-ethylenediaminetetraacetic acid complex (Cu(ii)-EDTA) but did not recognize Cu(ii)-free EDTA. The capturing reagent was Cu(ii)-EDTA covalently linked to bovine serum albumin protein (Cu(ii)-EDTA-BSA). The fluorescence-generating reagent was an anti-mouse IgG conjugated with fluorescein isothiocyanate (IgG-FITC). Both FIA and KinExA involved competitive binding reactions between Cu(ii)-EDTA complexes, formed in the sample solution, and Cu(ii)-EDTA-BSA conjugate which has been immobilized onto microwell fluorescence assay plates (in FIA) or polymethylmethacrylate beads (in KinExA) for a limited quantity of binding sites of 8D66 antibody. The conditions of both FIA and KinExA were investigated, and the optimum procedures were established. Both FIA and KinExA were validated, and all validation parameters were acceptable. Many different metal ions that are commonly encountered in food samples did not interfere with Cu(ii) analysis by both FIA and KinExA. Both assays were applied to the determination of Cu(ii) in food samples with satisfactory accuracy and precision. Both assays were compared favorably with inductively coupled plasma atomic emission spectroscopy. Comparative evaluation of FIA and KinExA revealed that KinExA had higher sensitivity and better precision than FIA, whereas, both assays had comparable accuracy. Both FIA and KinExA were superior to the existing atomic spectrometric methods for Cu(ii). The proposed FIA and KinExA are anticipated to effectively contribute to assessing Cu(ii) concentrations and controlling the exposure of humans to its potential toxicities. This study describes the development of two highly sensitive and selective sensor-assisted fluorescence immunoassays for the trace determination of copper ions, Cu(ii) residues, in food samples.
引用
收藏
页码:29195 / 29205
页数:11
相关论文
共 48 条
  • [1] Determination of Copper in Food and Water by Dispersive Liquid-Liquid Microextraction and Flame Atomic Absorption Spectrometry
    Al Othman, Zeid
    Unsal, Yunus Emre
    Habila, Mohamed
    Shabaka, Aza
    Tuzen, Mustafa
    Soylak, Mustafa
    [J]. ANALYTICAL LETTERS, 2015, 48 (11) : 1738 - 1750
  • [2] Spectrophotometric Determination of Trace Concentrations of Copper in Waters Using the Chromogenic Reagent 4-Amino-3-Mercapto-6-[2-(2-Thienyl)Vinyl]-1,2,4-Triazin-5(4H)-One: Synthesis, Characterization, and Analytical Applications
    Alharthi, Salman S.
    Al-Saidi, Hamed M.
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (11):
  • [3] Immunoassays for metal ions
    Blake, DA
    Blake, RC
    Khosraviani, M
    Pavlov, AR
    [J]. ANALYTICA CHIMICA ACTA, 1998, 376 (01) : 13 - 19
  • [4] Automated kinetic exclusion assays to quantify protein binding interactions in homogeneous solution
    Blake, RC
    Pavlov, AR
    Blake, DA
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 272 (02) : 123 - 134
  • [5] BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
  • [6] Branislav S., 2021, J. Food Process. Preserv, V45
  • [7] Sub-Lethal Effects of Copper to Benthic Invertebrates Explained by Sediment Properties and Dietary Exposure
    Campana, Olivia
    Simpson, Stuart L.
    Spadaro, David A.
    Blasco, Julian
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (12) : 6835 - 6842
  • [8] ENZYME-IMMUNOASSAY TO DETERMINE HEAVY-METALS USING ANTIBODIES TO SPECIFIC METAL-EDTA COMPLEXES - OPTIMIZATION AND VALIDATION OF AN IMMUNOASSAY FOR SOLUBLE INDIUM
    CHAKRABARTI, P
    HATCHER, FM
    BLAKE, RC
    LADD, PA
    BLAKE, DA
    [J]. ANALYTICAL BIOCHEMISTRY, 1994, 217 (01) : 70 - 75
  • [9] Copper Development Association Inc, Uses of Copper Compounds: Agricultural Uses
  • [10] Soil copper uptake by land snails: A semi-field experiment with juvenile Cantareus aspersus snails
    Draghici, George Andrei
    Dehelean, Cristina
    Pinzaru, Iulia
    Bordean, Despina Maria
    Borozan, Aurica
    Tsatsakis, Aristides Michael
    Kovatsi, Leda
    Nica, Dragos
    [J]. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY, 2019, 72