Monitoring SF6 Gas Leakage Based on a Customized Binocular System

被引:2
|
作者
Si, Wenrong [1 ]
Zhao, Yingying [1 ]
Wang, Yan [2 ,3 ]
Li, Ben [2 ,3 ]
Tong, Geng [2 ,3 ]
Yu, Yiting [2 ,3 ]
机构
[1] State Grid Shanghai Elect Power Res Inst, Shanghai 200437, Peoples R China
[2] Northwestern Polytech Univ, Sch Mech Engn, Ningbo Inst, Xian 710072, Peoples R China
[3] Northwestern Polytech Univ, Key Lab Micro Nano Syst Aerosp, Key Lab Microand Nanoelectro Mech Syst Shaanxi Pro, Minist Educ, Xian 710072, Peoples R China
关键词
infrared imaging; customized; binocular system; SF6 gas detection; SENSOR;
D O I
10.3390/s24030993
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sulfur hexafluoride (SF6) gas is extensively utilized as an insulating and arc-quenching medium in the circuit breakers and isolating switches of electrical equipment. It effectively isolates the circuits from the atmosphere and promptly extinguishes arcs. Therefore, the issue of SF6 gas leakage poses a significant threat to the related application fields, and the detection of SF6 gas leakage becomes extremely important. Infrared imaging detection offers advantages including non-contact, high precision, and visualization. However, most existing infrared detection systems are equipped with only one filter to detect SF6 gas. The images captured contain background noise and system noise, making these systems vulnerable to interference from such noises. To address these issues, we propose a method for monitoring SF6 gas leakage based on a customized binocular imaging (CBI) system. The CBI system has two filters, greatly reducing the interference of system noise and background noise. The first filter features the absorption resonant peak of SF6 gas. The second filter is used to record background noise and system noise. One aspect to note is that, in order to avoid the interference of other gases, the central wavelength of this second filter should keep away from the absorption resonant peaks of those gases. Accordingly, the central wavelengths of our customized filters were determined as 10,630 nm and 8370 nm, respectively. Then, two cameras of the same type were separately assembled with a customized filter, and the CBI prototype was accomplished. Finally, we utilized the difference method using two infrared images captured by the CBI system, to monitor the SF6 gas leakage. The results demonstrate that our developed system achieves a high accuracy of over 99.8% in detecting SF6 gas. Furthermore, the CBI system supports a plug-and-play customization to detect various gases for different scenarios.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Monitoring of SF6 gas admixtures in gas-insulated electrical equipment
    Paul, Th. A.
    Kramer, A.
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 493 - 496
  • [22] Early SF6 Gas Leakage Detection Through a Novel Comparison Algorithm Based on Pressure Only
    Lindskog, Anders
    Neandhers, Kristoffer
    Thiringer, Torbjorn
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (02) : 922 - 930
  • [23] Gravimetric Standard Gas Mixtures for Global Monitoring of Atmospheric SF6
    Lim, Jeong Sik
    Lee, Jinbok
    Moon, Dongmin
    Kim, Jin Seog
    Lee, Jeongsoon
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12068 - 12075
  • [24] DC DIELECTRIC STRENGTH OF A SF6 GAS INSULATED SYSTEM
    MENJU, S
    TAKAHASHI, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (01): : 217 - 224
  • [25] Speckle noise reduction algorithm for infrared image of gas leakage in SF6 switcher
    Xu, Yuanzhe
    He, Ye
    Guo, Haitao
    Li, Huimin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2011, 32 (12): : 2669 - 2673
  • [26] Technology of leakage-gas blocking with pressure in SF6 insulated power apparatus
    Shanghai Electric Power Corporation, Shanghai 200030, China
    不详
    Gaoya Dianqi, 2007, 5 (378-379+383):
  • [27] Gas-insulated switchgear state monitoring based on SF6 decomposition products detection
    Yan, Xianglian
    Song, Gao
    Wang, Chengyu
    Ji, Yansong
    Yang, Ren
    Jian, Yongfeng
    Liu, Hanmei
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (06): : 83 - 88
  • [28] SF6 GAS NEW INSULATOR
    HAMPTON, BF
    ENGINEERING, 1977, 217 (02): : 116 - 118
  • [29] ON THE TOXICITY OF SF6 INSULATING GAS
    WOCK, S
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1984, 19 (02): : 156 - 156
  • [30] ON THE TOXICITY OF SF6 INSULATING GAS
    VANROGGEN, A
    PUGH, PF
    BRAND, KP
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1983, 18 (01): : 93 - 93