Safety and success of transvenous lead extraction using excimer laser sheaths: a meta-analysis of over 1700 patients

被引:6
作者
Rinaldi, Christopher Aldo [1 ,2 ]
Diemberger, Igor [3 ,4 ]
Biffi, Mauro [4 ]
Gao, Yu-Rong [5 ]
Sizto, Enoch [5 ]
Jin, Nancy [5 ]
Epstein, Laurence M. [6 ]
Defaye, Pascal [7 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Cardiovasc Dept, Lambeth Palace Rd, London SE1 7EH, England
[2] Cleveland Clin London, Heart Vasc & Thorac Inst, 33 Grosvenor Pl, London SW1X 7HY, England
[3] Univ Bologna, Dept Med & Surg Sci, Policlin S Orsola Malpighi, Via Massarenti 9, I-40138 Bologna, Italy
[4] IRCCS Azienda Osped Univ Bologna, Cardiol Unit, Policlin S Orsola Malpighi, Via Massarenti 9, I-40138 Bologna, Italy
[5] Philips North Amer LLC, Image Guided Therapy, Cambridge, MA USA
[6] Northwell Hlth, Dept Cardiol, Manhasset, NY USA
[7] Univ Hosp Grenoble Alpes, Dept Cardiol, Grenoble, France
来源
EUROPACE | 2023年 / 25卷 / 11期
关键词
Cardiac implantable electronic devices; Excimer laser sheath; SLS II; GlideLight; Transvenous lead extraction; EXPERT CONSENSUS STATEMENT; CONTROLLED ELECTRA; DEFIBRILLATOR LEADS; EXPERIENCE; MANAGEMENT; MORTALITY; REGISTRY; DIFFERENCE; VEGETATION; REMOVAL;
D O I
10.1093/europace/euad298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims While numerous studies have demonstrated favourable safety and efficacy of the excimer laser sheath for transvenous lead extraction (TLE) in smaller cohorts, comprehensive large-scale investigations with contemporary data remain scarce. This study aims to evaluate the safety and performance of laser-assisted TLE through a meta-analysis of contemporary data.Methods and results A systematic literature search was conducted to identify articles that assessed the safety and performance of the spectranetics laser sheath (SLS) II and GlideLight Excimer laser sheaths in TLE procedures between 1 April 2016 and 31 March 2021. Safety outcomes included procedure-related death and major/minor complications. Performance outcomes included procedural and clinical success rates. A random-effects, inverse-variance-weighting meta-analysis was performed to obtain the weighted average of the evaluated outcomes. In total, 17 articles were identified and evaluated, including 1729 patients with 2887 leads. Each patient, on average, had 2.3 +/- 0.3 leads with a dwell time of 7.9 +/- 3.0 years. The TLE procedural successes rate was 96.8% [1440/1505; 95% CI: (94.9-98.2%)] per patient and 96.3% [1447/1501; 95% CI: (94.8-97.4%)] per lead, and the clinical success rate per patient was 98.3% [989/1010, 95% CI: (97.4-99.0%)]. The procedure-related death rate was 0.08% [7/1729, 95% CI: (0.00%, 0.34%)], with major and minor complication rates of 1.9% [41/1729; 95% CI: (1.2-2.8%)] and 1.9% [58/1729; 95% CI: (0.8-3.6%)], respectively.Conclusion This meta-analysis demonstrated that excimer laser sheath-assisted TLE has high success and low procedural mortality rates. It provides clinicians with a reliable and valuable resource for extracting indwelling cardiac leads which require advanced extraction techniques.
引用
收藏
页数:8
相关论文
共 45 条
  • [1] The use of laser lead extraction sheath in the presence of supra-cardiac occlusion of the central veins for cardiac implantable electronic device lead upgrade or revision
    Al-Maisary, Sameer
    Romano, Gabriele
    Karck, Matthias
    De Simone, Raffaele
    Kremer, Jamila
    [J]. PLOS ONE, 2021, 16 (05):
  • [2] Almehmadi Fahad, 2018, Card Electrophysiol Clin, V10, P59, DOI 10.1016/j.ccep.2017.11.010
  • [3] Endovascular Occlusion Balloon for Treatment of Superior Vena Cava Tears During Transvenous Lead Extraction A Multiyear Analysis and an Update to Best Practice Protocol
    Azarrafiy, Ryan
    Tsang, Darren C.
    Wilkoff, Bruce L.
    Carrillo, Roger G.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (08)
  • [4] Transvenous Lead Extraction in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy
    Barakat, Amr F.
    Zmaili, Mohammad A.
    Tarakji, Khaldoun G.
    Shah, Shailee
    Rehman, Karim Abdur
    Martin, David O.
    Brunner, Michael P.
    Saliba, Walid, I
    Kanj, Mohamed
    Ballout, Jad
    Baranowski, Bryan
    Cantillon, Daniel
    Niebauer, Mark
    Callahan, Thomas
    Dresing, Thomas
    Rickard, John
    Lindsay, Bruce D.
    Wilkoff, Bruce L.
    Wazni, Oussama M.
    Hussein, Ayman A.
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (06) : 665 - 670
  • [5] Bashir Jamil, 2018, Card Electrophysiol Clin, V10, P651, DOI 10.1016/j.ccep.2018.08.003
  • [6] Bhatia M, 2017, SEMIN CARDIOTHORAC V, V21, P302, DOI 10.1177/1089253217728581
  • [7] 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS
    Bongiorni, Maria G.
    Burri, Haran
    Deharo, Jean C.
    Starck, Christoph
    Kennergren, Charles
    Saghy, Laszlo
    Rao, Archana
    Tascini, Carlo
    Lever, Nigel
    Kutarski, Andrzej
    Lozano, Ignacio Fernandez
    Strathmore, Neil
    Costa, Roberto
    Epstein, Laurence
    Love, Charles
    Blomstrom-Lundqvist, Carina
    Fauchier, Laurent
    Defaye, Pascal
    Arnar, David O.
    Klug, Didier
    Boveda, Serge
    Nielsen, Jens Cosedis
    Boriani, Giuseppe
    Zhang, Shu
    Martin, Andrew Paul
    Prutkin, Jordan M.
    de Zuloaga, Claudio
    [J]. EUROPACE, 2018, 20 (07): : 1217 - +
  • [8] The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes
    Bongiorni, Maria Grazia
    Kennergren, Charles
    Butter, Christian
    Deharo, Jean Claude
    Kutarski, Andrzej
    Rinaldi, Christopher A.
    Romano, Simone L.
    Maggioni, Aldo P.
    Andarala, Maryna
    Auricchio, Angelo
    Kuck, Karl-Heinz
    Blomstrom-Lundqvist, Carina
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 (40) : 2995 - 3005
  • [9] Overcoming the current issues surrounding device leads: reducing the complications during extraction
    Bongiorni, Maria Grazia
    Segreti, Luca
    Di Cori, Andrea
    Zucchelli, Giulio
    Paperini, Luca
    Viani, Stefano
    Soldati, Ezio
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (06) : 469 - 480
  • [10] Comparison between laser sheaths, femoral approach and rotating mechanical sheaths for lead extraction
    Bracke, F. A.
    Rademakers, N.
    Verberkmoes, N.
    Van 't Veer, M.
    van Gelder, B. M.
    [J]. NETHERLANDS HEART JOURNAL, 2022, 30 (05) : 267 - 272