Safe Optimal Tear Drop View for Spinopelvic Fixation Using a Three-Dimensional Reconstruction Model of the Pelvis

被引:2
作者
Park, Sung Cheol [1 ]
Hong, Tae Chang [2 ]
Yang, Jae Hyuk [1 ,5 ]
Chang, Dong-Gune [3 ,6 ]
Suh, Seung Woo [2 ]
Nam, Yunjin [2 ]
Kang, Min-Seok [1 ]
Jung, Tae-Gon [4 ]
Park, Kwang-Min [4 ]
Kang, Kwan-Su [4 ]
机构
[1] Korea Univ, Anam Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[2] Korea Univ, Coll Med, Dept Orthoped Surg, Guro Hosp, Seoul, South Korea
[3] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Orthoped Surg, Seoul, South Korea
[4] Osong Med Innovat Fdn, Med Device Dev Ctr, Cheongju, South Korea
[5] Korea Univ, Korea Univ, Dept Orthoped Surg, Anam Hosp,Coll Med, 73 Goryeodae Ro, Seoul 02841, South Korea
[6] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Orthoped Surg, 1342 Dongil ro, Seoul 01757, South Korea
关键词
Pelvis; Spinal fusion; Tear drop view; Spinopelvic fixation; Three-dimensional; ILIAC SCREWS; ACCURACY; PULLOUT; SPINE; ROD;
D O I
10.4055/cios22360
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Spinopelvic fixation (SPF) has been a challenge for surgeons despite the advancements in instruments and surgical techniques. C-arm fluoroscopy-guided SPF is a widely used safe technique that utilizes the tear drop view. The tear drop view is an image of the corridor from the posterior superior iliac spine to the anterior inferior iliac spine (AIIS) of the pelvis. This study aimed to define the safe optimal tear drop view using three-dimensional reconstruction of computed tomography images.Methods: Three-dimensional reconstructions of the pelvises of 20 individuals were carried out. By rotating the reconstructed model, we simulated SPF with a cylinder representing imaginary screw. The safe optimal tear drop view was defined as the one embracing a corridor with the largest diameter with the inferior tear drop line not below the acetabular line and the lateral tear drop line medial to the AIIS. The distance between the lateral border of the tear drop and AIIS was defined as tear drop index (TDI) to estimate the degree of rotation on the plane image. Tear drop ratio (TDR), the ratio of the distance between the tear drop center and the AIIS to TDI, was also devised for more intuitive application of our simulation in a real operation.Results: All the maximum diameters and lengths were greater than 9 mm and 80 mm, respectively, which are the values of gener-ally used screws for SPF at a TDI of 5 mm and 10 mm in both sexes. The TDRs were 3.40 +/- 0.41 and 3.35 +/- 0.26 in men and women, respectively, at a TDI of 5 mm. The TDRs were 2.26 +/- 0.17 and 2.14 +/- 0.12 in men and women, respectively, at a TDI of 10 mm.Conclusions: The safe optimal tear drop view can be obtained with a TDR of 2.5 to 3 by rounding off the measured values for in-tuitive application in the actual surgical field.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 50 条
  • [31] Three-Dimensional Reconstruction of Coronary Arteries and Plaque Morphology using CT Angiography - Comparison and Registration using IVUS
    Athanasiou, Lambros S.
    Rigas, George A.
    Sakellarios, Antonios I.
    Exarchos, Themis P.
    Siogkas, Panagiotis K.
    Michalis, Lampros K.
    Parodi, Oberdan
    Vozzi, Federico
    Fotiadis, Dimitrios I.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5638 - 5641
  • [32] Three-dimensional reconstruction of coronary arteries and plaque morphology using CT angiography - comparison and registration with IVUS
    Athanasiou, Lambros
    Rigas, George
    Sakellarios, Antonis I.
    Exarchos, Themis P.
    Siogkas, Panagiotis K.
    Bourantas, Christos V.
    Garcia-Garcia, Hector M.
    Lemos, Pedro A.
    Falcao, Breno A.
    Michalis, Lampros K.
    Parodi, Oberdan
    Vozzi, Federico
    Fotiadis, Dimitrios I.
    BMC MEDICAL IMAGING, 2016, 16
  • [33] Accuracy Evaluation of a Three-Dimensional Face Reconstruction Model Based on the Hifi3D Face Model and Clinical Two-Dimensional Images
    Xiao, Yujia
    Mao, Bochun
    Nie, Jianglong
    Liu, Jiayi
    Wang, Shuo
    Liu, Dawei
    Zhou, Yanheng
    BIOENGINEERING-BASEL, 2024, 11 (12):
  • [34] Posterior fixation and fusion of unstable Hangman's fracture by using intraoperative three-dimensional fluoroscopy-based navigation
    Tian, Wei
    Weng, Chong
    Liu, Bo
    Li, Qin
    Hu, Lin
    Li, Zhi-Yu
    Liu, Ya-Jun
    Sun, Yu-Zhen
    EUROPEAN SPINE JOURNAL, 2012, 21 (05) : 863 - 871
  • [35] Three-dimensional solid reconstruction of a human bone from CT images using interpolation with triangular Bezier patches
    Mun, Duhwan
    Kim, Byung Chul
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (08) : 3875 - 3886
  • [36] The Shape of Things to Come: In-Hospital Three-Dimensional Printing for Mandibular Reconstruction Using Fibula Free Flap
    Zavattero, Emanuele
    Fasolis, Massimo
    Novaresio, Andrea
    Gerbino, Giovanni
    Borbon, Claudia
    Ramieri, Guglielmo
    LARYNGOSCOPE, 2020, 130 (12) : E811 - E816
  • [37] Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
    Ki Young Lee
    Jung-Hee Lee
    Sang-Kyu Im
    Won Young Lee
    BMC Musculoskeletal Disorders, 23
  • [38] Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
    Lee, Ki Young
    Lee, Jung-Hee
    Im, Sang-Kyu
    Lee, Won Young
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [39] Three-dimensional evaluation of the holographic projection in digital dental model superimposition using HoloLens device
    Talaat, Sameh
    Ghoneima, Ahmed
    Kaboudan, Ahmed
    Talaat, Wael
    Ragy, Nivin
    Bourauel, Christoph
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 : 62 - 68
  • [40] Using three-dimensional CURVIC® contact models to predict stress concentration effects in an axisymmetric model
    Rencis, JJ
    Pisani, SR
    Boundary Elements XXVII: Incorporating Electrical Engineering and Electromagnetics, 2005, 39 : 245 - 254