Safe Optimal Tear Drop View for Spinopelvic Fixation Using a Three-Dimensional Reconstruction Model of the Pelvis

被引:2
作者
Park, Sung Cheol [1 ]
Hong, Tae Chang [2 ]
Yang, Jae Hyuk [1 ,5 ]
Chang, Dong-Gune [3 ,6 ]
Suh, Seung Woo [2 ]
Nam, Yunjin [2 ]
Kang, Min-Seok [1 ]
Jung, Tae-Gon [4 ]
Park, Kwang-Min [4 ]
Kang, Kwan-Su [4 ]
机构
[1] Korea Univ, Anam Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[2] Korea Univ, Coll Med, Dept Orthoped Surg, Guro Hosp, Seoul, South Korea
[3] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Orthoped Surg, Seoul, South Korea
[4] Osong Med Innovat Fdn, Med Device Dev Ctr, Cheongju, South Korea
[5] Korea Univ, Korea Univ, Dept Orthoped Surg, Anam Hosp,Coll Med, 73 Goryeodae Ro, Seoul 02841, South Korea
[6] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Orthoped Surg, 1342 Dongil ro, Seoul 01757, South Korea
关键词
Pelvis; Spinal fusion; Tear drop view; Spinopelvic fixation; Three-dimensional; ILIAC SCREWS; ACCURACY; PULLOUT; SPINE; ROD;
D O I
10.4055/cios22360
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Spinopelvic fixation (SPF) has been a challenge for surgeons despite the advancements in instruments and surgical techniques. C-arm fluoroscopy-guided SPF is a widely used safe technique that utilizes the tear drop view. The tear drop view is an image of the corridor from the posterior superior iliac spine to the anterior inferior iliac spine (AIIS) of the pelvis. This study aimed to define the safe optimal tear drop view using three-dimensional reconstruction of computed tomography images.Methods: Three-dimensional reconstructions of the pelvises of 20 individuals were carried out. By rotating the reconstructed model, we simulated SPF with a cylinder representing imaginary screw. The safe optimal tear drop view was defined as the one embracing a corridor with the largest diameter with the inferior tear drop line not below the acetabular line and the lateral tear drop line medial to the AIIS. The distance between the lateral border of the tear drop and AIIS was defined as tear drop index (TDI) to estimate the degree of rotation on the plane image. Tear drop ratio (TDR), the ratio of the distance between the tear drop center and the AIIS to TDI, was also devised for more intuitive application of our simulation in a real operation.Results: All the maximum diameters and lengths were greater than 9 mm and 80 mm, respectively, which are the values of gener-ally used screws for SPF at a TDI of 5 mm and 10 mm in both sexes. The TDRs were 3.40 +/- 0.41 and 3.35 +/- 0.26 in men and women, respectively, at a TDI of 5 mm. The TDRs were 2.26 +/- 0.17 and 2.14 +/- 0.12 in men and women, respectively, at a TDI of 10 mm.Conclusions: The safe optimal tear drop view can be obtained with a TDR of 2.5 to 3 by rounding off the measured values for in-tuitive application in the actual surgical field.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 50 条
  • [21] Image reconstruction of a three-dimensional dielectric object using a gradient-based optimization
    Harada, H
    Tanaka, M
    Takenaka, T
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2001, 29 (05) : 332 - 336
  • [22] Three-Dimensional Printed Model-Assisted Screw Installation in Treating Posterior Atlantoaxial Internal Fixation
    Yang, Minyi
    Zhang, Nannan
    Shi, Haodong
    Li, Hui
    Liu, Shichang
    Song, Zongrang
    Shan, Lequn
    Wu, Qining
    Hao, Dingjun
    SCIENTIFIC REPORTS, 2018, 8
  • [23] Ensemble squid habitat model using three-dimensional ocean data
    Alabia, Irene D.
    Saitoh, Sei-Ichi
    Igarashi, Hiromichi
    Ishikawa, Yoichi
    Usui, Norihisa
    Kamachi, Masafumi
    Awaji, Toshiyuki
    Seito, Masaki
    ICES JOURNAL OF MARINE SCIENCE, 2016, 73 (07) : 1863 - 1874
  • [24] Optimum design of reference points distribution in three-dimensional reconstruction of dental model in intercuspal position
    Yujia Wu
    Zhewen Hu
    Xinyue Zhang
    Hefei Bai
    Yuchun Sun
    Baolin Fan
    BMC Oral Health, 21
  • [25] Application of Virtual Planning for Three-Dimensional Guided Maxillofacial Reconstruction of Pruzansky-Kaban III Hemifacial Microsomia Using Custom Made Fixation Plate
    Liu, Kai
    Xu, Yuting
    Abdelrehem, Ahmed
    Jiang, Tengfei
    Wang, Xudong
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (03) : 896 - 901
  • [26] Three-dimensional laser ranging image reconstruction using three-line laser sensors and fuzzy methods
    Bursanescu, L
    Hamdi, M
    THREE-DIMENSIONAL IMAGING, OPTICAL METROLOGY, AND INSPECTION V, 1999, 3835 : 106 - 117
  • [27] Three-dimensional prediction of the nose for facial reconstruction using cone-beam computed tomography
    Lee, Kyung-Min
    Lee, Won-Joon
    Cho, Jin-Hyoung
    Hwang, Hyeon-Shik
    FORENSIC SCIENCE INTERNATIONAL, 2014, 236 : 194.e1 - 194.e5
  • [28] A low-cost three-dimensional reconstruction and monitoring system using digital fringe projection
    Ullah, Furqan
    Miran, Sajjad
    Ahmad, Furqan
    Ullah, Irfan
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2021, 45 (02) : 331 - 345
  • [29] Outcomes of mandibular reconstruction using three-dimensional custom-made porous titanium prostheses
    Haroun, Fabienne
    Benmoussa, Nadia
    Bidault, Francois
    Lassau, Nathalie
    Moya-Plana, Antoine
    Leymarie, Nicolas
    Honart, Jean-Francois
    Kolb, Frederic
    Qassemyar, Quentin
    Gorphe, Philippe
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [30] Three-Dimensional Reconstruction of Coronary Arteries and Plaque Morphology using CT Angiography - Comparison and Registration using IVUS
    Athanasiou, Lambros S.
    Rigas, George A.
    Sakellarios, Antonios I.
    Exarchos, Themis P.
    Siogkas, Panagiotis K.
    Michalis, Lampros K.
    Parodi, Oberdan
    Vozzi, Federico
    Fotiadis, Dimitrios I.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5638 - 5641