Safe Optimal Tear Drop View for Spinopelvic Fixation Using a Three-Dimensional Reconstruction Model of the Pelvis

被引:2
|
作者
Park, Sung Cheol [1 ]
Hong, Tae Chang [2 ]
Yang, Jae Hyuk [1 ,5 ]
Chang, Dong-Gune [3 ,6 ]
Suh, Seung Woo [2 ]
Nam, Yunjin [2 ]
Kang, Min-Seok [1 ]
Jung, Tae-Gon [4 ]
Park, Kwang-Min [4 ]
Kang, Kwan-Su [4 ]
机构
[1] Korea Univ, Anam Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[2] Korea Univ, Coll Med, Dept Orthoped Surg, Guro Hosp, Seoul, South Korea
[3] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Orthoped Surg, Seoul, South Korea
[4] Osong Med Innovat Fdn, Med Device Dev Ctr, Cheongju, South Korea
[5] Korea Univ, Korea Univ, Dept Orthoped Surg, Anam Hosp,Coll Med, 73 Goryeodae Ro, Seoul 02841, South Korea
[6] Inje Univ, Sanggye Paik Hosp, Coll Med, Dept Orthoped Surg, 1342 Dongil ro, Seoul 01757, South Korea
关键词
Pelvis; Spinal fusion; Tear drop view; Spinopelvic fixation; Three-dimensional; ILIAC SCREWS; ACCURACY; PULLOUT; SPINE; ROD;
D O I
10.4055/cios22360
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Spinopelvic fixation (SPF) has been a challenge for surgeons despite the advancements in instruments and surgical techniques. C-arm fluoroscopy-guided SPF is a widely used safe technique that utilizes the tear drop view. The tear drop view is an image of the corridor from the posterior superior iliac spine to the anterior inferior iliac spine (AIIS) of the pelvis. This study aimed to define the safe optimal tear drop view using three-dimensional reconstruction of computed tomography images.Methods: Three-dimensional reconstructions of the pelvises of 20 individuals were carried out. By rotating the reconstructed model, we simulated SPF with a cylinder representing imaginary screw. The safe optimal tear drop view was defined as the one embracing a corridor with the largest diameter with the inferior tear drop line not below the acetabular line and the lateral tear drop line medial to the AIIS. The distance between the lateral border of the tear drop and AIIS was defined as tear drop index (TDI) to estimate the degree of rotation on the plane image. Tear drop ratio (TDR), the ratio of the distance between the tear drop center and the AIIS to TDI, was also devised for more intuitive application of our simulation in a real operation.Results: All the maximum diameters and lengths were greater than 9 mm and 80 mm, respectively, which are the values of gener-ally used screws for SPF at a TDI of 5 mm and 10 mm in both sexes. The TDRs were 3.40 +/- 0.41 and 3.35 +/- 0.26 in men and women, respectively, at a TDI of 5 mm. The TDRs were 2.26 +/- 0.17 and 2.14 +/- 0.12 in men and women, respectively, at a TDI of 10 mm.Conclusions: The safe optimal tear drop view can be obtained with a TDR of 2.5 to 3 by rounding off the measured values for in-tuitive application in the actual surgical field.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 50 条
  • [1] Tumor resection at the pelvis using three-dimensional planning and patient-specific instruments: a case series
    Jentzsch, Thorsten
    Vlachopoulos, Lazaros
    Furnstahl, Philipp
    Mueller, Daniel A.
    Fuchs, Bruno
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2016, 14
  • [2] Application of navigation template to fixation of sacral fracture using three-dimensional reconstruction and reverse engineering technique
    Zhang Yuan-zhi
    Lu Sheng
    Xu Yong-qing
    Shi Ji-hong
    Li Yan-bing
    Feng Zi-liang
    CHINESE JOURNAL OF TRAUMATOLOGY, 2009, 12 (04) : 214 - 217
  • [3] Three-Dimensional Spine Model Reconstruction Using One-Class SVM Regularization
    Lecron, Fabian
    Boisvert, Jonathan
    Mahmoudi, Said
    Labelle, Hubert
    Benjelloun, Mohammed
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (11) : 3256 - 3264
  • [4] A new method for three-dimensional laparoscopic ultrasound model reconstruction
    C. W. Fristrup
    T. Pless
    J. Durup
    M. B. Mortensen
    H. O. Nielsen
    C. P. Hovendal
    Surgical Endoscopy And Other Interventional Techniques, 2004, 18 : 1601 - 1604
  • [5] A new method for three-dimensional laparoscopic ultrasound model reconstruction
    Fristrup, CW
    Pless, T
    Durup, J
    Mortensen, MB
    Nielsen, HO
    Hovendal, CP
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2004, 18 (11): : 1601 - 1604
  • [6] Three-dimensional anatomy of the pelvis in bladder exstrophy: Description of bone pathology by using three-dimensional computed tomography and its clinical relevance
    Yazici, M
    Sozubir, S
    Kilicoglu, G
    Bernay, F
    Incesu, L
    Ariturk, E
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1998, 18 (01) : 132 - 135
  • [7] A new method for three-dimensional laparoscopic ultrasound model reconstruction
    C. W. Fristrup
    T. Pless
    J. Durup
    M. B. Mortensen
    H. O. Nielsen
    C. P. Hovendal
    Surgical Endoscopy And Other Interventional Techniques, 2004, 18 : 1601 - 1604
  • [8] Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility
    Hoevenaren, Inge A.
    Meulstee, J.
    Krikken, E.
    Berge, S. J.
    Ulrich, D. J. O.
    Maal, Thomas J. J.
    PLOS ONE, 2015, 10 (09):
  • [9] Optimum design of reference points distribution in three-dimensional reconstruction of dental model in intercuspal position
    Wu, Yujia
    Hu, Zhewen
    Zhang, Xinyue
    Bai, Hefei
    Sun, Yuchun
    Fan, Baolin
    BMC ORAL HEALTH, 2021, 21 (01)
  • [10] A new reconstruction of Sts 14 pelvis (Australopithecus africanus) from computed tomography and three-dimensional modeling techniques
    Berge, Christine
    Goularas, Dionysis
    JOURNAL OF HUMAN EVOLUTION, 2010, 58 (03) : 262 - 272