Study on surface hydrogenated Ti6Al4V alloy for orthopedic implants

被引:4
作者
Lin, Yu-Chien [1 ,2 ,6 ,9 ]
Hu, Chih-Chien [1 ,3 ,4 ,5 ,6 ,9 ]
Nguyen, Thu-Trang [1 ,6 ,9 ]
Dhawan, Udesh [1 ,9 ]
Chou, Ching-Yi [1 ,6 ,9 ]
Lee, Yueh-Lien [1 ,6 ,9 ]
Yen, Hung-Wei [1 ,6 ,8 ,9 ]
Kuo, Yi-Jie [1 ,6 ,7 ,9 ]
Chung, Ren-Jei [1 ,6 ,9 ,10 ,11 ,12 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei, Taiwan
[2] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore City, Singapore
[3] Chang Gung Mem Hosp, Bone & Joint Res Ctr, Linkou, Taiwan
[4] Chang Gung Mem Hosp, Dept Orthopaed Surg, Linkou, Taiwan
[5] Chang Gung Univ, Coll Med, Taoyuan, Taiwan
[6] Univ Glasgow, Ctr Cellular Microenvironm, Mazumdar Shaw Adv Res Ctr, James Watt Sch Engn,Div Biomed Engn, Glasgow, Scotland
[7] Natl Taiwan Univ, Dept Engn Sci & Ocean Engn, Taipei, Taiwan
[8] Natl Taiwan Univ, Dept Mat Sci & Engn, Taipei, Taiwan
[9] Taipei Med Univ, Wan Fang Hosp, Dept Orthoped Surg, Taipei, Taiwan
[10] Taipei Med Univ, Coll Med, Sch Med, Dept Orthoped Surg, Taipei, Taiwan
[11] Natl Taipei Univ Technol Taipei Tech, High value Biomat Res & Commercializat Ctr, Taipei 10608, Taiwan
[12] Natl Taipei Univ Technol Taipei Tech, Dept Chem Engn & Biotechnol, 1 Sec 3,Zhongxiao E Rd, Taipei 10608, Taiwan
来源
JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T | 2024年 / 28卷
关键词
Handling editor: PYChen; Orthopedic implants; Ti6Al4V alloys; Electrochemical hydrogen storage; Hydrogen therapy; Oxidative stress; MECHANICAL-PROPERTIES; REACTIVE-OXYGEN; TITANIUM-ALLOYS; TI-6AL-4V; CELLS; ROS;
D O I
10.1016/j.jmrt.2023.12.066
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Titanium-based alloys exhibit superior resistance to corrosion and biocompatibility in comparison to other alloys utilized for implant applications, such as stainless steel and cobalt-based alloys. Nonetheless, no completely inert metal is suitable for implantation in the human body, as aseptic loosening of the implant or the release of ions in the vicinity of the implant can result in inflammation and implant failure. Therefore, the primary objective of this study was to employ hydrogenated titanium 6-aluminum-4-vanadium (H-Ti6Al4V) alloy to reduce reactive oxygen species (ROS) and thereby achieve the function of regulating inflammatory signaling when employed as an implant.The Ti6Al4V alloy was successfully hydrogenated using a cathodic hydrogen-charging method. The H-Ti6Al4V alloy displayed a surface Young's modulus 33.97 +/- 9.21 GPa similar to that of trabecular bone (similar to 22.3 GPa) and notably lower hardness (3.32 +/- 0.62 GPa) than the Ti6Al4V alloy (21.79 +/- 2.42 GPa). In vitro and in vivo investigations indicated that the H-Ti6Al4V alloy did not negatively affect bone-related cells and triggered minimal inflammatory responses in Sprague-Dawley rats. Moreover, reduced ROS production was observed around the H-Ti6Al4V alloys, confirming that hydrogenation could effectively counteract the ROS generated during cell metabolism and indirectly impede the inflammatory response around the prosthesis, thereby rendering it a promising metallic implant for the treatment of bone defects.
引用
收藏
页码:1504 / 1513
页数:10
相关论文
共 50 条
  • [1] Microstructure evolution of hydrogenated Ti6Al4V alloy during cornpression
    Yuan, Baoguo
    Chen, Qiang
    Yu, Haiping
    Li, Ping
    Xue, Kemin
    Li, Chunfeng
    DIGITAL MANUFACTURING & AUTOMATION III, PTS 1 AND 2, 2012, 190-191 : 517 - +
  • [2] Wear properties of nonhydrogenated, hydrogenated, and dehydrogenated Ti6Al4V alloy
    Yuan, Bao-Guo
    Yu, Hai-Ping
    Li, Chun-Feng
    Sun, Dong-Li
    RARE METALS, 2018, 37 (07) : 574 - 578
  • [3] Evaluation of physicochemical properties of surface modified Ti6Al4V and Ti6Al7Nb alloys used for orthopedic implants
    Basiaga, Marcin
    Kajzer, Wojciech
    Walke, Witold
    Kajzer, Anita
    Kaczmarek, Marcin
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 68 : 851 - 860
  • [4] Investigation on high temperature compression behaviour of hydrogenated Ti6Al4V alloy
    Cheng, X. L.
    Zhang, H.
    Bai, B. Z.
    Fu, H. G.
    Guo, L.
    MATERIALS SCIENCE AND TECHNOLOGY, 2011, 27 (10) : 1547 - 1550
  • [5] Surface Modifications to the Ti6Al4V Alloy for Improvement as Biomaterial
    Flores-Alvarez, J. F.
    Rodriguez-Gomez, F. J.
    Onofre-Bustamante, E.
    XXXII NATIONAL CONGRESS OF THE MEXICAN SOCIETY OF ELECTROCHEMISTRY/10TH MEETING OF THE ECS MEXICAN SECTION, 2018, 84 (01): : 15 - 27
  • [6] Enhancing the biocompatibility of Ti6Al4V implants by laser surface microtexturing: an in vitro study
    Mukherjee, S.
    Dhara, S.
    Saha, P.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2015, 76 (1-4) : 5 - 15
  • [7] Abrasive machining of Ti6Al4V alloy
    Lattner, Radek
    Holešovskỳ, František
    Karel, Tomáš
    Lattner, Michal
    Manufacturing Technology, 2015, 15 (04): : 571 - 575
  • [8] Cryogenic turning of Ti6Al4V alloy
    Sola, R.
    Veronesi, P.
    METALLURGIA ITALIANA, 2020, 112 (7-8): : 28 - 36
  • [9] Oxidation behaviour of plasma surface alloying on Ti6Al4V alloy
    Wei, D. -B.
    Zhang, P. -Z.
    Yao, Z. -J.
    Wei, X. -F.
    Zhou, J. -T.
    Chen, X. -H.
    SURFACE ENGINEERING, 2018, 34 (01) : 14 - 21
  • [10] Numerical simulation and experimental investigation of laser joining Ti6Al4V alloy and CFRTP with embedded Ti6Al4V alloy
    Xu, Ying
    Bu, Hengchang
    Wang, Feiyun
    Ma, Wanping
    Zhan, Xiaohong
    OPTICS AND LASER TECHNOLOGY, 2022, 156