Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI

被引:1
|
作者
Kummari, Satyanarayana [1 ]
Burra, Kiran Goud [2 ]
Reddy, Vudem Ranjith Kumar [3 ]
Das, Saraswata [4 ]
Anilkumar, Challa [1 ]
机构
[1] Great Eastern Med Sch & Hosp, Dept Radiol, Srikakulam, India
[2] Govt Dist Hosp, Dept Radiol, Medak, India
[3] Surabhi Inst Med Sci, Dept Radiol, Siddipet, India
[4] Coll Med & JNM Hosp, Dept Radiodiag, Kalyani, India
关键词
3-tesla mri; cnr; snr; comparison; mri; 3d-flair; 2d-flair; multiple sclerosis; FAST SPIN-ECHO; DIAGNOSTIC-CRITERIA; PULSE SEQUENCES; LESION LOAD; BRAIN; QUANTIFICATION; ARTIFACTS;
D O I
10.7759/cureus.48136
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A fluid-attenuated inversion recovery (FLAIR) method eliminates the cerebrospinal fluid (CSF) signal, enhancing white matter lesion detection by enhancing the contrast between the lesion and CSF. Three-dimensional (3D) volume acquisition has the advantage of multiplanar reformation of contiguous slices yielding improved signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs). To our knowledge, there are only three studies comparing 3D-and 2D-FLAIR sequences with respect to multiple sclerosis (MS) lesions at 3 tesla.Aims and objectives: This study aimed to determine the efficiency of 3D-FLAIR in the detection of lesions of multiple sclerosis in terms of spatial and contrast resolutions in comparison with 2D-FLAIR sequences.Methodology: A total of 75 patients with MS undergoing magnetic resonance imaging (MRI) brain at the Department of Radiology, Krishna Institute of Medical Sciences (KIMS), Secunderabad, Telangana, India. This is an observational comparative study. Independent-samples t-tests were performed in the present study to compare the number of lesions detected. The measured CNR and SNR values were subjected to Mann-Whitney U test.Results: As a result of the 3D-FLAIR, more lesions were found as compared to 2D-FLAIR (p = 0.001). There was a greater CNRs for 3D-FLAIR images than for 2D-FLAIR images (p = 0.001). Lesions, CSF, white matter, and gray matter showed significantly higher SNRs with 3D-FLAIR (p = 0.001).Conclusion: 3D-FLAIR has exhibited greater sensitivity in detecting lesions associated with MS when contrasted with the 2D-FLAIR sequence. Significantly more lesions and higher SNRs and CNRs were detected with 3D-FLAIR in contrast to 2D-FLAIR. 3D-FLAIR may be considered the sequence of choice for MS imaging in the future.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Highly Sensitive 3-Tesla Real Inversion Recovery MRI Detects Leptomeningeal Contrast Enhancement in Chronic Active Multiple Sclerosis
    Okar, Serhat Vahip
    Dieckhaus, Henry
    Beck, Erin S.
    Gaitan, Maria I.
    Norato, Gina
    Pham, Dzung L.
    Absinta, Martina
    Cortese, Irene C. M.
    Fletcher, Anita
    Jacobson, Steven
    Nair, Govind
    Reich, Daniel S.
    INVESTIGATIVE RADIOLOGY, 2024, 59 (03) : 243 - 251
  • [42] Unmasking the Area Postrema on MRI: Utility of 3D FLAIR, 3D-T2, and 3D-DIR Sequences in a Case-Control Study
    Lara-Garcia, Javier
    Romo-Martinez, Jessica
    De-La-Cruz-Cisneros, Jonathan Javier
    Olvera-Olvera, Marco Antonio
    Marquez-Bejarano, Luis Jesus
    JOURNAL OF IMAGING, 2025, 11 (01)
  • [43] Visualization of wrist ligaments with 3D and 2D magnetic resonance imaging at 3 Tesla
    Gotestrand, Simon
    Bjorkman, Anders
    Bjorkman-Burtscher, Isabella M.
    Ab-Fawaz, Rana
    Kristiansson, Ingvar
    Lundin, Bjorn
    Geijer, Mats
    ACTA RADIOLOGICA, 2022, 63 (03) : 368 - 375
  • [44] Multicontrast MR Imaging at 7T in Multiple Sclerosis: Highest Lesion Detection in Cortical Gray Matter with 3D-FLAIR
    Kilsdonk, I. D.
    de Graaf, W. L.
    Soriano, A. Lopez
    Zwanenburg, J. J.
    Visser, F.
    Kuijer, J. P. A.
    Geurts, J. J. G.
    Pouwels, P. J. W.
    Polman, C. H.
    Castelijns, J. A.
    Luijten, P. R.
    Barkhof, F.
    Wattjes, M. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (04) : 791 - 796
  • [45] 3D-Double-Inversion Recovery detects perilesional gliosis better than 3D-FLAIR and postcontrast T1 imaging in calcified neurocysticercosis
    Saini, Jitender
    Gupta, Pradeep Kumar
    Gupta, Praveen
    Yadav, Ravi
    Yadav, Nishtha
    Gupta, Rakesh Kumar
    NEUROLOGY INDIA, 2019, 67 (01) : 136 - 141
  • [46] Clinical evaluation of white matter lesions on 3D inversion recovery ultrashort echo time MRI in multiple sclerosis
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Afsahi, Amir Masoud
    Reichardt, Benjamin
    Corey-Bloom, Jody
    Du, Jiang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4171 - 4180
  • [47] Intravenous enhanced 3D FLAIR imaging to identify CSF leaks in spontaneous intracranial hypotension: Comparison with MR myelography
    Osawa, Iichiro
    Kozawa, Eito
    Mitsufuji, Takashi
    Yamamoto, Toshimasa
    Araki, Nobuo
    Inoue, Kaiji
    Niitsu, Mamoru
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [48] The clinical feasibility of artificial intelligence-assisted compressed sensing single-shot fluid-attenuated inversion recovery (ACS-SS-FLAIR) for evaluation of uncooperative patients with brain diseases: comparison with the conventional T2-FLAIR with parallel imaging
    Liu, Kai
    Xi, Bin
    Sun, Haitao
    Wang, Jian
    Chen, Caizhong
    Wen, Xixi
    Zhang, Yunfei
    Zeng, Mengsu
    ACTA RADIOLOGICA, 2023, 64 (05) : 1943 - 1949
  • [49] Signal intensity change of the labyrinth in patients with surgically confirmed or radiologically diagnosed vestibular schwannoma on isotropic 3D fluid-attenuated inversion recovery MR imaging at 3 T
    Lee, In Ho
    Kim, Hyung-Jin
    Chung, Won Ho
    Kim, Eunhee
    Moon, Jung Won
    Kim, Sung Tae
    Kim, Keon Ha
    Jeon, Pyoung
    Byun, Hong Sik
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 949 - 957
  • [50] Can Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch (Positive Diffusion-Weighted Imaging/Negative Fluid-Attenuated Inversion Recovery) at 3 Tesla Identify Patients With Stroke at <4.5 Hours?
    Emeriau, Samuel
    Serre, Isabelle
    Toubas, Olivier
    Pombourcq, Francis
    Oppenheim, Catherine
    Pierot, Laurent
    STROKE, 2013, 44 (06) : 1647 - 1651