Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI

被引:3
作者
Kummari, Satyanarayana [1 ]
Burra, Kiran Goud [2 ]
Reddy, Vudem Ranjith Kumar [3 ]
Das, Saraswata [4 ]
Anilkumar, Challa [1 ]
机构
[1] Great Eastern Med Sch & Hosp, Dept Radiol, Srikakulam, India
[2] Govt Dist Hosp, Dept Radiol, Medak, India
[3] Surabhi Inst Med Sci, Dept Radiol, Siddipet, India
[4] Coll Med & JNM Hosp, Dept Radiodiag, Kalyani, India
关键词
3-tesla mri; cnr; snr; comparison; mri; 3d-flair; 2d-flair; multiple sclerosis; FAST SPIN-ECHO; DIAGNOSTIC-CRITERIA; PULSE SEQUENCES; LESION LOAD; BRAIN; QUANTIFICATION; ARTIFACTS;
D O I
10.7759/cureus.48136
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A fluid-attenuated inversion recovery (FLAIR) method eliminates the cerebrospinal fluid (CSF) signal, enhancing white matter lesion detection by enhancing the contrast between the lesion and CSF. Three-dimensional (3D) volume acquisition has the advantage of multiplanar reformation of contiguous slices yielding improved signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs). To our knowledge, there are only three studies comparing 3D-and 2D-FLAIR sequences with respect to multiple sclerosis (MS) lesions at 3 tesla.Aims and objectives: This study aimed to determine the efficiency of 3D-FLAIR in the detection of lesions of multiple sclerosis in terms of spatial and contrast resolutions in comparison with 2D-FLAIR sequences.Methodology: A total of 75 patients with MS undergoing magnetic resonance imaging (MRI) brain at the Department of Radiology, Krishna Institute of Medical Sciences (KIMS), Secunderabad, Telangana, India. This is an observational comparative study. Independent-samples t-tests were performed in the present study to compare the number of lesions detected. The measured CNR and SNR values were subjected to Mann-Whitney U test.Results: As a result of the 3D-FLAIR, more lesions were found as compared to 2D-FLAIR (p = 0.001). There was a greater CNRs for 3D-FLAIR images than for 2D-FLAIR images (p = 0.001). Lesions, CSF, white matter, and gray matter showed significantly higher SNRs with 3D-FLAIR (p = 0.001).Conclusion: 3D-FLAIR has exhibited greater sensitivity in detecting lesions associated with MS when contrasted with the 2D-FLAIR sequence. Significantly more lesions and higher SNRs and CNRs were detected with 3D-FLAIR in contrast to 2D-FLAIR. 3D-FLAIR may be considered the sequence of choice for MS imaging in the future.
引用
收藏
页数:12
相关论文
共 25 条
[1]   3D fast FLAIR: A CSF-nulled 3D fast spin-echo pulse sequence [J].
Barker, GJB .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :715-720
[2]  
Bastianello S, 1997, AM J NEURORADIOL, V18, P699
[3]   Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results [J].
Bink, A ;
Schmitt, M ;
Gaa, J ;
Mugler, JP ;
Lanfermann, H ;
Zanella, FE .
EUROPEAN RADIOLOGY, 2006, 16 (05) :1104-1110
[4]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[5]  
DECOENE B, 1992, AM J NEURORADIOL, V13, P1555
[6]   Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery [J].
Filippi, M ;
Yousry, T ;
Baratti, C ;
Horsfield, MA ;
Mammi, S ;
Becker, C ;
Voltz, R ;
Spuler, S ;
Campi, A ;
Reiser, MF ;
Comi, G .
BRAIN, 1996, 119 :1349-1355
[7]   USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844
[8]   Accuracy for detection of simulated lesions: Comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging [J].
Herskovits, EH ;
Itoh, R ;
Melhem, ER .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1313-1318
[9]   Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: Initial experience [J].
Kallmes, DF ;
Hui, FK ;
Mugler, JP .
RADIOLOGY, 2001, 221 (01) :251-255
[10]   3D Fluid-Attenuated Inversion Recovery Imaging: Reduced CSF Artifacts and Enhanced Sensitivity and Specificity for Subarachnoid Hemorrhage [J].
Lummel, N. ;
Schoepf, V. ;
Burke, M. ;
Brueckmann, H. ;
Linn, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) :2054-2060