Universal cervical length screening for preterm birth is not useful after 24?weeks of gestation

被引:0
|
作者
Seravalli, Viola [1 ,3 ]
Abati, Isabella [1 ]
Strambi, Noemi [1 ]
Tofani, Lorenzo [2 ]
Tucci, Claudia [1 ]
Tartarotti, Enrico [1 ]
Di Tommaso, Mariarosaria [1 ]
机构
[1] Univ Florence, Careggi Hosp, Dept Hlth Sci, Div Obstet & Gynecol, Florence, Italy
[2] Univ Florence, Dept Stat, Comp Sci, Applicat, Florence, Italy
[3] Univ Florence, Dept Hlth Sci, Largo Brambilla 3, Florence, Italy
关键词
cervical length; pregnancy; preterm birth; preterm delivery; PREDICTION; RISK;
D O I
10.1111/aogs.14683
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction: Cervical length measurement using transvaginal sonography at 18(+0)-24(+0) weeks of gestation is used to identify women at risk of preterm delivery, who may benefit from treatment with progesterone to prevent premature birth. Few and conflicting data exist regarding the predictive value of cervical length measurement performed at later gestational ages. The primary objective of this study was to evaluate the predictive accuracy for spontaneous preterm birth of a single cervical length measurement performed between 24 and 32 weeks of gestation in asymptomatic singleton pregnancies at low risk for spontaneous preterm birth. The secondary objective was to test the predictive accuracy of different cervical length thresholds in the same population.Material and methods: This was a historical cohort study conducted in a tertiary referral hospital. A total of 2728 asymptomatic women with singleton pregnancy at low risk for spontaneous preterm birth were recruited. Of these women, 1548 had cervical length measured at 24(+0)-27(+6) weeks of gestation and 2191 women at 28(+0)-32(+0) weeks. In all, 1010 women were present in both gestational age windows. Maternal demographics, medical and obstetrical history, and pregnancy outcome were reviewed. The predictive value of cervical length for spontaneous preterm birth was evaluated through logistic regression analysis. Results were adjusted for confounding factors.Results: Overall, spontaneous preterm birth occurred in 53/2728 women (1.9%). In both the 24(+0)-27(+6) and 28(+0)-32(+0) weeks groups, a shorter cervical length was significantly associated with spontaneous preterm birth (p < 0.01), but it had a low predictive value, as shown by the receiver operating characteristics curve analysis (areas under the curve 0.62, 95% CI 0.50-0.74 for the 24(+0)-27(+6) weeks group, and 0.61, 95% CI 0.52-0.70 in the 28(+0)-32(+0) weeks group). When the predictive accuracy for preterm delivery of different cervical length cut-offs was evaluated, the sensitivity and positive predictive value were low in both gestational age windows, irrespective of the threshold used.Conclusions: In asymptomatic women with singleton pregnancy at low risk for spontaneous preterm birth, the predictive value of cervical length after 24(+0) weeks of gestation is low. Therefore, cervical length screening in these women should be discouraged.
引用
收藏
页码:1541 / 1548
页数:8
相关论文
共 50 条
  • [1] Is Cervical Length Screening Beyond 24 Weeks Gestation Cost-Effective in Women with a Prior Preterm Birth?
    Sharshiner, Rita
    Page, Jessica
    Caughey, Aaron B.
    REPRODUCTIVE SCIENCES, 2016, 23 : 280A - 280A
  • [2] Cervical length screening after 24 weeks for prediction and prevention of preterm birth: not evidence based yet ...
    Berghella, Vincenzo
    Lesser, Tal
    Boelig, Rupsa C.
    Roman, Amanda
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2020, 2 (02)
  • [3] Cervical Length Surveillance After 24 Weeks in Women With a History of Spontaneous Preterm Birth
    Jones, Eboni
    Whitley, Kari
    Quinones, Joanne
    Durie, Danielle
    Fradeneck, Katherine
    OBSTETRICS AND GYNECOLOGY, 2020, 135 : 116S - 116S
  • [4] Cervical Length at 28-32 Weeks of Gestation Predicts Preterm Birth
    Zhang, Mengying
    Zhang, Xiaoxiao
    Yang, Huixia
    Shi, Chunyan
    MATERNAL-FETAL MEDICINE, 2021, 3 (03) : 185 - 189
  • [5] Cervical Length at 28-32 Weeks of Gestation Predicts Preterm Birth
    Zhang Mengying
    Zhang Xiaoxiao
    Yang Huixia
    Shi Chunyan
    母胎医学杂志(英文), 2021, 03 (03) : 185 - 189
  • [7] Universal cervical length screening with a cervicometer to prevent preterm birth <34 weeks: a decision and economic analysis
    McCurdy, Rebekah J.
    Baxter, Jason K.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (21): : 3670 - 3679
  • [8] Universal cervical length screening for preterm birth prevention: implementation and outcomes
    Temming, Lorene A.
    Durst, Jennifer K.
    Stout, Molly J.
    Tuuli, Methodius G.
    Macones, George A.
    Cahill, Alison G.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S11 - S11
  • [9] Implementation of a Universal Cervical Length Screening Program for the Prevention of Preterm Birth
    Orzechowski, Kelly M.
    Nicholas, Sara S.
    Baxter, Jason K.
    Weiner, Stuart
    Berghella, Vincenzo
    AMERICAN JOURNAL OF PERINATOLOGY, 2014, 31 (12) : 1057 - 1062
  • [10] A Universal Transvaginal Cervical Length Screening Program for Preterm Birth Prevention
    Orzechowski, Kelly M.
    Boelig, Rupsa C.
    Baxter, Jason K.
    Berghella, Vincenzo
    OBSTETRICS AND GYNECOLOGY, 2014, 124 (03): : 520 - 525