Space vector-based model predictive current controller for grid-connected converter under unbalanced and distorted grid without a phase-locked loop

被引:4
作者
El -Nagar, Mohammed [1 ]
Elattar, Omar [1 ]
Ahmed, Khaled [2 ]
Hamdan, Eman [3 ]
Abdel-Khalik, Ayman S. [1 ]
Hamad, Mostafa S. [4 ]
Ahmed, Shehab [5 ]
机构
[1] Alexandria Univ, Fac Engn, Elect Engn Dept, Alexandria, Egypt
[2] Univ Strathclyde, Dept Elect & Elect Engn, Glasgow G1 1XQ, Scotland
[3] Arab Acad Sci Technol & Maritime Transport, Marine Engn Technol Dept, 1029, Alexandria, Egypt
[4] Arab Acad Sci Technol & Maritime Transport, Res & Dev Ctr, Al Alamein 5060305, Egypt
[5] King Abdullah Univ Sci & Technol, CEMSE Div, Thuwal, Saudi Arabia
关键词
Distorted grid; Harmonic mitigation; Power quality; Extended complex Kalman filter; Phase locked loop problems; Model predictive current controller; Space vector pulse width modulation; Voltage source converter; FREQUENCY ESTIMATION; POWER-CONTROL; DFIG; INVERTER; SYSTEM; PARAMETERS; OBSERVER; FILTERS;
D O I
10.1016/j.aej.2023.06.092
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents an improved current control strategy for a three-phase voltage source converter connected to distorted grid. The proposed controller can successfully compensate the induced harmonic currents, while suppressing possible active power ripple. To manage various objectives and deal with tough restrictions, model predictive control can offer a promising solution. However, a modified extended complex Kalman filter is introduced to estimate the positive and negative fundamental components of the grid voltages which are used with the real and reactive power references to generate pure sinusoidal reference currents without the need for a phase-locked loop (PLL), avoiding its challenges under abnormal grid conditions. An improved space vector-based model predictive control (SVM-MPC) is proposed to regulate the real and reactive power components. The main target of this controller is to maintain harmonic free grid currents, even in unbalanced and distorted grid conditions, with enhanced performance in terms of fast dynamic response and good steady-state behavior. The proposed SVM MPC uses Pythagoras theorem to determine duty factors, avoiding trigonometric functions, which improves the computational burden and implementation complexity. In addition, fixed switching frequency can be ensured. Simulation
引用
收藏
页码:265 / 281
页数:17
相关论文
共 53 条
[1]   Postfault Control of Scalar (V/f) Controlled Asymmetrical Six-Phase Induction Machines [J].
Abdel-Khalik, Ayman S. ;
Hamdy, Ragi A. ;
Massoud, Ahmed M. ;
Ahmed, Shehab .
IEEE ACCESS, 2018, 6 :59211-59220
[2]  
Ahmed K., 2011, 2011 INT C POWER ENG, P1
[3]   Autonomous adaptive sensorless controller of inverter-based islanded-distributed generation system [J].
Ahmed, K. H. ;
Massoud, A. M. ;
Finney, S. J. ;
Williams, B. W. .
IET POWER ELECTRONICS, 2009, 2 (03) :256-266
[4]   Current Control of a Three-Phase, Grid-Connected Inverter in the Presence of Unknown Grid Parameters Without a Phase-Locked Loop [J].
Alqatamin, Moath ;
Latham, Joseph ;
Smith, Zachary T. ;
Grainger, Brandon M. ;
McIntyre, Michael L. .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (03) :3127-3136
[5]   A New Model Predictive Current Controller for Grid-Connected Converters in Unbalanced Grids [J].
Andrew, Euan T. ;
Ahmed, Khaled H. ;
Holliday, Derrick .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) :9175-9186
[6]  
[Anonymous], 2014, IEEE STD 519 2014 RE, P1
[7]   Low-Complexity Model Predictive Stator Current Control of DFIG Under Harmonic Grid Voltages [J].
Cheng, Chenwen ;
Nian, Heng .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (03) :1072-1080
[8]   Performance Improvement of a Grid-Connected Inverter under Distorted Grid Voltage Using a Harmonic Extractor [J].
Cho, Sungjoon ;
Kang, Ho-Sung ;
Lee, Kyo-Beum ;
Yoo, Ji-Yoon .
ELECTRONICS, 2019, 8 (09)
[9]   An extended complex Kalman filter for frequency measurement of distorted signals [J].
Dash, PK ;
Jena, RK ;
Panda, G ;
Routray, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) :746-753
[10]   Frequency estimation of distorted power system signals using extended complex Kalman filters [J].
Dash, PK ;
Pradhan, AK ;
Panda, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) :761-766