Computed Tomography; Fabricated Ge-doped silica Fiber; LS-2000; Radioluminescence; Real-time optical fiber dosimetry; GE;
D O I
10.1016/j.radphyschem.2023.110972
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accel-erating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
[21]   The use of portable intraoperative computed tomography scanning for real-time image guidance: A pilot cadaver study [J].
Das, Subinoy ;
Maeso, Patricia A. ;
Figueroa, Ramon E. ;
Senior, Brent A. ;
Delgaudio, John M. ;
Sillers, Michael J. ;
Schlosser, Rod J. ;
Kountakis, Stilianos E. .
AMERICAN JOURNAL OF RHINOLOGY, 2008, 22 (02) :166-169
[22]   Real-Time Ultrasound-Computed Tomography Fusion with Volume Navigation to Assess Pancreatic Cystic Lesions [J].
Mathew, Manoj ;
Virarkar, Mayur ;
Sun, Jia ;
Thai, Khoan ;
Saleh, Mohammed ;
Menendez-Santos, Manuel ;
Bedi, Deepak ;
Lee, Jeffrey E. ;
Katz, Matthew ;
Kundra, Vikas ;
Bhosale, Priya .
CURRENT ONCOLOGY, 2023, 30 (09) :8375-8385
[23]   Real-time ultrasound-computed tomography image fusion for transforaminal lumbar approach: a lumbosacral spine phantoms study [J].
Guntz Emmanuel ;
Pourveur Arnaud ;
Gouwy Jonathan ;
Renard Marie ;
Mocanu Iulia ;
Pather Sanjiva ;
Fils Jean-François ;
Vannieuwenhove Olivier .
European Spine Journal, 2021, 30 :1270-1276
[24]   Real-time ultrasound-computed tomography image fusion for transforaminal lumbar approach: a lumbosacral spine phantoms study [J].
Emmanuel, Guntz ;
Arnaud, Pourveur ;
Jonathan, Gouwy ;
Marie, Renard ;
Iulia, Mocanu ;
Sanjiva, Pather ;
Jean-Francois, Fils ;
Olivier, Vannieuwenhove .
EUROPEAN SPINE JOURNAL, 2021, 30 (05) :1270-1276
[25]   IMAGE FUSION OF REAL-TIME ULTRASONOGRAPHY WITH COMPUTED TOMOGRAPHY: FACTORS AFFECTING THE REGISTRATION ERROR AND MOTION OF FOCAL HEPATIC LESIONS [J].
Lee, Min Woo ;
Park, Hyun Jeong ;
Kang, Tae Wook ;
Ryu, Jiwon ;
Bang, Won-Chul ;
Lee, Bora ;
Lee, Eun Sun ;
Choi, Byung Ihn .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (09) :2024-2032
[26]   Dynamic X-Ray Diffraction Computed Tomography Reveals Real-Time Insight into Catalyst Active Phase Evolution [J].
Jacques, Simon D. M. ;
Di Michiel, Marco ;
Beale, Andrew M. ;
Sochi, Taha ;
O'Brien, Matthew G. ;
Espinosa-Alonso, Leticia ;
Weckhuysen, Bert M. ;
Barnes, Paul .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (43) :10148-10152
[27]   A competitive radioluminescence material - LiF:Mg,Cu,P for real-time dosimetry [J].
Zhang, Siyuan ;
Tang, Kaiyong ;
Fan, Haijun ;
Fu, Li .
RADIATION MEASUREMENTS, 2022, 151
[28]   Ge-doped silica optical fibre for Time Resolved Radiation Dosimetry [J].
Basaif, A. ;
Oresegun, Adebiyi ;
Tarif, Zubair H. ;
Zin, Hafiz ;
Choo, K. Y. ;
Ibrahim, S. A. ;
Abdul-Rashid, H. A. ;
Bradley, D. A. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 189
[29]   Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study [J].
Matsubara, Kosuke ;
Kawashima, Hiroki ;
Kobayashi, Masanao ;
Fukuda, Atsushi .
HEALTH AND TECHNOLOGY, 2020, 10 (06) :1437-1443
[30]   Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study [J].
Kosuke Matsubara ;
Hiroki Kawashima ;
Masanao Kobayashi ;
Atsushi Fukuda .
Health and Technology, 2020, 10 :1437-1443