A non-invasive wearable sweat biosensor with a flexible N-GQDs/PANI nanocomposite layer for glucose monitoring

被引:41
|
作者
Lin, Yu-Chi [1 ]
Rinawati, Mia [1 ]
Chang, Ling-Yu [2 ]
Wang, Yu-Xuan [1 ]
Wu, Yu-Ting [1 ]
Yen, Yi-Han [3 ]
Chen, Kuan-Jung [3 ]
Ho, Kuo-Chuan [2 ]
Yeh, Min-Hsin [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Chem Engn, Taipei 10607, Taiwan
[2] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
[3] Mighty Elect Co Ltd, Hsinchu, Taiwan
关键词
Enzymatic; Glucose; Graphene quantum dots; Polyaniline; Sweat; Wearable biosensor; GRAPHENE QUANTUM DOTS; ELECTROCHEMICAL SENSORS; CARBON NANOTUBES; POLYANILINE; PHOTOLUMINESCENCE; COMPOSITES; ELECTRODE; SULFUR; ORIGIN;
D O I
10.1016/j.snb.2023.133617
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Understanding the levels change in biomarkers over time, especially glucose, is crucial for diabetics to inform early therapy. Recently, wearable sweat biosensors which operate in a non-invasive way have raised attention, providing continuous monitoring of the severity level. Nevertheless, the key challenges are that multiplexed motions may result in undesirable metal cracking by the rigid electrocatalytic layer, leading to decreased sensitivity and stability. In this work, we designed an N-GQDs anchored PANI matrix to realize flexible wearable biosensors with high detection accuracy. Upon the enhanced electron transfer by N-GQDs, N-GQDs/PANI nanocomposite offers greater sensitivity in H2O2 detection compared to pristine PANI, resulting in a sensitivity of 68.1 +/- 1.11 and 44.06 +/- 2.1 mu A mM-1 cm-2, respectively. Moreover, after the glucose oxidase (GOx) immo-bilization, GOx/N-GQDs/PANI-based biosensors had shown excellent performance for glucose detection in artificial sweat. Precise glucose detection was also maintained after integrating into a flexible electrode, the sensitivity of the GOx/N-GQDs/PANI-based biosensor had retained 93.2 % with no apparent cracks in the morphology of the nanocomposite layer, compared to GOx/Pt-based one (71.3 %) toward glucose detection after a continuous bending test. Thus, the N-GQDs/PANI nanocomposite layer can provide reliable long-term moni-toring with robust electrodes for non-invasive human sweat glucose monitoring on a wearable biosensor.
引用
收藏
页数:10
相关论文
共 16 条
  • [1] Carbon Nitride Quantum Dots/Polyaniline Nanocomposites for Non-Invasive Glucose Monitoring Using Wearable Sweat Biosensor
    Chiu, Yi-Hao
    Rinawati, Mia
    Chang, Ling-Yu
    Guo, Yi-Ting
    Chen, Kuan-Jung
    Chiu, Hsiang-Chih
    Lin, Zong-Hong
    Huang, Wei-Hsiang
    Haw, Shu-Chih
    Yeh, Min-Hsin
    ACS APPLIED NANO MATERIALS, 2025, 8 (05) : 2340 - 2351
  • [2] Development of Sweat and Saliva Glucose Sensors as Alternative for Non-Invasive Blood Glucose Monitoring
    Lukito, Agrevina Ane
    Tyrayoh, Michelle
    Prasetyanto, Eko Adi
    Rukmini, Elisabeth
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2024, 15 (03) : 720 - 731
  • [3] Self-powered triboelectric sensor with N-doped graphene quantum dots decorated polyaniline layer for non-invasive glucose monitoring in human sweat
    Chang, Yu-Hsin
    Chang, Ching-Cheng
    Chang, Ling-Yu
    Wang, Pang-Chen
    Kanokpaka, Pawisa
    Yeh, Min-Hsin
    NANO ENERGY, 2023, 112
  • [4] Coral-like Ti3C2Tx/PANI Binary Nanocomposite Wearable Enzyme Electrochemical Biosensor for Continuous Monitoring of Human Sweat Glucose
    Wang, Jinhao
    Chen, Lijuan
    Chen, Fan
    Lu, Xinyang
    Li, Xuanye
    Bao, Yu
    Wang, Wei
    Han, Dongxue
    Niu, Li
    CHEMOSENSORS, 2024, 12 (11)
  • [5] Non-invasive alcohol biosensor based on gold nanoparticles and carbon nanotubes network for dynamic monitoring of sweat alcohol
    Peng, Wenjing
    Li, Shan
    Gao, Hui
    Su, Mengjie
    Zhou, Yaqiu
    Ding, Zhengyuan
    Jiang, Qiyu
    Yu, Chunmei
    BIOELECTROCHEMISTRY, 2025, 164
  • [6] Non-invasive wearable electrochemical sensors for continuous glucose monitoring
    Ameen, Sameera Sh. Mohammed
    Omer, Khalid M.
    Mansour, Fotouh R.
    Bedair, Alaa
    Hamed, Mahmoud
    ELECTROCHEMISTRY COMMUNICATIONS, 2025, 173
  • [7] Microfluidic-Based Non-Invasive Wearable Biosensors for Real-Time Monitoring of Sweat Biomarkers
    Pour, Seyedeh Rojin Shariati
    Calabria, Donato
    Emamiamin, Afsaneh
    Lazzarini, Elisa
    Pace, Andrea
    Guardigli, Massimo
    Zangheri, Martina
    Mirasoli, Mara
    BIOSENSORS-BASEL, 2024, 14 (01):
  • [8] Microwave Assisted Non-invasive Microfluidic Biosensor for Monitoring Glucose Concentration
    Mondal, Debasish
    Tiwari, Nilesh Kumar
    Akhtar, M. Jaleel
    2018 IEEE SENSORS, 2018, : 1553 - 1556
  • [9] Non-Invasive, Non-Enzymatic, Biodegradable and Flexible Sweat Glucose Sensor and Its Electrochemical Studies
    Ramadoss, Preethi
    Rahman, Mohammed Isfahur
    Perumal, Agilan
    Nallaiyan, Rajendran
    Basha, Sabiha Hayath
    Dakshanamoorthy, Arivuoli
    CHEMISTRYSELECT, 2020, 5 (36): : 11305 - 11321
  • [10] Graphene electrochemical transistor incorporated with gel electrolyte for wearable and non-invasive glucose monitoring
    Gao, Nan
    Zhou, Rui
    Tu, Bo
    Tao, Tian
    Song, Yongqiao
    Cai, Zhiwei
    He, Hanping
    Chang, Gang
    Wu, Yuxiang
    He, Yunbin
    ANALYTICA CHIMICA ACTA, 2023, 1239