A Minimal Sensor Inertial Measurement Unit System Is Replicable and Capable of Estimating Bilateral Lower-Limb Kinematics in a Stationary Bodyweight Squat and a Countermovement Jump

被引:3
|
作者
Fain, AuraLea [1 ,2 ]
Hindle, Benjamin [3 ]
Andersen, Jordan [1 ,2 ]
Nindl, Bradley C. [4 ,5 ]
Bird, Matthew B. [4 ]
Fuller, Joel T. [1 ,2 ]
Wills, Jodie A. [1 ,2 ]
Doyle, Tim L. A. [1 ,2 ]
机构
[1] Macquarie Univ, Biomech Phys Performance & Exercise BioPPEx Res Gr, Sydney, NSW, Australia
[2] Macquarie Univ, Fac Med Hlth & Human Sci, Sydney, NSW, Australia
[3] Bond Univ, Fac Hlth Sci & Med, Gold Coast, Qld, Australia
[4] Univ Pittsburgh, Warrior Performance Ctr, Neuromuscular Res Lab, Pittsburgh, PA USA
[5] Univ Pittsburgh, Dept Sports Med, Pittsburgh, PA USA
关键词
wearables; algorithm development; joint angles; ANKLE KINEMATICS; KNEE MECHANICS; HIP; MOTION; ACCURACY; RANGE; PARAMETERS; SPORT; SEX;
D O I
10.1123/jab.2022-0168
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to validate a 7-sensor inertial measurement unit system against optical motion capture to estimate bilateral lower -limb kinematics. Hip, knee, and ankle sagittal plane peak angles and range of motion (ROM) were compared during bodyweight squats and countermovement jumps in 18 participants. In the bodyweight squats, left peak hip flexion (intraclass correlation coefficient [ICC] = .51), knee extension (ICC = .68) and ankle plantar flexion (ICC = .55), and hip (ICC = .63) and knee (ICC = .52) ROM had moderate agreement, and right knee ROM had good agreement (ICC = .77). Relatively higher agreement was observed in the countermovement jumps compared to the bodyweight squats, moderate to good agreement in right peak knee flexion (ICC = .73), and right (ICC = .75) and left (ICC = .83) knee ROM. Moderate agreement was observed for right ankle plantar flexion (ICC = .63) and ROM (ICC = .51). Moderate agreement (ICC > .50) was observed in all variables in the left limb except hip extension, knee flexion, and dorsiflexion. In general, there was poor agreement for peak flexion angles, and at least moderate agreement for joint ROM. Future work will aim to optimize methodologies to increase usability and confidence in data interpretation by minimizing variance in system-based differences and may also benefit from expanding planes of movement.
引用
收藏
页码:42 / 53
页数:12
相关论文
共 5 条
  • [1] Validity of an inertial measurement system to measure lower-limb kinematics in patients with hip and knee pathology
    Wang, Junqing
    Xu, Fashu
    Zhang, Hui
    Wang, Biao
    Deng, Tao
    Zhou, Zongke
    Li, Kang
    Nie, Yong
    JOURNAL OF BIOMECHANICS, 2025, 178
  • [2] Tracking Bilateral Lower Limb Kinematics of Distance Runners on Treadmill Using a Single Inertial Measurement Unit
    Patra, Yuvraj
    Liu, Qi
    Chan, Rosa H. M.
    Thomson, Daniel
    Chow, Daniel H. K.
    Fuller, Ben
    Cheung, Roy T. H.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [3] Validity of an Inertial Measurement Unit System to Measure Lower Limb Kinematics at Point of Contact during Incremental High-Speed Running
    Wolski, Lisa
    Halaki, Mark
    Hiller, Claire E.
    Pappas, Evangelos
    Yan, Alycia Fong
    SENSORS, 2024, 24 (17)
  • [4] Errors in Estimating Lower-Limb Joint Angles and Moments during Walking Based on Pelvic Accelerations: Influence of Virtual Inertial Measurement Unit's Frontal Plane Misalignment
    Inai, Takuma
    Kobayashi, Yoshiyuki
    Sudo, Motoki
    Yamashiro, Yukari
    Ueda, Tomoya
    SENSORS, 2024, 24 (16)
  • [5] Accuracy Validation of a Sensor-Based Inertial Measurement Unit and Motion Capture System for Assessment of Lower Limb Muscle Strength in Older Adults-A Novel and Convenient Measurement Approach
    Zhu, Ye
    Li, Haojie
    Wu, Xie
    Chen, Nan
    SENSORS, 2024, 24 (18)