Development of a universal sol-gel sorbent for fabric phase sorptive extraction and its application in tandem with high performance liquid chromatography-ultraviolet detection for the analysis of phthalates in environmental and drinking water samples

被引:5
|
作者
Olayanju, Basit [1 ]
Kabir, Abuzar [1 ]
Furton, Kenneth G. [1 ]
机构
[1] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
关键词
Universal sorbent; Fabric Phase Sorptive Extraction; Phthalates; Green Analytical Chemistry; ESTERS; MICROEXTRACTION; FUTURE; MILK; UV;
D O I
10.1016/j.microc.2023.109619
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Most sorbent-based sample preparation methods are designed to interact with a class of analytes i.e., a polar sorbent for polar analytes, a non -polar sorbent for non -polar analytes, an ion-exchange sorbent for ionized compounds. A big challenge surfaces when making a choice of an appropriate sorbent when there is a mixture of compounds of varying polarities and ionization states in the complex sample matrices. Hence, the aim of this study was to develop a universal sol-gel sorbent coating for fabric phase sorptive extraction that would effectively and simultaneously extract polar, nonpolar, organic acids and bases via different intermolecular/interionic interactions. The universal sol-gel sorbent coated fabric phase sorptive extraction membrane was created by exploiting sol-gel surface coating technology to implant different functional moieties, ion exchanging ligands and an organic polymer that results in a 3-D organic-inorganic hybrid structure on the fabric substrate with a high level of selectivity/affinity for the target compounds. The preconcentrated extracts containing the isolated phthalates after the fabric phase sorptive extraction procedure were injected into the high -performance liquid chromatography-ultraviolet detection (HPLC-UV) system for the quantification. The FPSE-HPLC-UV method demonstrated a linear range between 50 and 1000 ng/mL for dimethyl phthalate, diethyl phthalate, dipropyl phthalate, diallyl phthalate, benzyl butyl phthalate, 1-10000 ng/mL for di-n-heptyl phthalate, 1-5000 ng/mL for di-n-heptyl phthalate, 10-5000 ng/mL for di-n-ethyl hexyl phthalate and 100-7500 ng/mL di-n-octyl phthalate. The intra-day and inter-day reproducibility (in terms of percentage relative standard deviation, %RSD) did not exceed 13.6. This method proves to be a selective, accurate, reproducible, cheap, and fast analytical approach for the quantitative and qualitative determination of the phthalates which is useful in crafting regulations for phthalates content in beverages and juices as well as in environmental monitoring.
引用
收藏
页数:11
相关论文
共 33 条
  • [31] Optimized three-phase hollow fiber liquid-phase automated microextraction and its application in ultra-trace analysis of three pyrethroids in water and fruit samples using high-performance liquid chromatography-diode array detection
    Nikdel, Mohsen
    Nezami, Alireza
    Yamini, Yadollah
    Nezhad, Behnam Ghorbani
    Nazaripour, Ali
    Baghani, Matin
    Rahimzadegan, Milad
    SEPARATION SCIENCE PLUS, 2024, 7 (03)
  • [32] Development of water-compatible molecularly imprinted solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry for the detection of six sulfonamides in animal-derived foods
    Zhao, Xiaolei
    Wang, Junying
    Wang, Junping
    Wang, Shuo
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1574 : 9 - 17
  • [33] Core-shell polydopamine magnetic nanoparticles as sorbent in micro-dispersive solid-phase extraction for the determination of estrogenic compounds in water samples prior to high-performance liquid chromatography-mass spectrometry analysis
    Socas-Rodriguez, Barbara
    Hernandez-Borges, Javier
    Salazar, Pedro
    Martin, Miriam
    Angel Rodriguez-Delgado, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1397 : 1 - 10