Voltammetric sensor for an anti-cancer drug cisplatin based on bismuth nanoparticles/graphene modified glassy carbon electrode

被引:7
|
作者
Khumngern, Suntisak [1 ,2 ]
Choosang, Jittima [1 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,3 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Ctr Excellence Trace Anal & Biosensor, Hat Yai 90110, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Div Phys Sci, Hat Yai 90110, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90110, Songkhla, Thailand
关键词
Cisplatin; Bismuth nanoparticles; Graphene; Voltammetry; Anti -cancer drug; ANODIC-STRIPPING VOLTAMMETRY; FILM ELECTRODE; HEAVY-METALS; CONTAMINATION; LEAD; CARBOPLATIN; MECHANISMS; CADMIUM; PLASMA; PB(II);
D O I
10.1016/j.talanta.2023.125147
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and sensitive voltammetric sensor for the measurement of the chemotherapy drug cisplatin was based on bismuth nanoparticles decorated on a graphene-modified glassy carbon electrode (BiNPs/Gr/GCE). The surface morphologies of electrode modifications were characterized using scanning electron microscopy (SEM). Electrochemical characteristics were evaluated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Differential pulse voltammetry (DPV) was employed to detect cisplatin oxidation. Under the optimal conditions, oxidation peak currents increased linearly with cisplatin concentration from 6.0 to 180 mu M. The detection limit was calculated to be 4.4 mu M and the limit of quantification was 14.7 mu M. Analytical performance studies demonstrated the good electrode reproducibility and the selectivity of the BiNPs/Gr/GCE towards cisplatin detection. The developed cisplatin sensor was successfully utilized to measure cisplatin in samples of human serum. Recoveries ranged from 89 to 102% and the results from the developed sensor were concordant (P > 0.05) with the results of analysis by high-performance liquid chromatography coupled with ultraviolet detection.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A novel voltammetric sensor based on graphene quantum dots-thionine/nano-porous glassy carbon electrode for detection of cisplatin as an anti-cancer drug
    Gholivand, Mohammad Bagher
    Ahmadi, Elahe
    Mavaei, Maryamosadat
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 299
  • [2] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182
  • [3] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [4] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [5] A novel voltammetric sensor based on palladium nanoparticles/carbon nanofibers/ionic liquid modified carbon paste electrode for sensitive determination of anti-cancer drug pemetrexed
    Afzali, Moslem
    Mostafavi, Ali
    Nekooie, Reyhaneh
    Jahromi, Zahra
    JOURNAL OF MOLECULAR LIQUIDS, 2019, 282 : 456 - 465
  • [6] A sensitive bisphenol A voltammetric sensor relying on AuPd nanoparticles/graphene composites modified glassy carbon electrode
    Su, Bingyuan
    Shao, Huilin
    Li, Na
    Chen, Xiaomei
    Cai, Zhixiong
    Chen, Xi
    TALANTA, 2017, 166 : 126 - 132
  • [7] A sensitive voltammetric sensor for taxifolin based on graphene nanosheets with certain orientation modified glassy carbon electrode
    Wang, Fei
    Wu, Yanju
    Lu, Kui
    Ye, Baoxian
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 188 - 194
  • [8] Voltammetric determination of sumatriptan based on a graphene/gold nanoparticles/Nafion composite modified glassy carbon electrode
    Sanghavi, Bankim J.
    Kalambate, Pramod K.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    TALANTA, 2014, 120 : 1 - 9
  • [9] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [10] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984