Thermal induced deflection in atomic force microscopy cantilevers: analysis & solution

被引:2
|
作者
Mordue, Christopher W. [1 ]
Weaver, Jonathan M. R. [1 ]
Dobson, Phillip S. [1 ]
机构
[1] Univ Glasgow, James Watt Sch Engn, Glasgow, Scotland
基金
英国工程与自然科学研究理事会;
关键词
atomic force microscopy; thermal drift; artefacts; thermal bend; bimetallic effect; scanning thermal microscopy; TEMPERATURE; CALIBRATION; DRIFT;
D O I
10.1088/1361-6501/acf061
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Atomic force microscopy (AFM) cantilevers are commonly made from two material layers: a reflective coating and structural substrate. Although effective, this can result in thermally induced cantilever deflection due to ambient and local temperature changes. While this has been previously documented, key aspects of this common phenomenon have been overlooked. This work explores the impact of thermally induced cantilever deflection when in- and out-of-contact, including the topographic scan artefacts produced. Scanning thermal microscopy probes were employed to provide direct cantilever temperature measurement from Peltier and microheater sources, whilst permitting cantilever deflection to be simultaneously monitored. Optical lever-based measurements of thermal deflection in the AFM were found to vary by up to 250% depending on the reflected laser spot location on the cantilever. This highlights AFM's inherent inability to correctly measure and account for thermal induced cantilever deflection in its feedback system. This is particularly problematic when scanning a tip in-contact with the surface, when probe behaviour is closer mechanically to that of a bridge than a cantilever regarding thermal bending. In this case, measurements of cantilever deflection and inferred surface topography contained significant artefacts and varied from negative to positive for different optical lever laser locations on the cantilevers. These topographic errors were measured to be up to 600 nm for a small temperature change of 2 K. However, all cantilevers measured showed a point of consistent, complete thermal deflection insensitivity 55% to 60% along their lengths. Positioning the reflected laser at this location, AFM scans exhibited improvements of up-to 97% in thermal topographic artefacts relative to other laser positions.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] A method for determining the spring constant of cantilevers for atomic force microscopy
    Torii, A
    Sasaki, M
    Hane, K
    Okuma, S
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (02) : 179 - 184
  • [32] Comparison of calibration methods for atomic-force microscopy cantilevers
    Burnham, NA
    Chen, X
    Hodges, CS
    Matei, GA
    Thoreson, EJ
    Roberts, CJ
    Davies, MC
    Tendler, SJB
    NANOTECHNOLOGY, 2003, 14 (01) : 1 - 6
  • [33] Cleaning of cantilevers for atomic force microscopy in supercritical carbon dioxide
    Timashev, P. S.
    Kotova, S. L.
    Glagolev, N. N.
    Aksenova, N. A.
    Solovieva, A. B.
    Bagratashvili, V. N.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B, 2014, 8 (08) : 1081 - 1086
  • [34] Detection of microviscosity by using uncalibrated atomic force microscopy cantilevers
    Papi, Massimiliano
    Maulucci, Giuseppe
    Arcovito, Giuseppe
    Paoletti, Paolo
    Vassalli, Massimo
    De Spirito, Marco
    APPLIED PHYSICS LETTERS, 2008, 93 (12)
  • [35] A Systematic Method for Developing Harmonic Cantilevers for Atomic Force Microscopy
    Zhu, Benliang
    Zimmermann, Soren
    Zhang, Xianmin
    Fatikow, Sergej
    JOURNAL OF MECHANICAL DESIGN, 2017, 139 (01)
  • [36] LASER THERMAL EFFECTS ON ATOMIC FORCE MICROSCOPE CANTILEVERS
    ALLEGRINI, M
    ASCOLI, C
    BASCHIERI, P
    DINELLI, F
    FREDIANI, C
    LIO, A
    MARIANI, T
    ULTRAMICROSCOPY, 1992, 42 : 371 - 378
  • [37] Magnetostriction-driven cantilevers for dynamic atomic force microscopy
    Penedo, M.
    Fernandez-Martinez, I.
    Costa-Kraemer, J. L.
    Luna, M.
    Briones, F.
    APPLIED PHYSICS LETTERS, 2009, 95 (14)
  • [38] Cleaning of cantilevers for atomic force microscopy in supercritical carbon dioxide
    P. S. Timashev
    S. L. Kotova
    N. N. Glagolev
    N. A. Aksenova
    A. B. Solovieva
    V. N. Bagratashvili
    Russian Journal of Physical Chemistry B, 2014, 8 : 1081 - 1086
  • [39] Improving tapping mode atomic force microscopy with piezoelectric cantilevers
    Rogers, B
    Manning, L
    Sulchek, T
    Adams, JD
    ULTRAMICROSCOPY, 2004, 100 (3-4) : 267 - 276
  • [40] Simultaneous Scanning Ion Conductance Microscopy and Atomic Force Microscopy with Microchanneled Cantilevers
    Ossola, Dario
    Dorwling-Carter, Livie
    Dermutz, Harald
    Behr, Pascal
    Voeroes, Janos
    Zambelli, Tomaso
    PHYSICAL REVIEW LETTERS, 2015, 115 (23)