Simulation of radon detection efficiency with small pulse ionization chamber based on Geant4

被引:0
作者
Gou, Rui [1 ]
Shi, Rui [1 ]
Zhang, Qian [1 ]
Dong, Xiang-Long [2 ]
机构
[1] Sichuan Univ Sci & Engn, Yibin 644005, Sichuan, Peoples R China
[2] Hunan Commun Engn Polytech, Changsha 410000, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Pulsed ionization chamber; Radon; Detection efficiency; Monte Carlo simulation; Geant4;
D O I
10.1016/j.apradiso.2023.111152
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Radon measurement is crucial in assessing the damage to the human body caused by natural radiation. Pulsed ionization chambers are effective for real-time radon measurement and have widespread applications in other radiation techniques. However, due to practical constraints such as limited space and portability concerns, it becomes imperative to consider not only the detection efficiency but also their ease of transportation. This work utilizes the Geant4 Monte Carlo simulation toolkit to characterize the detection models of small cylindrical and flat plate-type pulsed ionization chambers, and carry out a simulation study to analyze the three crucial factors that influence detection efficiency, including the geometry of the chamber, electrode size, and operating temperature. The results indicate that the cylindrical pulse ionization chamber, with a length of 8 cm and radius of 2 cm, has the best detection efficiency and portability in terms of geometric dimensions, achieving a detection efficiency of (58 +/- 4)%. Meanwhile, the flat plate pulse ionization chamber, with dimensions of 7 cm in length and 3 cm in width, achieves the best detection efficiency and portability, with a detection efficiency of (54 +/- 3)%. In terms of electrode wire size, the cylindrical ionization chamber electrode wire with a length of 7 cm and a radius of 2.5 mm was optimal with a detection efficiency of (59 +/- 4)%. In terms of operating temperature, the detection efficiency of the flat-plate pulsed ionization chamber was the highest at 30 degrees C, which was (58 +/- 4)%, and that of the cylindrical pulsed ionization chamber was the highest at 20 degrees C, which was (63 +/- 4)%. By analyzing the influencing factors of the detection efficiency of the pulsed ionization chamber, it has a certain reference value and guiding significance for the research and design of small pulsed ionization chamber detectors for radon measuring instruments.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Geant4 simulation of plastic scintillators for a prototype μSR spectrometer
    XU Wenzhen
    LIU Yanfen
    TAN Zongquan
    XIAO Ran
    KONG Wei
    YE Bangjiao
    Nuclear Science and Techniques, 2013, 24 (04) : 52 - 58
  • [22] Photon Elastic Scattering Simulation: Validation and Improvements to Geant4
    Batic, Matej
    Hoff, Gabriela
    Pia, Maria Grazia
    Saracco, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1636 - 1664
  • [23] Recent progress of Geant4 electromagnetic physics for calorimeter simulation
    Incerti, S.
    Ivanchenko, V.
    Novak, M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [24] GEANT4 Simulation for Radioactive Particle Tracking (RPT) Technique
    Alghamdi, Ahmed A.
    Aljuwaya, Thaar M.
    Alomari, Abdullah S.
    Al-Dahhan, Muthanna H.
    SENSORS, 2022, 22 (03)
  • [25] Geant4 simulation of plastic scintillators for a prototype μSR spectrometer
    Xu Wenzhen
    Liu Yanfen
    Tan Zongquan
    Xiao Ran
    Kong Wei
    Ye Bangjiao
    NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (04)
  • [26] Geant4 Monte Carlo radioxenon beta-gamma coincidence efficiency simulation for a phoswich detector
    Weihua Zhang
    Pawel Mekarski
    Jonathan Lam
    Kurt Ungar
    Eric Pellerin
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 285 : 475 - 482
  • [27] Geant4 Monte Carlo radioxenon beta-gamma coincidence efficiency simulation for a phoswich detector
    Zhang, Weihua
    Mekarski, Pawel
    Lam, Jonathan
    Ungar, Kurt
    Pellerin, Eric
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 285 (03) : 475 - 482
  • [28] GEANT4 code for simulation of a germanium gamma-ray detector and its application to efficiency calibration
    Hurtado, S
    García-León, M
    García-Tenorio, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (03) : 764 - 774
  • [29] Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
    Arce, P.
    Bolst, D.
    Bordage, M-c
    Brown, J. M. C.
    Cirrone, P.
    Cortes-Giraldo, M. A.
    Cutajar, D.
    Cuttone, G.
    Desorgher, L.
    Dondero, P.
    Dotti, A.
    Faddegon, B.
    Fedon, C.
    Guatelli, S.
    Incerti, S.
    Ivanchenko, V
    Konstantinov, D.
    Kyriakou, I
    Latyshev, G.
    Le, A.
    Mancini-Terracciano, C.
    Maire, M.
    Mantero, A.
    Novak, M.
    Omachi, C.
    Pandola, L.
    Perales, A.
    Perrot, Y.
    Petringa, G.
    Quesada, J. M.
    Ramos-Mendez, J.
    Romano, F.
    Rosenfeld, A. B.
    Sarmiento, L. G.
    Sakata, D.
    Sasaki, T.
    Sechopoulos, I
    Simpson, E. C.
    Toshito, T.
    Wright, D. H.
    MEDICAL PHYSICS, 2021, 48 (01) : 19 - 56
  • [30] Simulation of the response of the IG11 4πγ ionization chamber using GEANT Monte Carlo code