Simulation of radon detection efficiency with small pulse ionization chamber based on Geant4

被引:0
|
作者
Gou, Rui [1 ]
Shi, Rui [1 ]
Zhang, Qian [1 ]
Dong, Xiang-Long [2 ]
机构
[1] Sichuan Univ Sci & Engn, Yibin 644005, Sichuan, Peoples R China
[2] Hunan Commun Engn Polytech, Changsha 410000, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Pulsed ionization chamber; Radon; Detection efficiency; Monte Carlo simulation; Geant4;
D O I
10.1016/j.apradiso.2023.111152
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Radon measurement is crucial in assessing the damage to the human body caused by natural radiation. Pulsed ionization chambers are effective for real-time radon measurement and have widespread applications in other radiation techniques. However, due to practical constraints such as limited space and portability concerns, it becomes imperative to consider not only the detection efficiency but also their ease of transportation. This work utilizes the Geant4 Monte Carlo simulation toolkit to characterize the detection models of small cylindrical and flat plate-type pulsed ionization chambers, and carry out a simulation study to analyze the three crucial factors that influence detection efficiency, including the geometry of the chamber, electrode size, and operating temperature. The results indicate that the cylindrical pulse ionization chamber, with a length of 8 cm and radius of 2 cm, has the best detection efficiency and portability in terms of geometric dimensions, achieving a detection efficiency of (58 +/- 4)%. Meanwhile, the flat plate pulse ionization chamber, with dimensions of 7 cm in length and 3 cm in width, achieves the best detection efficiency and portability, with a detection efficiency of (54 +/- 3)%. In terms of electrode wire size, the cylindrical ionization chamber electrode wire with a length of 7 cm and a radius of 2.5 mm was optimal with a detection efficiency of (59 +/- 4)%. In terms of operating temperature, the detection efficiency of the flat-plate pulsed ionization chamber was the highest at 30 degrees C, which was (58 +/- 4)%, and that of the cylindrical pulsed ionization chamber was the highest at 20 degrees C, which was (63 +/- 4)%. By analyzing the influencing factors of the detection efficiency of the pulsed ionization chamber, it has a certain reference value and guiding significance for the research and design of small pulsed ionization chamber detectors for radon measuring instruments.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] GEANT4 modeling of alpha particles detection efficiency for polycarbonate SSNTD
    Moslehi, A.
    Baradaran, S.
    Taheri, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1033
  • [2] Introduction to the Geant4 Simulation toolkit
    Guatelli, S.
    Cutajar, D.
    Oborn, B.
    Rosenfeld, A. B.
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 303 - 322
  • [3] GEANT4 simulation of gamma ray in a double-gap resistive plate chamber
    Rhee, JT
    Jamil, M
    Hall, S
    Jeon, YJ
    CHINESE PHYSICS, 2006, 15 (01): : 108 - 115
  • [4] A sourceless efficiency calibration model of airborne γ-spectrometry based on Geant4
    Mei, Cong
    Fu, Chen
    Zhang, Wei
    Li, Jiangkun
    Liang, Xudong
    Wu, Xue
    Luo, Qibin
    Yang, Yaxin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (08)
  • [5] SIMULATION RESPONSE OF RESISTIVE PLATE CHAMBER FOR FAST NEUTRONS USING GEANT4 MC CODE
    Jamil, M.
    Rhee, J. T.
    Jo, H. Y.
    Ahmad, Farzana
    Jeon, Y. J.
    ROMANIAN JOURNAL OF PHYSICS, 2012, 57 (9-10): : 1329 - 1334
  • [6] Radioxenon beta-gamma coincidence efficiency for a SAUNA detector by Geant4 simulation
    Zahran, I
    Ababneh, E.
    Okoor, S.
    Albqoor, A.
    PHYSICA SCRIPTA, 2024, 99 (10)
  • [7] Multi-threaded Geant4 simulation for the layman
    Han, Min Cheol
    Pia, Maria Grazia
    Ronchieri, Elisabetta
    Saracco, Paolo
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] Simulation of the ROT-Effect Using GEANT4
    M. Yu. Kopatch
    Yu. N. Kopatch
    V. L. Kuznetsov
    Physics of Particles and Nuclei Letters, 2025, 22 (2) : 345 - 348
  • [10] Investigation of electrons inside the satellite by the Geant4 simulation
    Li XiaoCan
    Chen HongFei
    Hao YongQiang
    Zou Hong
    Shi WeiHong
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (09) : 2271 - 2275